thyristor can be turned off by?
Show More Ask Question

1 Answer

Answer :

Thyristor can be turned off by making anode potential equal to cathode potential or by making anode potential less than cathode potential.
Like 0 like
Next Page →

Related

Description : The SCR would be turned OFF by voltage reversal of applied anode-cathode ac supply frequency of A) 10 kHz B) 10 Hz C) 5 kHz D) 5 Hz 

Description : How is the GTO turned off? A) By using a commutation circuit B) By applying reverse gate pulse C) By using a latch-up circuit D) By reverse anode current pulse 

Answer : How is the GTO turned off? A) By using a commutation circuit B) By applying reverse gate pulse C) By using a latch-up circuit D) By reverse anode current pulse 

Answer : SCR turned off when the anode current falls below holding current.

Answer : No we cannot turn off normal thyristor using Gate.

Description : Draw the structural diagram of GTO. Explain briefly the switching behavior of GTO with the help of appropriate voltage and current waveform.

Answer : Gate Turn Off Thyristor (GTO) Conventional Thyristor can be turned on with gate terminal but can not turn off from gate terminal. But in case of Gate Turn Off Thyristor (GTO), we can turn it on and off ... subdivided as storage period (Ts), fall period (Tp) and tail period (Tt).