Answer :
A.C. series motor as compared to D.C. series motor has smaller brush width, less number of field turns, more number of armature turns, less air gap.
asked
Mar 20, 2018
by
anonymous
Answer :
If a D.C. motor is connected across the A.C. supply it will burn due to heat produced in the field winding by eddy currents.
asked
Mar 20, 2018
by
anonymous
Answer :
In a D.C. series motor, if the armature current is reduced by 50%, the torque of the motor will be equal to 25% of the previous value.
asked
Mar 20, 2018
by
anonymous
Description : State the modification to be done in dc series motor to work satisfactorily as ac series motor. State applications of ac series motor.
Answer :
Modifications are necessary in a dc series motor so that it operates satisfactorily on ac supply. The modifications are as follows: 1) AC series motor is built with a few field turns as ... and grinders 5) High speed vacuum cleaners 6) Sewing machines 7) Food processors 8) Drilling machine
asked
May 7, 2020
by
anonymous
Answer :
When a D.C. series motor is connected to A.C. supply, the power factor will be low because of high inductance of field and armature circuits.
asked
Mar 20, 2018
by
anonymous
Answer :
In a A.C. series motor armature coils are usually connected to commutator through resistance.
asked
Mar 20, 2018
by
anonymous
Description : We connected a 35V dc supply to a resistance of 600 Ohm in series with an unknown resistance R.A. voltmeter having a resistance of 1.2 kOhm is connected across 600 Ohm resistance and read 5v. The value of resistance R will be
Answer :
We connected a 35V dc supply to a resistance of 600 Ohm in series with an unknown resistance R.A. voltmeter having a resistance of 1.2 kOhm is connected across 600 Ohm resistance and read 5v. The value of resistance R will be 2.4 kOhm
asked
May 8, 2018
by
anonymous
Answer :
The speed of a D.C. series motor is inversely proportional to the armature current.
asked
Mar 20, 2018
by
anonymous
Answer :
A D.C. series motor is that which has its field winding consisting of thick wire and less turns.
asked
Mar 20, 2018
by
anonymous
Answer :
The direction of rotation of a D.C. series motor can be changed by interchanging field terminals.
asked
Mar 20, 2018
by
anonymous
Description : In a 2 kW, 200 V, 1000 rpm. DC series motor the torque at full load was found to be 0.3 N -m. The torque at half full load in N -m is :
Answer :
In a 2 kW, 200 V, 1000 rpm. DC series motor the torque at full load was found to be 0.3 N -m. The torque at half full load in N -m is : 0.075
asked
Apr 29, 2018
by
anonymous
Description : Describe the reason of using dc series motor for electric trains.
Answer :
Electric trains require an inverse torque speed characteristics for proper operation. That is a higher torque is required at start (when speed is nil or low) and as the train picks up ... torque - speed characteristics of DC series motors match, these motors are suitable for electric trains
asked
Sep 18, 2018
by
anonymous
Description : The speed of a 2-pole, 3-phase stepper motor operated by 1200 pulses/min (A) 100 rpm (B) 200 rpm (C) 400 rpm (D) 800 rpm
Answer :
The speed of a 2-pole, 3-phase stepper motor operated by 1200 pulses/min 200 rpm
asked
Apr 28, 2018
by
anonymous
Answer :
In A.C. series motor compensating winding is employed to reduce sparking at the brushes.
asked
Mar 20, 2018
by
anonymous
Answer :
Reason is kinetic energy
asked
Mar 20, 2018
by
anonymous
Description : Brake test on DC series motor
Answer :
.embed-container { position: relative; padding-bottom: 56.25%; height: 0; overflow: hidden; max-width: 100%; } .embed-container iframe, .embed-container object, .embed-container embed { position: absolute; top: 0; left: 0; width: 100%; height: 100%; }
asked
Apr 21, 2020
by
anonymous
Description : A change of 4% in the supply voltage to an induction motor will produce a change of approximately
Answer :
A change of 4% in the supply voltage to an induction motor will produce a change of approximately 8% in the rotor torque
asked
May 8, 2018
by
anonymous
Description : Why a dc series motor has a high starting torque?
asked
Mar 15, 2018
by
anonymous
Answer :
At the instant of starting when a D.C. motor is put on supply, it behaves like a low resistance circuit.
asked
Mar 20, 2018
by
anonymous
Description : What are the advantages of DC series motor?
asked
Mar 15, 2018
by
anonymous
Description : Why dc series motor should not be started at no load?
asked
Mar 15, 2018
by
anonymous
Answer :
Induction motor is a AC motor it is also known as asynchronous motor .
asked
Sep 9, 2017
by
anonymous
Description : What will happen if the primary of a transformer is connected to D.C. supply? (A) Transformer will operate with low efficiency (B) Transformer will operate with high efficiency (C) No effect (D) Transformer may start to smoke and burn
Answer :
What will happen if the primary of a transformer is connected to D.C. supply? (A) Transformer will operate with low efficiency (B) Transformer will operate with high efficiency (C) No effect (D) Transformer may start to smoke and burn
asked
May 8, 2018
by
anonymous
Description : Two 100W, 200V lamps are connected in series across a 200V supply. The total power consumed by each lamp will be in Watts
Answer :
4800
asked
May 8, 2018
by
anonymous
Answer :
If the synchronous motor, properly synchronised to the supply is running on no load and is having negligible loss then the stator current will be zero.
asked
Mar 20, 2018
by
anonymous
Answer :
The armature may burn if the back e.m.f. of a D.C. motor vanishes suddenly.
asked
Mar 20, 2018
by
anonymous
Description : A capacitor-start single phase induction motor is switched on to supply with its capacitor replaced by an inductor of equivalent reactance value. It will?
Answer :
A capacitor-start single phase induction motor is switched on to supply with its capacitor replaced by an inductor of equivalent reactance value. It will not start at all.
asked
Mar 20, 2018
by
anonymous
Answer :
In case of conductively compensated D.C. series motors, the compensating winding is provided in series with armature winding.
asked
Mar 20, 2018
by
anonymous
Answer :
When two D.C. series motors are connected in parallel, the resultant speed is normal speed.
asked
Mar 20, 2018
by
anonymous
Answer :
In case the back e.m.f. and the speed of a D.C. motor are doubled, the torque developed by the motor will remain unchanged.
asked
Mar 20, 2018
by
anonymous
Answer :
In case the conditions for maximum power for a D.C. motor are established, the efficiency of the motor will be less than 50%.
asked
Mar 20, 2018
by
anonymous
Answer :
In a D.C. shunt motor, under the conditions of maximum power, the current in the armature will be more than full-load current.
asked
Mar 20, 2018
by
anonymous
Answer :
As the load is increased the speed of D.C. shunt motor will reduce slightly.
asked
Mar 20, 2018
by
anonymous
Answer :
Flywheel is used with D.C. compound motor to reduce the peak demand by the motor, compound motor will have to be cumulatively compounded.
asked
Mar 20, 2018
by
anonymous
Answer :
Cumulatively compounded D.C. motor will be suitable along with flywheel for intermittent light and heavy loads.
asked
Mar 20, 2018
by
anonymous
Description : Write two applications of D.C. series motor.
Answer :
The applications of D.C. series motor: 1. Cranes 2. Hoists 3. Trolley and cars 4. Conveyors 5. For traction work i.e. electric locomotives 6. Elevator 7. Air compressor
asked
Apr 27, 2020
by
anonymous
Answer :
By looking at Commutator part of the motor, it can be easily confirmed that a particular motor is D.C. motor.
asked
Mar 20, 2018
by
anonymous
Answer :
If a D.C. motor designed for 40°C ambient temperature is to be used for 50°C ambient temperature, then the motor is to be derated by a factor recommended by manufacturer and select the next higher H.P. motor.
asked
Mar 20, 2018
by
anonymous
Answer :
For a D.C. shunt motor if the excitation is changed torque will change but power will remain constant.
asked
Mar 20, 2018
by
anonymous
Answer :
In a differentially compounded D.C. motor, if shunt field suddenly opens the motor will first stop and then run in opposite direction as series motor.
asked
Mar 20, 2018
by
anonymous
Answer :
If a D.C. shunt motor is working at no load and if shunt field circuit suddenly opens this will result in excessive speed, possibly destroying armature due to excessive centrifugal stresses.
asked
Mar 20, 2018
by
anonymous
Answer :
If the field of a D.C. shunt motor gets opened while motor is running the motor will attain dangerously high speed.
asked
Mar 20, 2018
by
anonymous
Description : If a transformer is continuously operated the maximum temperature rise will occur in?
Answer :
If a transformer is continuously operated the maximum temperature rise will occur in windings.
asked
Mar 19, 2018
by
anonymous
Description : An AC supply of 230 V is applied to a half-wave rectifier circuit through a transformer having primary to secondary turn’s ratio 12:1. The peak inverse voltage is A) 8.62 V B) 12 V C) 19.17 V D) 27.11 V
Answer :
An AC supply of 230 V is applied to a half-wave rectifier circuit through a transformer having primary to secondary turn’s ratio 12:1. The peak inverse voltage is A) 8.62 V B) 12 V C) 19.17 V D) 27.11 V
asked
Jun 18, 2018
by
anonymous
Description : Total instantaneous power supplied by a 3-phase ac supply to a balanced R-L load is
Answer :
Total instantaneous power supplied by a 3-phase ac supply to a balanced R-L load is constant
asked
Apr 28, 2018
by
anonymous
Description : Why does a transformer only work with an AC supply?
Answer :
The transformer work depends on the induction as main principle ,for that AC is the right means
asked
Mar 14, 2018
by
anonymous
Description : Draw the waveform of three phase AC supply voltage.
asked
Aug 11, 2018
by
anonymous
Description : The SCR would be turned OFF by voltage reversal of applied anode-cathode ac supply frequency of A) 10 kHz B) 10 Hz C) 5 kHz D) 5 Hz
asked
Jun 18, 2018
by
anonymous
Answer :
If the speed of a D.C. shunt motor is increased, the back e.m.f. of the motor will increase.
asked
Mar 20, 2018
by
anonymous
Description : To measure an A. C. voltage by using an A.C. potentiometer, it is desirable that the supply for the potentiometer in taken?
Answer :
To measure an A. C. voltage by using an A.C. potentiometer, it is desirable that the supply for the potentiometer in taken from the same source as the unknown voltage.
asked
Mar 21, 2018
by
anonymous