In split-phase motor auxiliary winding is of thin wire placed at the top of the slots.

Like 0 like
Next Page →

Related

Answer : Centrifugal switch disconnects the auxiliary winding of the motor at about 70 to 80 percent of synchronous speed.

Answer : In a capacitor start and run motors the function of the running capacitor in series with the auxiliary winding is to improve power factor.

Answer : In a split phase motor, the running winding should have low resistance and high inductance.

Description : In a split-phase induction motor, the resistance/reactance ratios of windings are such that (A) current in the auxiliary winding leads the current in the main winding (B) current in the ... (C) both windings develop the same starting torque (D) both windings develop high starting current

Answer : In a split-phase induction motor, the resistance/reactance ratios of windings are such that current in the auxiliary winding leads the current in the main winding

Answer : In split phase motor main winding is of thick wire placed at the bottom of the slots.