A capacitor-start single phase induction motor is switched on to supply with its capacitor replaced by an inductor of equivalent reactance value. It will?

Show More Ask Question

1 Answer

Answer :

A capacitor-start single phase induction motor is switched on to supply with its capacitor replaced by an inductor of equivalent reactance value. It will not start at all.

Like 0 like
Next Page →

Related

Description : Explain the working of a single phase capacitor start induction motor. 

Answer : Single phase capacitor start induction motor https://youtu.be/31lvvzU5Puc

Answer : Single phase induction motor usually operates on 0.6 power factor lagging.

Description : What is the slip (as a percentage) when a 6 pole single phase induction motor operating on 220 V and 60 Hz is rotating at speed of 1140 rpm? A) 60% B) 5% C) 10% D) None of these

Answer : What is the slip (as a percentage) when a 6 pole single phase induction motor operating on 220 V and 60 Hz is rotating at speed of 1140 rpm? A) 60% B) 5% C) 10% D) None of these

Description : Why is a capacitor used in a single phase motor and not in three phase motor ?

Answer : In 1-phase induction motor capacitor work is generate the auxiliary winding current than excite the main winding to rotor starts rotate. After rotor start rotating about 75% of their speed than auxiliary ... emf to start the motor.so,in 3-phase induction motor is self start induction motor.