search
person

1 Answer

The range of efficiency for shaded pole motors is 5% to 35%.

thumb_up_alt 0 like thumb_down_alt 0 dislike

Related questions

Answer : A shaded pole motor can be used for toys, hair dryers, circulators etc.

Answer : In case of a shaded pole motor the direction of rotation of the motor is from main pole to shaded pole.

Answer : In a shaded pole single-phase motor, the revolving field is produced by the use of shading coils.

Answer : In a shaded pole motor, the shading coil usually consist of a single turn of heavy copper wire which is short-circuited and carries only induced current.

Answer : The shaded pole motor is used for low starting torque.

Description : With a neat sketch give the working of shaded pole induction motor.

Answer : Explanation: It has squirrel cage rotor and salient pole stator. The stator poles are shaded partially by short circuited conductor band to create the phase difference between the fluxes emerging from shaded ... rotating magnetic field in the air-gap and torque is exerted on the squirrel cage rotor.

Description : State two applications of 1) Shaded pole motor 2) Universal motor

Answer : (i)Applications of Shaded pole motor: 1. Small fans 2. Toy motors 3. Hair dryers 4. Ventilators 5. Electric clocks 6. Record players 7. Motorized valves 8. Gramophones 9. Photocopying ... 5. Portable Drilling Machines 6. Electric Shavers 7. Mechanical computing Machines 8. Machine Tools etc.

Answer : Locked rotor current of a shaded pole motor is slightly more than full load current.

Answer : The torque produced in induction type relay (shaded pole structure) is inversely proportional to the square of the current.

Answer : The efficiency of a properly designed synchronous motor will usually fall in range 85 to 95%.

Answer : The wattage rating for a ceiling fan motor will be in the range 50 to 150 W .

Answer : In a capacitor start and run motors the function of the running capacitor in series with the auxiliary winding is to improve power factor.

Answer : In capacitor start single-phase motors current in the starting winding leads the voltage.

Description : 3 phase motor  42 hp  same ratting two motors  but pole change 2 and 4 pole   tell me difference amp of both motors

Description : Which of the following test is usually conducted to determine the efficiency of traction motors ? (A) Field’s test (B) Swinburne’s test (C) Hopkinson’s test (D) Retardation test.

Answer : Which of the following test is usually conducted to determine the efficiency of traction motors ? (A) Field’s test (B) Swinburne’s test (C) Hopkinson’s test (D) Retardation test.

Description : State the advantages of instrument transformer in using for extension of range of meters. 

Answer : Advantages of instrument transformer: 1. Extension of instrument range is possible. 2. Isolation of instruments from high voltage side. 3. Power loss is less as compared to shunts and multipliers. 4 ... measurement. 5. It is economical method of range extension. 6. Increases in safety of operator.

Description : State the range for low and medium resistance.

Answer : Low resistances: less than 1 ohm.  Medium resistances: 1 ohm to 0.1 Mega ohm. 

Description : For arc welding current range is usually  (1) 10 to 15 A (2) 30 to 40 A (3) 50 to 100 A (4) 100 to 350 A

Answer : For arc welding current range is usually 100 to 350 A

Answer : For diesel locomotives the range of horsepower is 1500 to 2500.

Description : Salient pole rotor is use for which speed?

Answer : Salient pole rotor is use for low and medium speed prime movers.

Description : State RADAR range equation and write factor influencing maximum range.

Answer : Free Space RADAR range Equation: 1.RADAR range equation relates the range of a RADAR to the chara. Of Tx, Rx, Antenna, target & environment. 2.Free space means RADAR and target are isolated in ... is no obstacle between RADAR antenna & the target. 4.There will be No absorption of EM waves.

Description : Define: i) Range ii) Span of instruments

Answer : i) Range: It is defined as the difference between Greatest and Smallest value of the data or reading of the instrument.  ii) Span: It is defined as the algebraic difference between the upper and lower range values

Description : How range of A.C. ammeter & A.C. voltmeter is extended? Draw suitable diagram.

Answer : Extension of A.C. Ammeter Range: The range of a.c. ammeter can be extended by using CT, the arrangement is shown in figure. The CT is current transformer having less number of primary turns carrying high ... high magnitude of source voltage. In this way range of a.c. voltmeter can be extended.

Description : List two types of oscillator, which generates frequency in RF range.

Answer : Types of Oscillators generating frequencies in RF range: i) Hartley Oscillator ii) Colpitt’s Oscillator iii) Clapp Oscillator

Description : What is the frequency range of VHF electromagnetic waves? A) 30-300 kHz B) 30-3000 kHz C) 30-300 MHz D) 30-3000 MHz

Answer : What is the frequency range of VHF electromagnetic waves? A) 30-300 kHz B) 30-3000 kHz C) 30-300 MHz D) 30-3000 MHz

Description : The range of frequencies used in induction heating is :  (A) 0-25 Hz  (C) less than 200 Hz  (B) 50 to 100 Hz  (D) more than 1 kHz

Answer : The range of frequencies used in induction heating is : more than 1 kHz

Answer : The braking retardation is usually in the range 10 to 15 km phps.

Description : A 50 Hz, 4 pole turboalternator rated at 20 MVA. 13.2 KV has an inertia constant H = 4 KW sec/KVA. The K.E. stored in the rotor at synchronous speed is

Answer : A 50 Hz, 4 pole turboalternator rated at 20 MVA. 13.2 KV has an inertia constant H = 4 KW sec/KVA. The K.E. stored in the rotor at synchronous speed is 80 MJ

Description : The armature current on symmetrical 3 phase short circuit of a synchronous machine (salient pole)  (A) has q -axis current only (B) has d -axis current only (C) has both d and q axis currents (D) cannot be divided between q and d axis currents

Answer : The armature current on symmetrical 3 phase short circuit of a synchronous machine (salient pole) has d -axis current only

Answer : If the field winding of an unloaded salient pole synchronous motor is open circuited, the motor will stop.

Description : what will happen when excitation of an unloaded salient pole synchronous motor suddenly gets disconnected?

Answer : When excitation of an unloaded salient pole synchronous motor suddenly gets disconnected the motor will stop.

Description : Explain MOSFET gate drive circuit and totem pole configuration.

Answer : MOSFET gate drive circuit: The turning on and turning off of MOSFET can be controlled from gate to source voltage signal. If the gate to source voltage of MOSFET exceeds threshold ... this configuration, the two switches (transistors) are used in totem pole arrangement with a comparator.

Description : Suggest electric motors for i) traction ii) crane iii) lathe machine iv) domestic fan.

Answer : i) Traction :- DC Series motor  ii) Crane :- DC Series motor  iii) Lathe machine :- 3 phase Induction motor or DC shunt motor  iv) Domestic fan :- 1 phase induction motor

Description : State factors for selection of motors as drive.

Answer : Following Factors governing / or are considered while selecting electric drive (Motor) for particular application: Factors to be considered for selection of Electrical Drives: 1) Nature of Supply:- ... level, load equalization 7) Cost: - Capital, Running and maintenance cost should be less.

Description : What are the factors to be considered while selection of motors for different drives?

Answer : Following Factors are considered while selecting electric drive (Motor) for particular application:  Factors to be considered for selection of Electrical Drives:  1) Nature of Supply:- Whether supply ... , load equalization 7) Cost: - Capital, Running and maintenance cost should be less.  

Description : A relay used for protection of motors against overload is :  (A) Impedance relay (B) Electromagnetic attraction type (C) Thermal relay (D) Buchholz's relay

Answer : A relay used for protection of motors against overload is : Thermal relay

Answer : D.C. shunt motors are used for driving machine tools.

Answer : The D.C. motors preferred for traction applications beacuse the speed is inversely proportional to the torque and the torque is proportional to square of armature current.

Answer : A direct online starter is used for starting motors up to 5 H.P.

Answer : As hysteresis motors are free from mechanical and magnetic vibrations therefore these are considered as suitable for sound equipment.

Answer : The standard full-load power factor ratings for synchronous motors are unity or 0.8 leading.

Answer : For power factor correction, synchronous motors operate at no-load and greatly over-excited fields.

Description : method for improving string efficiency 

Answer : The Methods of Improving String Efficiency:-   1) By reducing value of ‘m’ or (‘k’) by using longer cross arm. 2) By Making of ‘m’ or (‘k’) equal to zero 3) By grading Insulator. 4) By Using guard ring.

Description : For high efficiency of transfer of power, internal resistance of the source should be?

Answer : For high efficiency of transfer of power, internal resistance of the source should be less than the load resistance.

Answer : D.C. generators are normally designed for maximum efficiency around full-load.

Answer : The condition for maximum efficiency for a D.C. generator is variable losses equal to constant losses.

Answer : Generators for peak load plants are usually designed for maximum efficiency at 50 to 75 percent full load.

Description : For a transformer, operating at constant load current, maximum efficiency will occur at?

Answer : For a transformer, operating at constant load current, maximum efficiency will occur at unity power factor.

Answer : String efficiency is used for measuring the degree of utilization of SCR.

Description : Why are DC motors used in trains and not AC motors ?

Answer : The reason is torque. torque is inversely proportional to speed..i.e when th knowe train comes to rest position to motion.. initial speed is zero..so it requires high starting torque for ... current will flow through field and armature coils then maximum torque is available at the intial condition.

← Prev Question Next Question →