1 Answer

The power factor of a single-phase induction motor is usually lagging.

Like 0 like Dislike 0 dislike

Related questions

Answer : A single-phase induction motor is inherently non-self-starting with low torque.

Description : A synchronous motor has better power factor as compared to that of an equivalent induction motor. This is mainly because?

Answer : A synchronous motor has better power factor as compared to that of an equivalent induction motor. This is mainly because stator supply is not required to produce magnetic field.

Answer : An induction motor has relatively high power factor at near full load.

Description : At which time power factor of the induction motor is low?

Answer : The power factor of the inducction motor is low at the time of starting as compare to while the induction motor is running.

Description : In a single-phase induction motor, the operating direction is determined by the ________ A) Rotor B) Stator C) Starting circuit D) None of these

Answer : In a single-phase induction motor, the operating direction is determined by the Starting circuit

Description : In a single-phase induction motor when the rotor is stationary and voltage is applied to the stator, then (A) the flux is constant (B) the flux first decreases and then increases in ... increases and decreases in the opposite direction with the same magnitude (D) current flows through the rotor

Answer : In a single-phase induction motor when the rotor is stationary and voltage is applied to the stator, then the flux first decreases and then increases in the same direction

Answer : If starting winding of a single-phase induction motor is left in the circuit, it will draw excessive current and overheat.

Description : Power factor of an inductive circuit is usually improved by connecting capacitor to it in?

Answer : Power factor of an inductive circuit is usually improved by connecting capacitor to it in parallel.

Answer : Single phase induction motor usually operates on 0.6 power factor lagging.

Answer : When a D.C. series motor is connected to A.C. supply, the power factor will be low because of high inductance of field and armature circuits.

Description : A capacitor-start single phase induction motor is switched on to supply with its capacitor replaced by an inductor of equivalent reactance value. It will?

Answer : A capacitor-start single phase induction motor is switched on to supply with its capacitor replaced by an inductor of equivalent reactance value. It will not start at all.

Answer : In a shaded pole motor, the shading coil usually consist of a single turn of heavy copper wire which is short-circuited and carries only induced current.

Answer : In a capacitor start single-phase motor, when capacitor is replaced by a resistance motor will continue to run in same direction.

Answer : In a shaded pole single-phase motor, the revolving field is produced by the use of shading coils.

Answer : The rotor developed by a single-phase motor at starting is zero.

Answer : If the capacitor of a single-phase motor is short-circuited the motor will not start.

Description : Explain energy conservation technique “by improving power quality” for induction motor.

Answer : Energy conservation method in induction motor by improving power quality: Electrical energy can be conserved by improving the power quality. It can be achieved by avoiding voltage unbalance, maintaining ... losses can be minimized by using harmonic filter thus reducing the harmonics in the system.

Description : If the load of the normally excited synchronous motor is increased the power factor will?

Answer : If the load of the normally excited synchronous motor is increased the power factor will become lagging.

Description : The synchronous motor which works on leading power factor and does not drive any mechanical load is called?

Answer : The synchronous motor which works on leading power factor and does not drive any mechanical load is called synchronous condenser.

Description : If the field of synchronous motor is under excited, power factor will be?

Answer : If the field of synchronous motor is under excited, power factor will be lagging.

Description : How can we improve power factor using synchronous motor?

Answer : Yes, we can make the power factor of synchronous motor leading by adjusting its excitation.

Description : The number of poles in a phase induction motor at 50 Hz and running at 1500 rpm will be?

Answer : The number of poles in a phase induction motor at 50 Hz and running at 1500 rpm will be 4.

Description : Explain the working of a single phase capacitor start induction motor. 

Answer : Single phase capacitor start induction motor https://youtu.be/31lvvzU5Puc

Description : What is the slip (as a percentage) when a 6 pole single phase induction motor operating on 220 V and 60 Hz is rotating at speed of 1140 rpm? A) 60% B) 5% C) 10% D) None of these

Answer : What is the slip (as a percentage) when a 6 pole single phase induction motor operating on 220 V and 60 Hz is rotating at speed of 1140 rpm? A) 60% B) 5% C) 10% D) None of these

Answer : If a single phase induction motor runs slower than normal, the most likely defect is worn bearings.

Description : How does a single phase induction motor work?

Answer : As we know that single phase induction is not self started because for self started we require atleast two revolving field but single phase induction motor has only one. So we provide extra ... 1phase IM classified as split phase IM, capacitor start capacitor run, capacitor start induction run.

Description : explain the working of single phase induction motor.

Answer : Stator has two winding namely main winding and auxiliary winding.when single phase ac supply is given to the motor,its produces alternating field.this field cut by a cage rotor.so some emf ... due to this emf,rotor flux produced.the interaction between two fluxes produce torque.so rotor rotates.

Answer : Capacitor start motor has high torque in starting

Description : Single Phase Induction Motor

Answer : Single Phase Induction Motor Single phase induction motor is mostly used in home, office, shop and many single phase appliances like pumps,  ... torque and silent operation. It is uses where silent operation is required.

Answer : In a A.C. series motor armature coils are usually connected to commutator through resistance.

Answer : The efficiency of a properly designed synchronous motor will usually fall in range 85 to 95%.

Description : The no-load speed of a single-phase SCR bridge converter fed separately excited dc motor operating at a firing delay angle, α and flux, Φ (A) directly proportional to α and Φ (B) ... proportional to α and inversely proportional to Φ (D) directly proportional to Φ and inversely proportional to α

Answer : The no-load speed of a single-phase SCR bridge converter fed separately excited dc motor operating at a firing delay angle, α and flux, Φ directly proportional to α and inversely proportional to Φ

Answer : The starting winding of a single-phase motor is placed in stator.

Description : What is the power factor when a single phase watt meter operating on 200 V and 5 A for 5 hours makes 2016 revolutions and the meter constant in revolution is 420? A) 0.04 B) 1.04 C) 0.96 D) None of these

Answer : What is the power factor when a single phase watt meter operating on 200 V and 5 A for 5 hours makes 2016 revolutions and the meter constant in revolution is 420? A) 0.04 B) 1.04 C) 0.96 D) None of these

Answer : The power factor of a single phase load can be calculated if the instruments available are three ammeters or three voltmeters.

Answer : In a single phase power factor meter the phase difference between the currents in the two pressure coils is exactly 90°.

Answer : The two pressure coils of a single phase power factor meter have the same dimensions and the same number of turns.

Answer : The repulsion-start induction-run motor is used because of high starting torque.

Answer : The rotor slots, in an induction motor, are usually not quite parallel to the shaft because it helps in reducing the tendency of the rotor teeth to remain under the stator teeth.

Description : Explain with neat circuit diagrams the procedures to perform no load and blocked rotor tests on three phase induction motor.

Description : Explain the need and steps to conduct the reduced voltage running up test on the three phase induction motor.

Description : State any four advantages of three phase induction motor. 

Answer : Advantages of three phase induction motor https://youtu.be/27OIOCKN05U

Description : Split phase induction motor

Answer : Split phase induction motor : There are two windings used in split phase induction motor. It is a type of single-phase induction motor. There are two winding one is called main winding and ... motor have low starting torque it is used for small fans, blowers, centrifugal pumps, grinders etc.

Description : The speed of a three-phase induction motor is controlled by variable voltage variable frequency control (i.e. keeping V/f constant). As the frequency is reduced, the slip at maximum torque  (1) Decreases (2) Increases (3) Remains constant (4) None of the above

Answer : The speed of a three-phase induction motor is controlled by variable voltage variable frequency control (i.e. keeping V/f constant). As the frequency is reduced, the slip at maximum torque Increases 

Description : Torque developed by a three-phase, 400V, induction motor is 100 N -m. If the applied voltage is reduced to 200-V, the d'veloped torque will be

Answer : Torque developed by a three-phase, 400V, induction motor is 100 N -m. If the applied voltage is reduced to 200-V, the d'veloped torque will be 25 N -m

Description : The slip of 400 V, three phase, 4 -pole induction motor when rotating at 1440 rpm is 

Answer : The slip of 400 V, three phase, 4 -pole induction motor when rotating at 1440 rpm is 4 percent

Description : A 400 V, 50 Hz three-phase induction motor rotates at 1440 rpm on full -load. The motor is wound for

Answer : A 400 V, 50 Hz three-phase induction motor rotates at 1440 rpm on full -load. The motor is wound for 4 poles

Description : In a split-phase induction motor, the resistance/reactance ratios of windings are such that (A) current in the auxiliary winding leads the current in the main winding (B) current in the ... (C) both windings develop the same starting torque (D) both windings develop high starting current

Answer : In a split-phase induction motor, the resistance/reactance ratios of windings are such that current in the auxiliary winding leads the current in the main winding

← Prev Question Next Question →
Ask a Question
Choose topic