menu search
person
thumb_up_alt 0 like thumb_down_alt 0 dislike
93 views

1 Answer

The armature core of a D.C. generator is usually made of silicon steel.

thumb_up_alt 0 like thumb_down_alt 0 dislike
← Prev Question Next Question →

Related questions

Description :

Answer :

The demagnetising component of armature reaction in a D.C. generator reduces generator e.m.f.

thumb_up_alt 0 like thumb_down_alt 0 dislike
82 views 1 answer
thumb_up_alt 0 like thumb_down_alt 0 dislike
193 views 0 answers
Description :

A 200 V DC machine supplies 20 A at 200 V as a generator. The armature resistance is 0.2 Ohm. If the machine is now operated as a motor at same terminal voltage and current but with the flux increased by 10%, the ratio of motor speed to generator speed is

Answer :

A 200 V DC machine supplies 20 A at 200 V as a generator. The armature resistance is 0.2 Ohm. If the machine is now operated as a motor at same terminal voltage and current but with the flux increased by 10%, the ratio of motor speed to generator speed is 0.87

thumb_up_alt 0 like thumb_down_alt 0 dislike
81 views 1 answer
Description :

Why is the armature of DC generator laminated?

Answer :

The armature of DC generator is laminated to reduce eddy current losses.

thumb_up_alt 0 like thumb_down_alt 0 dislike
155 views 1 answer
Description :

Answer :

Armature reaction in a generator results in demagnetisation of leading pole tip and magnetisation of trailing pole tip.

thumb_up_alt 0 like thumb_down_alt 0 dislike
90 views 1 answer
Description :

Answer :

A sinusoidal voltage of 5 Hz is applied to the field of a shunt generator. The armature voltage wave will be of 5 Hz.

thumb_up_alt 0 like thumb_down_alt 0 dislike
141 views 1 answer
Description :

For a D.C. generator when the number of poles and the number of armature conductors is fixed, then which winding will give the higher e.m.f. ?

Answer :

Wave winding

thumb_up_alt 0 like thumb_down_alt 0 dislike
96 views 1 answer
Description :

Answer :

Open circuited armature coil of a D.C. machine is identified by the scarring of the commutator segment to which open circuited coil is connected and indicated by a spark completely around the commutator.

thumb_up_alt 0 like thumb_down_alt 0 dislike
140 views 1 answer
Description :

The armature reaction in a synchronous generator supplying leading power factor load is (A) magnetizing (B) demagnetizing (C) demagnetizing and cross-magnetizing (D) magnetizing and cross-magnetizing

Answer :

The armature reaction in a synchronous generator supplying leading power factor load is magnetizing and cross-magnetizing

thumb_up_alt 0 like thumb_down_alt 0 dislike
56 views 1 answer
Description :

In DC generators lamination core are generally made of?

Answer :

In DC generators lamination core are generally made of silicon steel.

thumb_up_alt 0 like thumb_down_alt 0 dislike
162 views 1 answer
Description :

If residual magnetism is present in a D.C. generator, the induced e.m.f. at zero speed will be?

Answer :

If residual magnetism is present in a D.C. generator, the induced e.m.f. at zero speed will be zero.

thumb_up_alt 0 like thumb_down_alt 0 dislike
223 views 1 answer
Description :

Answer :

A 220 V D.C. generator is run at full speed without any excitation. The open circuit voltage will be about 2 V.

thumb_up_alt 0 like thumb_down_alt 0 dislike
347 views 1 answer
Description :

Answer :

In a level compounded D.C. generator, full load terminal voltage is equal to no-load terminal voltage.

thumb_up_alt 0 like thumb_down_alt 0 dislike
92 views 1 answer
Description :

Answer :

In a D.C. generator in case the resistance of the field winding is increased, then output voltage will decrease.

thumb_up_alt 0 like thumb_down_alt 0 dislike
174 views 1 answer
Description :

Answer :

A D.C. generator can be considered as rotating amplifier.

thumb_up_alt 0 like thumb_down_alt 0 dislike
64 views 1 answer
Description :

Answer :

In a D.C. generator, the critical resistance refers to the resistance of field.

thumb_up_alt 0 like thumb_down_alt 0 dislike
96 views 1 answer
Description :

Answer :

If a D.C. generator fails to build up the probable cause could not be field resistance less than the critical resistance.

thumb_up_alt 0 like thumb_down_alt 0 dislike
75 views 1 answer
Description :

Answer :

In a D.C. generator the magnetic neutral axis coincides with the geometrical neutral axis, when there is no load on|he generator.

thumb_up_alt 0 like thumb_down_alt 0 dislike
159 views 1 answer
Description :

Answer :

The e.m.f. generated in a D.C. generator is directly proportional to speed of armature.

thumb_up_alt 0 like thumb_down_alt 0 dislike
394 views 1 answer
Description :

Answer :

In a D.C. generator the number of mechanical degrees and electrical degrees will be the same when number of poles is 2.

thumb_up_alt 0 like thumb_down_alt 0 dislike
627 views 1 answer
thumb_up_alt 0 like thumb_down_alt 0 dislike
81 views 0 answers
Description :

Answer :

In a D.C. generator the ripples in the direct e.m.f. generated are reduced by using carbon brushes of superior quality.

thumb_up_alt 0 like thumb_down_alt 0 dislike
139 views 1 answer
Description :

Answer :

Magnetic field in a D.C. generator is produced by electromagnets.

thumb_up_alt 0 like thumb_down_alt 0 dislike
134 views 1 answer
Description :

Answer :

If brushes of a D.C. generator are moved in order to bring these brushes in magnetic neutral axis, there will be crossmagnetisation as well as demagnetising.

thumb_up_alt 0 like thumb_down_alt 0 dislike
104 views 1 answer
Description :

Answer :

In case of a 4-pole D.C. generator provided with a two layer lap winding with sixteen coils, the pole pitch will be 8.

thumb_up_alt 0 like thumb_down_alt 0 dislike
147 views 1 answer
Description :

Answer :

In a D.C. generator, the iron losses mainly take place in armature rotor.

thumb_up_alt 0 like thumb_down_alt 0 dislike
246 views 1 answer
Description :

Answer :

The condition for maximum efficiency for a D.C. generator is variable losses equal to constant losses.

thumb_up_alt 0 like thumb_down_alt 0 dislike
171 views 1 answer
Description :

Answer :

The total losses in a well designed D.C. generator of 10 kW will be nearly 500 W.

thumb_up_alt 0 like thumb_down_alt 0 dislike
105 views 1 answer
Description :

Answer :

The critical resistance of the D.C. generator is the resistance of field.

thumb_up_alt 0 like thumb_down_alt 0 dislike
377 views 1 answer
Description :

Answer :

Flashing the field of D.C. generator means creating residual magnetism by a D.C. source.

thumb_up_alt 0 like thumb_down_alt 0 dislike
66 views 1 answer
Description :

Answer :

D.C. generator generally preferred for charging automobile batteries is long shunt compound generator.

thumb_up_alt 0 like thumb_down_alt 0 dislike
196 views 1 answer
Description :

The normal value of the armature resistance of a d.c. motor is?

Answer :

The normal value of the armature resistance of a d.c. motor is 0.5.

thumb_up_alt 0 like thumb_down_alt 0 dislike
869 views 1 answer
Description :

Answer :

When the armature of a D.C. motor rotates, e.m.f. induced is back e.m.f.

thumb_up_alt 0 like thumb_down_alt 0 dislike
121 views 1 answer
Description :

Answer :

In a D.C. shunt motor, under the conditions of maximum power, the current in the armature will be more than full-load current.

thumb_up_alt 0 like thumb_down_alt 0 dislike
221 views 1 answer
Description :

Answer :

The armature voltage control of D.C. motor provides constant torque drive.

thumb_up_alt 0 like thumb_down_alt 0 dislike
55 views 1 answer
Description :

Answer :

The armature torque of the D.C. shunt motor is proportional to armature current.

thumb_up_alt 0 like thumb_down_alt 0 dislike
105 views 1 answer
Description :

From which material field coils of DC generator are made of?

Answer :

Field coils of DC generator are usually made of copper.

thumb_up_alt 0 like thumb_down_alt 0 dislike
108 views 1 answer
Description :

Answer :

In D.C. generators on no-load, the air gap flux distribution in space is flat topped.

thumb_up_alt 0 like thumb_down_alt 0 dislike
83 views 1 answer
Description :

A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is

Answer :

A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is 36 Ohm

thumb_up_alt 0 like thumb_down_alt 0 dislike
193 views 1 answer
Description :

The induced emf in the armature of a lap -wound four -pole dc machine having 100 armature conductors rotating at 600 rpm and with 1 Wb flux per pole is  (1) 1000V (2) 100V (3) 600V (4) 10,000V

Answer :

The induced emf in the armature of a lap -wound four -pole dc machine having 100 armature conductors rotating at 600 rpm and with 1 Wb flux per pole is 1000V

thumb_up_alt 0 like thumb_down_alt 0 dislike
223 views 1 answer
Description :

Aluminium is not used as winding wire for the armature of a dc machine because  (1) aluminium has low resistivity (2) a large winding space is taken by aluminium conductors and creates jointing problems (3) the thermal conductivity of aluminium is low (4) aluminium has low conductivity as compared to copper

Answer :

Aluminium is not used as winding wire for the armature of a dc machine because  (2) a large winding space is taken by aluminium conductors and creates jointing problems (3) the thermal conductivity of aluminium is low (4) aluminium has low conductivity as compared to copper

thumb_up_alt 0 like thumb_down_alt 0 dislike
530 views 1 answer
Description :

In dc machines, the armature windings are placed on the rotor because of the necessity for  (1) electromechanical energy conversion (2) generation of voltage (3) commutation (4) development of torque

Answer :

3  Commutation

thumb_up_alt 0 like thumb_down_alt 0 dislike
212 views 2 answers
Description :

Armature control of DC motor

Answer :

Armature control of DC motor

thumb_up_alt 0 like thumb_down_alt 0 dislike
141 views 2 answers
Description :

Answer :

In a separately excited generator supplying rated load the armature reaction is always present.

thumb_up_alt 0 like thumb_down_alt 0 dislike
100 views 1 answer
Description :

The e.m.f. induced in the armature of a shunt generator is 600 V. The armature resistance is 0.1 ohm. If the armature current is 200 A, the terminal voltage will be?

Answer :

The e.m.f. induced in the armature of a shunt generator is 600 V. The armature resistance is 0.1 ohm. If the armature current is 200 A, the terminal voltage will be 580 V.

thumb_up_alt 0 like thumb_down_alt 0 dislike
414 views 1 answer
Description :

Answer :

Armature reaction of an unsaturated D.C. machine is crossmagnetising.

thumb_up_alt 0 like thumb_down_alt 0 dislike
309 views 1 answer
Description :

Answer :

Material used for construction of transformer core is usually silicon steel.

thumb_up_alt 0 like thumb_down_alt 0 dislike
141 views 1 answer
Description :

Answer :

In a A.C. series motor armature coils are usually connected to commutator through resistance.

thumb_up_alt 0 like thumb_down_alt 0 dislike
111 views 1 answer
Description :

The fall in speed of a dc generator due to increase in load can be corrected by  (1) cooling the armature.. (2) increasing the excitation. (3) reducing the load voltage. (4) increasing the input to the prime mover

Answer :

It   can  be  corrected  by  increasing  the  input  to  the  prime  mover.

thumb_up_alt 0 like thumb_down_alt 0 dislike
172 views 2 answers
Description :

The eddy current loss in a dc generator is 400 W at 40 Hz frequency of reversal and constant flux density. When frequency is increased to 50 Hz., eddy current loss is :  (A) 256 W (B) 320 W (C) 500 W (D) 625 W

Answer :

The eddy current loss in a dc generator is 400 W at 40 Hz frequency of reversal and constant flux density. When frequency is increased to 50 Hz., eddy current loss is : 625 W

thumb_up_alt 0 like thumb_down_alt 0 dislike
83 views 1 answer
editAsk a Question
...