1 Answer

Usually wide and sensitive speed control is desired in case of colliery winders.

Like 0 like Dislike 0 dislike

Related questions

Description : The speed of a three-phase induction motor is controlled by variable voltage variable frequency control (i.e. keeping V/f constant). As the frequency is reduced, the slip at maximum torque  (1) Decreases (2) Increases (3) Remains constant (4) None of the above

Answer : The speed of a three-phase induction motor is controlled by variable voltage variable frequency control (i.e. keeping V/f constant). As the frequency is reduced, the slip at maximum torque Increases 

Answer : Series motor has the poorest speed control.

Answer : Speed control by Ward Leonard method gives uniform speed variation in both directions.

Answer : Speed control of a universal motor is achieved by varying field flux with tapped field windings, connecting rheostat in series, applying variable voltage by means of silicon controlled rectifier, applying variable voltage by means of variable auto-transformer.

Answer : The speed control of universal motor used for sewing machines is by varying the resistance.

Description : What are the speed control methods of dc motor?

Answer : Field control of DC motor Armature control of DC motor

Description : speed control methods of three phase induction motor?

Answer : Speed control of three phase induction motor

Answer : In Ward-Leonard control the lower limit of speed is imposed by residual magnetism of the generator.

Description : Speed control of the motor using TRIAC

Answer : Speed control of the motor using TRIAC:  This basic phase triggering circuit uses the triac in series with the motor across an AC sinusoidal supply. The variable resistor, VR1 is used ... meaning that it may not trigger at the exact same point for each positive and negative half cycle.

Answer : For constant torque drive armature voltage control speed control method is preferred.

Answer : Most sensitive galvanometer is spot ballistic galvanometer.

Answer : A sensitive galvanometer produces large deflection for a small value of current.

Answer : In case of D.C. shunt motors the speed is dependent on back e.m.f. only because flux is practically constant in D:C. shunt motors.

Answer : In case of a reluctance motor, when the load is increased so that it cannot maintain synchronous speed the motor will run as induction motor.

Answer : The speed of a universal motor is usually reduced by using gearing.

Description : A differentiator is not usually used in control system, because it : - (A) reduces damping  (B) increases error  (C) reduces gain margin  (D) increases input noise

Answer : A differentiator is not usually used in control system, because it : - increases input noise

Answer : The armature voltage control of D.C. motor provides constant torque drive.

Description : Armature control of DC motor

Answer : Armature control of DC motor

Description : Field control of DC motor

Answer : Field control of DC motor

Answer : For the same H.P. rating and full load speed, following motor has poor starting torque differentially compounded.

Description : The fall in speed of a dc generator due to increase in load can be corrected by  (1) cooling the armature.. (2) increasing the excitation. (3) reducing the load voltage. (4) increasing the input to the prime mover

Answer : It   can  be  corrected  by  increasing  the  input  to  the  prime  mover.

Answer : In variable speed motor a weaker commutating field is needed at low speed than at high speed.

Answer : In a D.C. shunt motor, speed is independent of armature current.

Answer : When two D.C. series motors are connected in parallel, the resultant speed is normal speed.

Answer : If the centrifugal switch does not open at 70 to 80 percent of synchronous speed of motor, it would result in damage to the starting winding.

Description : A 240 V, dc shunt motor draws 15 A while supplying the rated load at a speed of 80 rad/s. The armature resistance is 0.5 W and the field winding resistance is 80 W. The net Voltage across armature resistance at the time of plugging will be

Answer : A 240 V, dc shunt motor draws 15 A while supplying the rated load at a speed of 80 rad/s. The armature resistance is 0.5 W and the field winding resistance is 80 W. The net Voltage across armature resistance at the time of plugging will be 474 V

Description : The speed of a 2-pole, 3-phase stepper motor operated by 1200 pulses/min (A) 100 rpm (B) 200 rpm (C) 400 rpm (D) 800 rpm

Answer : The speed of a 2-pole, 3-phase stepper motor operated by 1200 pulses/min 200 rpm

Description : The speed of a D.C. motor can be controlled by varying  1. Its flux per pole 2. Resistance of armature circuit 3. Applied voltage 4. All of the above

Answer : The speed of a D.C. motor can be controlled by varying  1. Its flux per pole 2. Resistance of armature circuit 3. Applied voltage 4. All of the above

Answer : The speed of a D.C. shunt motor can be increased by increasing the resistance in field circuit.

Answer : As the load is increased the speed of D.C. shunt motor will reduce slightly.

Answer : The speed of a D.C. series motor is inversely proportional to the armature current.

Answer : Centrifugal switch disconnects the auxiliary winding of the motor at about 70 to 80 percent of synchronous speed.

Answer : The speed/load characteristics of a universal motor is same as that of D.C. series motor.

Answer : Speed torque characteristic of a repulsion induction motor is similar to that of a D.C. compound motor.

Description : Why the speed of synchronous motor is constant?

Description : State the function of former and control spring in PMMC instrument.

Answer : Function of Former: To support the coil and provide eddy current damping.  Function of Control Spring: To provide control torque or force and in some instruments springs can be used as current leads.

Description : Draw the labeled block diagram of process control system and explain each block.

Answer : Explanation - Process control system consists of process or plant, sensor, error detector, automatic Controller, actuator or control element. 1) Process or plant- process means some manufacturing sequence ... process which changes the process variable. Output of this block is denoted by u .

Description : Draw and explain bulk correction method for power factor & control.

Answer : Bulk correction method for power factor & control: i) Here individual starter controls the capacitors located at distribution panel. ii) Centralized compensation is employed in large industrial plants where many ... capacitor units in steps to maintain P.F. more than preset limit (0.95). 

Description : Write one advantage and one disadvantage each for spring control method and gravity control method.

Answer : Advantages of Spring Control Method: 1) The spring-controlled meters may be used in any position. 2) In some instruments, springs can be used as current leads. 3) As springs are light in weight ... only. 2) Scale is non-uniform. 3) Control weights add to the weight of instrument.

Description : Precise control of reactive current flow entering the transmission and distribution systems can be minimized by using (A) synchronous condenser (B) static VAR capacitor (C) capacitor bank (D) thyristor switched reactor in parallel with capacitor

Answer : Precise control of reactive current flow entering the transmission and distribution systems can be minimized by using (A) synchronous condenser (B) static VAR capacitor (C) capacitor bank (D) thyristor switched reactor in parallel with capacitor

Description : What is control and automation?

Description : What is the difference between a line voltage and low voltage control system?

Description : Explain the principle of ON-OFF control and phase control of AC voltage controller with suitable circuit and waveforms.

Answer : The integral cycle control (on-off control) and phase angle control are the two types of AC voltage controller. The principle of ON-OFF control: The on-off control is also called an integral cycle ... control. In phase control, the switch is on for some period of each cycle.  

Description : What is HT and LT control panels?

Answer : HT Panel is like LT Panel except that it is used for high tension cables. LT Panels :LT Panel is an electrical distribution board that receives power from generator or transformer and distributes the same to various electronic devices and distribution boards. 

Description : Write function of control rods in nuclear power plant.

Answer : Function of control rods in nuclear power plant: The function of control rod is to control the chain reaction in reactor core by adjusting its height.

Description : Describe spring control method of producing controlling torque in measuring instrument. Write any two properties required for spring material.

Answer : A)Spring control method: As shown in the figure, the inner ends of the both springs are attahced to the spindle, while outer end of upper spring is attached to the lever and outer ... of spring material: 1.Non Magnetic material 2.Low specific resistance 3.Low temperature coefficient of resistance

Description : The meter which does not have any component in it to provide control torque is (A) Electrodynamometer for current measurement (B) Electrodynamometer for voltage measurement (C) Electrodynamometer for power measurement. (D) Electrodynamometer for power factor measurement.

Answer : The meter which does not have any component in it to provide control torque is Electrodynamometer for power factor measurement.

Description : Regulating-transformers are used in power systems for control of

Answer : Regulating-transformers are used in power systems for control of power flow

Description : Negative feedback in a closed-loop control system DOES NOT (A) reduce the overall gain (B) reduce bandwidth (C) improve disturbance rejection (D) reduce sensitivity to parameter variation

Answer : Negative feedback in a closed-loop control system DOES NOT reduce bandwidth

Description : The standard for long distance analog signal transmission in process control industry is (A) 4-20 mV (B) 0-20 mA (C) 4-20 mA (D) 0-5 V

Answer : The standard for long distance analog signal transmission in process control industry is 4-20 mA