Ask or Answer

🏠 Home🏷️ Tags❔ Ask a Question✔️ Answer a QuestionUsers
46 views

Please log in or register to answer this question.

1 Answer

Answer :

Burning out of windings is due to short circuited capacitor.

Like 0 like

Related Questions

233 views

Description : In dc machines, the armature windings are placed on the rotor because of the necessity for  (1) electromechanical energy conversion (2) generation of voltage (3) commutation (4) development of torque

Last Answer : 3  Commutation

2 answers
84 views

Description : In a DC generator the windings of interpoles are connected :  (A) in series with main field winding, to create a pole,of same polarity as the main pole ahead in the direction of rotation.  ... winding, to create a pole of opposite polarity as the main pole ahead in the direction of rotation.

Last Answer : In a DC generator the windings of interpoles are connected :  in series with the armature winding, to create a pole of same polarity as the main pole ahead in the direction of rotation. 

1 answer
119 views

Last Answer : Compensating windings are used in D.C. generators to neutralise the cross-magnetising effect of the armature reaction.

1 answer
63 views

Description : Electrical fault between two windings of same phase of a generator having double star winding can be detected by the following protection in a generator:

Last Answer : Electrical fault between two windings of same phase of a generator having double star winding can be detected by the following protection in a generator: inter turn fault protection

1 answer
18 views

Description : The high strength of rapid hardening cement at early stage, is due to its (A) Finer grinding (B) Burning at high temperature (C) Increased lime cement (D) Higher content of tricalcium

Last Answer : Answer: Option C

1 answer
0 views

Description : The engine produces dark black smoke due to a) Burning of oil b) Due of incomplete combustion c) Due to moisture in fuel d) None of these Ans. b

Last Answer : ans b

1 answer
2 views

Description : A newly married girl comes to gynae OPD with history of dysuria, burning, micturition and sore perineum. What is your likely diagnosis: a) Trichomonas vaginalis. b) Candida infection. c) Trauma due to coitus. d) Honey moon cystitis. e) Genital herpes.

Last Answer : d) Honey moon cystitis.

1 answer
1 view

Description : On a cold winter night , the process sleeping in a room with closed door and windows with coal fire burning inside may die due to the excessive accumulation of a) nitrogen monoxide b) nitrogen dioxide c) carbon dioxide d) carbon monoxide

Last Answer : d) carbon monoxide

1 answer
13 views

Description : In hydel power station, the motion produced in turbines is due to (1) flow of water (2) burning of coal (3) burning of diesel (4) production of steam

Last Answer : flow of water

1 answer
79 views

Description : Which statement out of the following is a wrong statement with regard to Induction motor? A) Auto-transformer starter is costlier to direct on line (DOL) starter B) DOL starter is used for ... Star delta starter connects the motor first in delta at the time of starting then in star for running

Last Answer : Which statement out of the following is a wrong statement with regard to Induction motor? A) Auto-transformer starter is costlier to direct on line (DOL) starter B) DOL starter is used for ... delta starter connects the motor first in delta at the time of starting then in star for running

1 answer
1 view

Description : Pick out the wrong statement. (A) Theoretical flame temperature is the temperature attained by the products of combustion, when the fuel is burned without loss or gain of heat (B) ... flame temperature (D) Adiabatic flame temperatures of actual combustions are always less than the maximum values

Last Answer : (C) Burning the fuel with excess pure oxygen results in maximum theoretical flame temperature

1 answer
Show MoreAsk QuestionNext Page →