search
person

1 Answer

If the centrifugal switch of a two-value capacitor motor using two capacitors fails to open then Electrolytic capacitor will, in all probability, suffer break down.

thumb_up_alt 0 like thumb_down_alt 0 dislike

Related questions

Answer : Centrifugal switch disconnects the auxiliary winding of the motor at about 70 to 80 percent of synchronous speed.

Answer : A centrifugal switch is used to disconnect starting winding when motor has picked up about 50 to 70 per cent of rated speed.

Answer : In a single phase motor the centrifugal switch disconnects auxiliary winding of the motor.

Answer : Two-value capacitor motor finds increased application as compressor motor in small home air-conditioners because it has low starting as well as running currents at relatively high power factor.

Answer : If the centrifugal switch does not open at 70 to 80 percent of synchronous speed of motor, it would result in damage to the starting winding.

Answer : In a two value capacitor motor, the capacitor used for running purposes is paper spaced oil filled type.

Answer : To reverse the direction of rotation of a capacitor start motor while it is running we should disconnect motor from the supply till it stops then reconnect it to supply with reversed connection of main or auxiliary winding.

Answer : In a ceiling fan employing capacitor run motor secondary winding surrounds the primary winding.

Answer : The value of starting capacitor of a fractional horse power motor will be 300 uF .

Answer : If the capacitor of a single-phase motor is short-circuited the motor will not start.

Description : A capacitor-start single phase induction motor is switched on to supply with its capacitor replaced by an inductor of equivalent reactance value. It will?

Answer : A capacitor-start single phase induction motor is switched on to supply with its capacitor replaced by an inductor of equivalent reactance value. It will not start at all.

Description : Why is a capacitor used in a single phase motor and not in three phase motor ?

Answer : In 1-phase induction motor capacitor work is generate the auxiliary winding current than excite the main winding to rotor starts rotate. After rotor start rotating about 75% of their speed than auxiliary ... emf to start the motor.so,in 3-phase induction motor is self start induction motor.

Description : Explain the working of a single phase capacitor start induction motor. 

Answer : Single phase capacitor start induction motor https://youtu.be/31lvvzU5Puc

Answer : In a capacitor start single-phase motor, when capacitor is replaced by a resistance motor will continue to run in same direction.

Answer : In a capacitor start motor, the phase displacement between starting and running winding can be nearly 90°.

Description : Can we use the synchronous motor as the synchronous capacitor?

Answer : Yes, we can use the synchronous motor as the synchronous capacitor when the synchrnous motor is overexcited.

Answer : The capacitors used in single-phase capacitor motors have no polarity marking.

Description : State two advantages and disadvantages of centrifugal casting. Write four applications.

Answer : Centrifugal Casting: Advantages: 1. Relatively very light impurities move inwards towards center. So they can be removed easily thus helping in producing sound castings. 2. Gates and risers are not needed. ... making rollers. 4. Piston rings. 5. Cylinder liners. 6. Pipes of water gas sewage.

Description : What is the charge on each capacitor when a 150 V is applied across two capacitors with values 5 μF and 10 μF, connected in series? A) 500 μC B) 0.5 μC C) 0.5 C D) None of these

Answer : What is the charge on each capacitor when a 150 V is applied across two capacitors with values 5 μF and 10 μF, connected in series? A) 500 μC B) 0.5 μC C) 0.5 C D) None of these

Description : In an induction motor if the flux density is reduced to one-half, of its normal value then the torque will  (1) reduce to one-half (2) reduce to one-fourth (3) remain unchanged (4) increase four times

Answer : In an induction motor if the flux density is reduced.to one-half, of its normal value then the torque will reduce to one-fourth

Description : Draw & explain touch plate switch using IC555.

Answer : It is construct form monostable multivibrator , when metal plates touch by finger then voltage at pin number 2 goes to below 1/3 Vcc then output of lower comparator becomes high hence flip flop set and ... then output of timer goes low and it low till up to the metal plates touch by finger .

Description : A switch tail ring counter is made by using a single D-FF. The resulting circuit is (A) T-FF (B) D-FF (C) SR-FF (D) JK-FF

Answer : A switch tail ring counter is made by using a single D-FF. The resulting circuit is T-FF

Description : A 3 micro Faraday capacitor is connected closing a switch to a supply of 100 V through 1 milli ohm series resistance. Calculate 1 the time constant 2 initial charging current 3 the initial rate of ... second,after the switch has been closed 5 the time taken for the capacitor to be fully charged.

Answer : If a D.C. motor designed for 40°C ambient temperature is to be used for 50°C ambient temperature, then the motor is to be derated by a factor recommended by manufacturer and select the next higher H.P. motor.

Description : Give the function of fuse and switch.

Answer : Functions of fuse:  * To break the circuit under fault condition.  * To provide overcurrent protection to the circuit.  * To provide short circuit protection to the circuit.  * To provide ...  * To make the electric circuit manually.  * To break the electric circuit manually.

Description : State the function of : i) MCCB ii) ELCB iii) MCB iv) Switch. 

Answer : i) MCB: Provide short circuit protection & over load protection to electrical loads.  ii) ELCB: Provides protection by detecting the unsafe magnitudes leakage currents flowing to earth and disconnecting ... rating.  iv) Switch: Make and break the electrical connection to the load manually.

Description : Transfer switch

Answer : .embed-container { position: relative; padding-bottom: 56.25%; height: 0; overflow: hidden; max-width: 100%; } .embed-container iframe, .embed-container object, .embed-container embed { position: absolute; top: 0; left: 0; width: 100%; height: 100%; }

Description : How rating of main switch and cable is selected for Industrial Installation.

Answer : 1. Rating of Main Switch or Fuse Rating is decided in industrial installation: Rating of main switch or fuse is based up the starting current of motor. For calculating starting current is considered 2 ... take 1.5 times the rated current or full load current. & thus cable rating is decided.

Description : Earthing switch is used for?  (A) Measuring of safety voltage (B) Protection of equipment from ground faults (C) Discharging residual energies (D) All of the above 

Answer : Earthing switch is used for?  (A) Measuring of safety voltage (B) Protection of equipment from ground faults (C) Discharging residual energies (D) All of the above 

Description : The device which allows reverse power flow and withstands highest switch frequency is (A) GTO (B) MOSFET (C) IGBT (D) Inverter grade SCR

Answer : The device which allows reverse power flow and withstands highest switch frequency is MOSFET

Description : A closed switch has a resistance of?

Answer : A closed switch has a resistance of zero.

Answer : The switch board instruments should be mounted in vertical position.

Answer : A thermal protection switch can protect against overload.

Answer : Yes ,it is one of the main advantage using thristors as a  switch in DC  circuit ,it has a high current gain

Answer : Yes, SCR is a unidirectional switch.

Description : What are the desirable characteristics of ideal switch?

Answer : Desirable characteristics of the ideal switch: It is desirable to have power switches characteristics closer to ideal switch. The ideal switch should have the following characteristics. Zero resistance when ... . 100% efficiency. Able to control power flow with zero power dissipation.

Description : What is the difference between a switch and a relay?

Answer : Switch is simply a mechanical contact mechanism and relay is a electromagnetic switch . Switch can be direct mechanically turn on and off but relay can be operated by energising coil .

Answer : BJT act as switch in saturation and  cutoff region ( ON state in saturation region and OFF state in cut-off region )

Answer : Because it has a higher switching frequency and heat tolerance.

Description : In a single-phase induction motor when the rotor is stationary and voltage is applied to the stator, then (A) the flux is constant (B) the flux first decreases and then increases in ... increases and decreases in the opposite direction with the same magnitude (D) current flows through the rotor

Answer : In a single-phase induction motor when the rotor is stationary and voltage is applied to the stator, then the flux first decreases and then increases in the same direction

Description : What happens to the capacitance if mica is inserted between the plates of an air capacitor? A) The capacitance increases B) The capacitance decreases C) The capacitance remains the same D) The capacitance becomes zero

Answer : What happens to the capacitance if mica is inserted between the plates of an air capacitor? A) The capacitance increases B) The capacitance decreases C) The capacitance remains the same D) The capacitance becomes zero

Description : Describe the reason of using dc series motor for electric trains.

Answer : Electric trains require an inverse torque speed characteristics for proper operation. That is a higher torque is required at start (when speed is nil or low) and as the train picks up ... torque - speed characteristics of DC series motors match, these motors are suitable for electric trains

Description : For using regenerative breaking, the most suitable motor is :  (A) DC series motor  (B) Slip ring induction motor  (C) Squirrel cage induction motor  (D) Synchronous motor

Answer : For using regenerative breaking, the most suitable motor is : Slip ring induction motor

Answer : The speed of a universal motor is usually reduced by using gearing.

Description : How can we improve power factor using synchronous motor?

Answer : If the current in a capacitor leads the voltage by 80°, the loss angle of the capacitor is 10°.

Description : Do capacitors in parallel have the same voltage?

Answer : Not same but we will get addition of both values when capacitors are connected in parallel...

Answer : If the field winding of an unloaded salient pole synchronous motor is open circuited, the motor will stop.

Description : Torque developed by a three-phase, 400V, induction motor is 100 N -m. If the applied voltage is reduced to 200-V, the d'veloped torque will be

Answer : Torque developed by a three-phase, 400V, induction motor is 100 N -m. If the applied voltage is reduced to 200-V, the d'veloped torque will be 25 N -m

Answer : In a D.C. series motor, if the armature current is reduced by 50%, the torque of the motor will be equal to 25% of the previous value.

← Prev Question Next Question →
editChoose topic
...