To reverse the direction of rotation of a capacitor start motor while it is running we should disconnect motor from the supply till it stops then reconnect it to supply with reversed connection of main or auxiliary winding.

thumb_up_alt 0 like thumb_down_alt 0 dislike

Related questions

Answer : In a capacitor start motor, the phase displacement between starting and running winding can be nearly 90°.

Description : Explain the working of a single phase capacitor start induction motor. 

Answer : Single phase capacitor start induction motor https://youtu.be/31lvvzU5Puc

Answer : In a capacitor start single-phase motor, when capacitor is replaced by a resistance motor will continue to run in same direction.

Description : How can we reverse the direction of rotation of synchronous motor?

Answer : By reversing supply phase sequence we can reverse the direction of rotation of synchronous motor.

Description : how can we reverse the direction of rotation of three phase induction motor ?

Answer : The direction of rotation of three phase induction motor can be reversed by plugging i.e by changing any two out of three phases of the supply to the stator of the Induction motor terminal.

Answer : In a capacitor start and run motors the function of the running capacitor in series with the auxiliary winding is to improve power factor.

Answer : The direction of rotation of a D.C. series motor can be changed by interchanging field terminals.

Answer : The direction of rotation of universal motor can be reversed the by reversing the flow of current through either armature winding or field winding.

Answer : In capacitor start single-phase motors current in the starting winding leads the voltage.

Description : The direction of rotation of an inverter fed 3-phase ac motor is reversed by (A) a mechanical reversing switch (B) reversing the input dc link voltage (C) operating the inverter as a rectifier (D) changing the sequence of switching

Answer : The direction of rotation of an inverter fed 3-phase ac motor is reversed by changing the sequence of switching

Answer : In case of a shaded pole motor the direction of rotation of the motor is from main pole to shaded pole.

Answer : Direction of rotation of a split phase motor can be reversed by reversing the connection of either running winding or starting winding.

Answer : The direction of rotation of an hysteresis motor is determined by position of shaded pole with respect to main pole.

Answer : In repulsion motor direction of rotation of motor is the same as that of brush shift.

Description : Why synchronous motor Cannot start itself?

Description : A capacitor-start single phase induction motor is switched on to supply with its capacitor replaced by an inductor of equivalent reactance value. It will?

Answer : A capacitor-start single phase induction motor is switched on to supply with its capacitor replaced by an inductor of equivalent reactance value. It will not start at all.

Description : I got some grapic drawing questions guys and I need to see the answers immediately.Stator voltage curve for each four different start up methods.

Answer : In a two value capacitor motor, the capacitor used for running purposes is paper spaced oil filled type.

Description : Which type of starter is used to start the DC motor?

Answer : The repulsion-start induction-run motor is used because of high starting torque.

Answer : If the centrifugal switch of a two-value capacitor motor using two capacitors fails to open then Electrolytic capacitor will, in all probability, suffer break down.

Description : Can we use the synchronous motor as the synchronous capacitor?

Answer : Yes, we can use the synchronous motor as the synchronous capacitor when the synchrnous motor is overexcited.

Answer : Two-value capacitor motor finds increased application as compressor motor in small home air-conditioners because it has low starting as well as running currents at relatively high power factor.

Answer : In a ceiling fan employing capacitor run motor secondary winding surrounds the primary winding.

Description : In a synchronous machine, if the field flux axis ahead of the armature field axis in the direction of rotation, the machine is operating as  (1) synchronous motor (2) synchronous generator (3) asynchronous motor (4) asynchronous generator

Answer : In a synchronous machine, if the field flux axis ahead of the armature field axis in the direction of rotation, the machine is operating as synchronous generator 

Description : Why is a capacitor used in a single phase motor and not in three phase motor ?

Answer : In 1-phase induction motor capacitor work is generate the auxiliary winding current than excite the main winding to rotor starts rotate. After rotor start rotating about 75% of their speed than auxiliary ... emf to start the motor.so,in 3-phase induction motor is self start induction motor.

Answer : The value of starting capacitor of a fractional horse power motor will be 300 uF .

Answer : If the capacitor of a single-phase motor is short-circuited the motor will not start.

Description : What is the difference between a soft start and a VFD?

Description : What is a soft start?

Answer : If the field of a D.C. shunt motor gets opened while motor is running the motor will attain dangerously high speed.

Description : What is the direction of flow when charging a capacitor?

Answer : Capacitor use in fan is made up of dielectic material which is in semi solid material having high capacity.but generation of heat in capacitor the semi solid material converted into dry solid because of ... capacity becomes lower and lower so for good result of our fan we have to change it.

Description : A three-phase synchronous motor connected to ac mains is running at full load and unity power factor. lf its shaft load is reduced by half and field current is held constant then its new power factor will be

Answer : Leading

Description : A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is

Answer : A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is 36 Ohm

Description : The effect of increasing load on a synchronous motor running with normal excitation is (A) Increase both its Ia and power factor. (B) Decrease Ia, but increase power factor. (C) Increase Ia, but decrease power factor (D) Decrease both Ia and power factor.

Answer : The effect of increasing load on a synchronous motor running with normal excitation is Increase Ia, but decrease power factor

Description : An 8-pole, 50Hz, three-phase induction motor is running at 705rpm and has a rotor copper loss of 5kW. Its rotor input is (A) 5.06 kW (B) 0.3 kW (C) 100 kW (D) 83.33 kW

Answer : An 8-pole, 50Hz, three-phase induction motor is running at 705rpm and has a rotor copper loss of 5kW. Its rotor input is 83.33 kW

Answer : The capacitors used in single-phase capacitor motors have no polarity marking.

Answer : In a split phase motor, the running winding should have low resistance and high inductance.

Description : To reverse the direction of rotation of a three-phase AC induction motor, do one of the following: w) reverse any two of the three-phase connections x) change the frequency of the applied AC power y) operate the motor below the stall torque at very high slip z) none of the above

Answer : ANSWER: W -- REVERSE ANY TWO OF THE THREE-PHASE CONNECTIONS 

Description : A 240 V, dc shunt motor draws 15 A while supplying the rated load at a speed of 80 rad/s. The armature resistance is 0.5 W and the field winding resistance is 80 W. The net Voltage across armature resistance at the time of plugging will be

Answer : A 240 V, dc shunt motor draws 15 A while supplying the rated load at a speed of 80 rad/s. The armature resistance is 0.5 W and the field winding resistance is 80 W. The net Voltage across armature resistance at the time of plugging will be 474 V

Description : How can we improve power factor using synchronous motor?

Answer : Yes, we can make the power factor of synchronous motor leading by adjusting its excitation.

Description : Power factor of an inductive circuit is usually improved by connecting capacitor to it in?

Answer : Power factor of an inductive circuit is usually improved by connecting capacitor to it in parallel.

Description :  As compared to a split phase motor, a capacitor start motor has _____.

Answer :  As compared to a split phase motor, a capacitor start motor has higher starting torque.

Answer : The rotor slots, in an induction motor, are usually not quite parallel to the shaft because it helps in reducing the tendency of the rotor teeth to remain under the stator teeth.

Answer : If the centrifugal switch does not open at 70 to 80 percent of synchronous speed of motor, it would result in damage to the starting winding.

Description : If we change the excitation of synchronous machine will it affect on motor speed?

Answer : No, If we change the excitation of synchronous machine it will not affect on motor speed.

Description : We always see the same face of the moon, because (1) it is smaller than the earth (2) it revolves on its axis in a direction opposite to that of the earth (3) it takes equal time for revolution around the earth and rotation on its own axis (4) it rotates at the same speed as the earth around the sun

Answer : it takes equal time for revolution around the earth and rotation on its own axis