The speed of a D.C. shunt motor can be increased by?
Speak Question
asked
Mar 20, 2018
by
anonymous
speed
dc
shunt
motor
thumb_up_alt
0
like
thumb_down_alt
0
dislike
90
views
Please
log in
or
register
to add a comment.
Please
log in
or
register
to answer this question.
1
Answer
Speak Answer
answered
Mar 20, 2018
by
anonymous
The speed of a D.C. shunt motor can be increased by
increasing the resistance in field circuit.
thumb_up_alt
0
like
thumb_down_alt
0
dislike
Please
log in
or
register
to add a comment.
← Prev Question
Next Question →
Related questions
asked
Mar 20, 2018
by
anonymous
As the load is increased the speed of D.C. shunt motor will?
Last answer:
As the load is increased the speed of D.C. shunt motor will reduce slightly.
load
increased
speed
dc
shunt
motor
thumb_up_alt
0
like
thumb_down_alt
0
dislike
106
views
1
answer
asked
Mar 20, 2018
by
anonymous
If the speed of a D.C. shunt motor is increased, the back e.m.f. of the motor will?
Last answer:
If the speed of a D.C. shunt motor is increased, the back e.m.f. of the motor will increase.
speed
dc
shunt
motor
thumb_up_alt
0
like
thumb_down_alt
0
dislike
111
views
1
answer
asked
Mar 20, 2018
by
anonymous
In a D.C. shunt motor, speed is?
Last answer:
In a D.C. shunt motor, speed is independent of armature current.
dc
shunt
motor
speed
thumb_up_alt
0
like
thumb_down_alt
0
dislike
62
views
1
answer
asked
Mar 20, 2018
by
anonymous
The speed of a D.C. shunt motor more than its full-load speed can be obtained by?
Last answer:
The speed of a D.C. shunt motor more than its full-load speed can be obtained by decreasing the field current.
dc
shunt
motor
thumb_up_alt
0
like
thumb_down_alt
0
dislike
92
views
1
answer
asked
May 8, 2018
by
anonymous
A 240 V, dc shunt motor draws 15 A while supplying the rated load at a speed of 80 rad/s.
A 240 V, dc shunt motor draws 15 A while supplying the rated load at a speed of 80 rad/s. The armature resistance is 0.5 W and the field winding resistance is 80 W. The net Voltage across armature resistance at the time of plugging will be
Last answer:
A 240 V, dc shunt motor draws 15 A while supplying the rated load at a speed of 80 rad/s. The armature resistance is 0.5 W and the field winding resistance is 80 W. The net Voltage across armature resistance at the time of plugging will be 474 V
dc
shunt
motor
rated
load
speed
thumb_up_alt
0
like
thumb_down_alt
0
dislike
229
views
1
answer
asked
Jul 5, 2019
by
anonymous
Why does the speed of a DC shunt motor decrease as the load increases?
Why does the speed of a DC shunt motor decrease as the load increases?
Last answer:
Because if the load is increasing then the torque must also be increase. If not then the speed of motor will decrease.
why
does
the
speed
of
a
dc
shunt
motor
decrease
as
load
increases
thumb_up_alt
0
like
thumb_down_alt
0
dislike
2.6k
views
1
answer
asked
Mar 20, 2018
by
anonymous
The speed of a D.C. motor can be controlled by varying
The speed of a D.C. motor can be controlled by varying 1. Its flux per pole 2. Resistance of armature circuit 3. Applied voltage 4. All of the above
Last answer:
The speed of a D.C. motor can be controlled by varying 1. Its flux per pole 2. Resistance of armature circuit 3. Applied voltage 4. All of the above
speed
dc
motor
varying
thumb_up_alt
0
like
thumb_down_alt
0
dislike
116
views
1
answer
asked
Mar 20, 2018
by
anonymous
In case of D.C. shunt motors the speed is dependent on back e.m.f. only because?
Last answer:
In case of D.C. shunt motors the speed is dependent on back e.m.f. only because flux is practically constant in D:C. shunt motors.
dc
shunt
motors
speed
back
emf
thumb_up_alt
0
like
thumb_down_alt
0
dislike
149
views
1
answer
asked
Mar 20, 2018
by
anonymous
In a D.C. shunt motor, under the conditions of maximum power, the current in the armature will be?
Last answer:
In a D.C. shunt motor, under the conditions of maximum power, the current in the armature will be more than full-load current.
dc
shunt
motor
conditions
maximum
power
current
armature
thumb_up_alt
0
like
thumb_down_alt
0
dislike
175
views
1
answer
asked
Mar 20, 2018
by
anonymous
If the field of a D.C. shunt motor gets opened while motor is running?
Last answer:
If the field of a D.C. shunt motor gets opened while motor is running the motor will attain dangerously high speed.
field
dc
shunt
motor
thumb_up_alt
0
like
thumb_down_alt
0
dislike
94
views
1
answer
asked
Mar 20, 2018
by
anonymous
For a D.C. shunt motor if the excitation is changed?
Last answer:
For a D.C. shunt motor if the excitation is changed torque will change but power will remain constant.
dc
shunt
motor
excitation
thumb_up_alt
0
like
thumb_down_alt
0
dislike
128
views
1
answer
asked
Mar 20, 2018
by
anonymous
The armature torque of the D.C. shunt motor is proportional to?
Last answer:
The armature torque of the D.C. shunt motor is proportional to armature current.
armature
torque
dc
shunt
motor
thumb_up_alt
0
like
thumb_down_alt
0
dislike
88
views
1
answer
asked
Mar 20, 2018
by
anonymous
The speed of a D.C. series motor is?
Last answer:
The speed of a D.C. series motor is inversely proportional to the armature current.
speed
series
motor
dc
thumb_up_alt
0
like
thumb_down_alt
0
dislike
71
views
1
answer
asked
Mar 20, 2018
by
anonymous
If a D.C. shunt motor is working at full load and if shunt field circuit suddenly opens?
Last answer:
If a D.C. shunt motor is working at full load and if shunt field circuit suddenly opens this will make armature to take heavy current, possibly burning it.
dc
shunt
motor
working
full
load
field
circuit
suddenly
opens
thumb_up_alt
0
like
thumb_down_alt
0
dislike
103
views
1
answer
asked
May 3, 2018
by
anonymous
A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance
A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is
Last answer:
A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is 36 Ohm
dc
shunt
motor
running
current
armature
winding
resistance
thumb_up_alt
0
like
thumb_down_alt
0
dislike
175
views
1
answer
asked
Aug 25, 2019
by
anonymous
If field current is decreased in shunt dc motor, the speed of the motor
If field current is decreased in shunt dc motor, the speed of the motor (a) remains same. (b) increases. (c) decreases. (d) none of the above.
Last answer:
increases
shunt
dc
motor
thumb_up_alt
0
like
thumb_down_alt
0
dislike
1.6k
views
4
answers
asked
Dec 16, 2017
by
anonymous
What are the speed control methods of dc motor?
What are the speed control methods of dc motor?
Last answer:
Field control of DC motor Armature control of DC motor
speed
control
methods
dc
motor
thumb_up_alt
3
like
thumb_down_alt
0
dislike
150
views
2
answers
asked
Mar 20, 2018
by
anonymous
The mechanical power developed by a shunt motor will be maximum when the ratio of back e.m.f. to applied voltage is?
Last answer:
The mechanical power developed by a shunt motor will be maximum when the ratio of back e.m.f. to applied voltage is 0.5.
mechanical
power
shunt
motor
maximum
ratio
back
emf
voltage
thumb_up_alt
0
like
thumb_down_alt
0
dislike
146
views
1
answer
asked
Jul 27, 2019
by
anonymous
State any four applications of DC shunt motor.
State any four applications of DC shunt motor.
Last answer:
Applications of DC shunt motor: 1) Lathe machines 2) drilling machines 3) milling machines 4) Printing machinery 5) Paper industry 6) centrifugal and reciprocating pumps 7) blowers 8)fans
dc
shunt
motor
thumb_up_alt
0
like
thumb_down_alt
0
dislike
79
views
2
answers
asked
Mar 20, 2018
by
anonymous
By looking at which part of the motor, it can be easily confirmed that a particular motor is D.C. motor?
Last answer:
By looking at Commutator part of the motor, it can be easily confirmed that a particular motor is D.C. motor.
motor
dc
thumb_up_alt
0
like
thumb_down_alt
0
dislike
80
views
1
answer
asked
Mar 20, 2018
by
anonymous
The direction of rotation of a D.C. series motor can be changed by?
Last answer:
The direction of rotation of a D.C. series motor can be changed by interchanging field terminals.
direction
rotation
dc
series
motor
thumb_up_alt
0
like
thumb_down_alt
0
dislike
75
views
1
answer
asked
Apr 23, 2020
by
anonymous
DC shunt motor
DC shunt motor
Last answer:
.embed-container { position: relative; padding-bottom: 56.25%; height: 0; overflow: hidden; max-width: 100%; } .embed-container iframe, .embed-container object, .embed-container embed { position: absolute; top: 0; left: 0; width: 100%; height: 100%; }
dc
shunt
motor
thumb_up_alt
0
like
thumb_down_alt
0
dislike
108
views
2
answers
asked
May 1, 2018
by
anonymous
The fall in speed of a dc generator due to increase in load can be corrected by
The fall in speed of a dc generator due to increase in load can be corrected by (1) cooling the armature.. (2) increasing the excitation. (3) reducing the load voltage. (4) increasing the input to the prime mover
Last answer:
It can be corrected by increasing the input to the prime mover.
speed
dc
generator
thumb_up_alt
0
like
thumb_down_alt
0
dislike
159
views
2
answers
asked
Mar 20, 2018
by
anonymous
In case of a reluctance motor, when the load is increased so that it cannot maintain synchronous speed the motor will?
Last answer:
In case of a reluctance motor, when the load is increased so that it cannot maintain synchronous speed the motor will run as induction motor.
reluctance
motor
synchronous
speed
thumb_up_alt
0
like
thumb_down_alt
0
dislike
87
views
1
answer
asked
Mar 20, 2018
by
anonymous
Speed torque characteristic of a repulsion induction motor is similar to that of a D.C.?
Last answer:
Speed torque characteristic of a repulsion induction motor is similar to that of a D.C. compound motor.
speed
torque
characteristic
repulsion
induction
motor
thumb_up_alt
0
like
thumb_down_alt
0
dislike
69
views
1
answer
asked
Apr 28, 2018
by
anonymous
The no-load speed of a single-phase SCR bridge converter fed separately excited dc motor operating at a
The no-load speed of a single-phase SCR bridge converter fed separately excited dc motor operating at a firing delay angle, α and flux, Φ (A) directly proportional to α and Φ (B) inversely proportional to α and Φ (C) directly proportional to α and inversely proportional to Φ (D) directly proportional to Φ and inversely proportional to α
Last answer:
The no-load speed of a single-phase SCR bridge converter fed separately excited dc motor operating at a firing delay angle, α and flux, Φ directly proportional to α and inversely proportional to Φ
no-load
speed
single-phase
scr
bridge
converter
fed
separately
excited
dc
motor
operating
thumb_up_alt
0
like
thumb_down_alt
0
dislike
122
views
1
answer
asked
Mar 20, 2018
by
anonymous
In case the back e.m.f. and the speed of a D.C. motor are doubled, the torque developed by the motor will?
Last answer:
In case the back e.m.f. and the speed of a D.C. motor are doubled, the torque developed by the motor will remain unchanged.
dc
motor
thumb_up_alt
0
like
thumb_down_alt
0
dislike
148
views
1
answer
asked
Mar 20, 2018
by
anonymous
In D.C. shunt motors as load is reduced?
Last answer:
In D.C. shunt motors as load is reduced the speed will remain almost constant.
dc
shunt
motors
load
thumb_up_alt
0
like
thumb_down_alt
0
dislike
54
views
1
answer
asked
Mar 20, 2018
by
anonymous
The operating speed of a synchronous motor can be changed to new fixed value by?
Last answer:
The operating speed of a synchronous motor can be changed to new fixed value by changing frequency.
operating
speed
synchronous
motor
fixed
value
thumb_up_alt
0
like
thumb_down_alt
0
dislike
83
views
1
answer
asked
Mar 20, 2018
by
anonymous
In a differentially compounded D.C. motor, if shunt field suddenly opens?
Last answer:
In a differentially compounded D.C. motor, if shunt field suddenly opens the motor will first stop and then run in opposite direction as series motor.
dc
motor
thumb_up_alt
0
like
thumb_down_alt
0
dislike
70
views
1
answer
asked
Mar 20, 2018
by
anonymous
If a D.C. shunt motor is working at no load and if shunt field circuit suddenly opens?
Last answer:
If a D.C. shunt motor is working at no load and if shunt field circuit suddenly opens this will result in excessive speed, possibly destroying armature due to excessive centrifugal stresses.
dc
motor
thumb_up_alt
0
like
thumb_down_alt
0
dislike
96
views
1
answer
asked
Mar 20, 2018
by
anonymous
In a D.C. series motor, if the armature current is reduced by 50%, the torque of the motor will be equal to?
Last answer:
In a D.C. series motor, if the armature current is reduced by 50%, the torque of the motor will be equal to 25% of the previous value.
dc
motor
series
thumb_up_alt
0
like
thumb_down_alt
0
dislike
146
views
1
answer
asked
May 1, 2018
by
anonymous
The speed of a three-phase induction motor is controlled by variable voltage variable frequency control
The speed of a three-phase induction motor is controlled by variable voltage variable frequency control (i.e. keeping V/f constant). As the frequency is reduced, the slip at maximum torque (1) Decreases (2) Increases (3) Remains constant (4) None of the above
Last answer:
The speed of a three-phase induction motor is controlled by variable voltage variable frequency control (i.e. keeping V/f constant). As the frequency is reduced, the slip at maximum torque Increases
speed
three-phase
induction
motor
controlled
variable
voltage
frequency
control
thumb_up_alt
0
like
thumb_down_alt
0
dislike
119
views
1
answer
asked
Apr 28, 2018
by
anonymous
The speed of a 2-pole, 3-phase stepper motor operated by 1200 pulses/min
The speed of a 2-pole, 3-phase stepper motor operated by 1200 pulses/min (A) 100 rpm (B) 200 rpm (C) 400 rpm (D) 800 rpm
Last answer:
The speed of a 2-pole, 3-phase stepper motor operated by 1200 pulses/min 200 rpm
speed
2-pole
3-phase
stepper
motor
operated
thumb_up_alt
0
like
thumb_down_alt
0
dislike
121
views
1
answer
asked
Mar 20, 2018
by
anonymous
The speed of a universal motor is usually reduced by using?
Last answer:
The speed of a universal motor is usually reduced by using gearing.
speed
universal
motor
thumb_up_alt
0
like
thumb_down_alt
0
dislike
78
views
1
answer
asked
Mar 20, 2018
by
anonymous
Speed control of a universal motor is achieved by?
Last answer:
Speed control of a universal motor is achieved by varying field flux with tapped field windings, connecting rheostat in series, applying variable voltage by means of silicon controlled rectifier, applying variable voltage by means of variable auto-transformer.
speed
control
universal
motor
thumb_up_alt
0
like
thumb_down_alt
0
dislike
77
views
1
answer
asked
Mar 20, 2018
by
anonymous
Flywheel is used with D.C. compound motor to reduce the peak demand by the motor, compound motor will have to be?
Last answer:
Flywheel is used with D.C. compound motor to reduce the peak demand by the motor, compound motor will have to be cumulatively compounded.
dc
motor
thumb_up_alt
0
like
thumb_down_alt
0
dislike
294
views
1
answer
asked
Mar 20, 2018
by
anonymous
When two D.C. series motors are connected in parallel, the resultant speed is?
Last answer:
When two D.C. series motors are connected in parallel, the resultant speed is normal speed.
dc
series
motors
speed
thumb_up_alt
0
like
thumb_down_alt
0
dislike
306
views
1
answer
asked
Mar 20, 2018
by
anonymous
The speed control of universal motor used for sewing machines is by?
Last answer:
The speed control of universal motor used for sewing machines is by varying the resistance.
speed
control
universal
motor
used
sewing
machines
thumb_up_alt
0
like
thumb_down_alt
0
dislike
70
views
1
answer
asked
Mar 20, 2018
by
anonymous
In case the conditions for maximum power for a D.C. motor are established, the efficiency of the motor will be?
Last answer:
In case the conditions for maximum power for a D.C. motor are established, the efficiency of the motor will be less than 50%.
dc
motor
thumb_up_alt
0
like
thumb_down_alt
0
dislike
97
views
1
answer
asked
Mar 20, 2018
by
anonymous
If a D.C. motor designed for 40°C ambient temperature is to be used for 50°C ambient temperature, then the motor?
Last answer:
If a D.C. motor designed for 40°C ambient temperature is to be used for 50°C ambient temperature, then the motor is to be derated by a factor recommended by manufacturer and select the next higher H.P. motor.
ambient
temperature
motor
dc
thumb_up_alt
0
like
thumb_down_alt
0
dislike
75
views
1
answer
asked
Mar 20, 2018
by
anonymous
The purpose of retardation test on D.C. shunt machines is to find out?
Last answer:
The purpose of retardation test on D.C. shunt machines is to find out stray losses.
dc
shunt
machines
thumb_up_alt
0
like
thumb_down_alt
0
dislike
58
views
1
answer
asked
Mar 20, 2018
by
anonymous
D.C. shunt motors are used for driving?
Last answer:
D.C. shunt motors are used for driving machine tools.
dc
shunt
motors
used
driving
thumb_up_alt
0
like
thumb_down_alt
0
dislike
69
views
1
answer
asked
Mar 20, 2018
by
anonymous
The speed/load characteristics of a universal motor is same as that of?
Last answer:
The speed/load characteristics of a universal motor is same as that of D.C. series motor.
speed
load
characteristics
universal
motor
thumb_up_alt
0
like
thumb_down_alt
0
dislike
69
views
1
answer
asked
Mar 20, 2018
by
anonymous
Which D.C. motor will be suitable along with flywheel for intermittent light and heavy loads?
Last answer:
Cumulatively compounded D.C. motor will be suitable along with flywheel for intermittent light and heavy loads.
dc
motor
thumb_up_alt
0
like
thumb_down_alt
0
dislike
108
views
1
answer
asked
Mar 20, 2018
by
anonymous
The current drawn by the armature of D.C. motor is directly proportional to?
Last answer:
The current drawn by the armature of D.C. motor is directly proportional to the torque required.
dc
motor
thumb_up_alt
0
like
thumb_down_alt
0
dislike
307
views
1
answer
asked
Mar 26, 2018
by
anonymous
A d.c. motor can be looked upon as d.c. generator with the power flow?
A d.c. motor can be looked upon as d.c. generator with the power flow?
Last answer:
A d.c. motor can be looked upon as d.c. generator with the power flow reversed.
dc
motor
thumb_up_alt
0
like
thumb_down_alt
0
dislike
2.8k
views
1
answer
asked
Mar 20, 2018
by
anonymous
Centrifugal switch disconnects the auxiliary winding of the motor at about what percent of synchronous speed?
Last answer:
Centrifugal switch disconnects the auxiliary winding of the motor at about 70 to 80 percent of synchronous speed.
centrifugal
switch
disconnects
auxiliary
winding
motor
synchronous
speed
thumb_up_alt
0
like
thumb_down_alt
0
dislike
141
views
1
answer
asked
Mar 20, 2018
by
anonymous
If the centrifugal switch does not open at 70 to 80 percent of synchronous speed of motor, it would result in?
Last answer:
If the centrifugal switch does not open at 70 to 80 percent of synchronous speed of motor, it would result in damage to the starting winding.
synchronous
speed
motor
thumb_up_alt
0
like
thumb_down_alt
0
dislike
69
views
1
answer
asked
Mar 15, 2018
by
anonymous
Why the speed of synchronous motor is constant?
Why the speed of synchronous motor is constant?
speed
synchronous
motor
constant
thumb_up_alt
0
like
thumb_down_alt
1
dislike
54
views
0
answers
Install Now
...