Answer :

If the centrifugal switch of a two-value capacitor motor using two capacitors fails to open then Electrolytic capacitor will, in all probability, suffer break down.

Like 0 like
Next Page →

Related

Answer : Centrifugal switch disconnects the auxiliary winding of the motor at about 70 to 80 percent of synchronous speed.

Answer : In a single phase motor the centrifugal switch disconnects auxiliary winding of the motor.

Answer : A centrifugal switch is used to disconnect starting winding when motor has picked up about 50 to 70 per cent of rated speed.

Answer : Two-value capacitor motor finds increased application as compressor motor in small home air-conditioners because it has low starting as well as running currents at relatively high power factor.

Answer : If the centrifugal switch does not open at 70 to 80 percent of synchronous speed of motor, it would result in damage to the starting winding.