The value of starting capacitor of a fractional horse power motor will be 300 uF .

thumb_up_alt 0 like thumb_down_alt 0 dislike
← Prev Question Next Question →

Related questions

Description :

Answer :

In a capacitor start motor, the phase displacement between starting and running winding can be nearly 90°.

thumb_up_alt 0 like thumb_down_alt 0 dislike
146 views 1 answer
Description :

Answer :

In a two value capacitor motor, the capacitor used for running purposes is paper spaced oil filled type.

thumb_up_alt 0 like thumb_down_alt 0 dislike
89 views 1 answer
Description :

A capacitor-start single phase induction motor is switched on to supply with its capacitor replaced by an inductor of equivalent reactance value. It will?

Answer :

A capacitor-start single phase induction motor is switched on to supply with its capacitor replaced by an inductor of equivalent reactance value. It will not start at all.

thumb_up_alt 0 like thumb_down_alt 0 dislike
124 views 1 answer
Description :

Answer :

A centrifugal switch is used to disconnect starting winding when motor has picked up about 50 to 70 per cent of rated speed.

thumb_up_alt 0 like thumb_down_alt 0 dislike
256 views 1 answer
Description :

Answer :

The rotor developed by a single-phase motor at starting is zero.

thumb_up_alt 0 like thumb_down_alt 0 dislike
64 views 1 answer
Description :

Answer :

If starting winding of a single-phase induction motor is left in the circuit, it will draw excessive current and overheat.

thumb_up_alt 0 like thumb_down_alt 0 dislike
205 views 1 answer
Description :

Answer :

In a capacitor start single-phase motor, when capacitor is replaced by a resistance motor will continue to run in same direction.

thumb_up_alt 0 like thumb_down_alt 0 dislike
97 views 1 answer
Description :

Answer :

If the capacitor of a single-phase motor is short-circuited the motor will not start.

thumb_up_alt 0 like thumb_down_alt 0 dislike
90 views 1 answer
Description :

A synchronous motor can be made self starting by providing?

Answer :

A synchronous motor can be made self-starting by providing damper bar.

thumb_up_alt 0 like thumb_down_alt 0 dislike
111 views 1 answer
Description :

Answer :

For high value of diversity factor, a power station of given installed capacity will be in a position to supply more number of consumers.

thumb_up_alt 0 like thumb_down_alt 0 dislike
117 views 1 answer
Description :

Answer :

When a D.C. series motor is connected to A.C. supply, the power factor will be low because of high inductance of field and armature circuits.

thumb_up_alt 0 like thumb_down_alt 0 dislike
105 views 1 answer
Description :

Answer :

If the centrifugal switch of a two-value capacitor motor using two capacitors fails to open then Electrolytic capacitor will, in all probability, suffer break down.

thumb_up_alt 0 like thumb_down_alt 0 dislike
101 views 1 answer
Description :

Answer :

Two-value capacitor motor finds increased application as compressor motor in small home air-conditioners because it has low starting as well as running currents at relatively high power factor.

thumb_up_alt 0 like thumb_down_alt 0 dislike
61 views 1 answer
Description :

In a double squirrel cage induction motor, good starting torque is produced as (A) Large current flows through the outer high resistance winding. (B) Large current flows through the inner high resistance winding. (C) Small current flows through the outer high resistance winding. (D) Large current flows through the inner low resistance winding.

Answer :

In a double squirrel cage induction motor, good starting torque is produced as Large current flows through the outer high resistance winding.

thumb_up_alt 0 like thumb_down_alt 0 dislike
98 views 1 answer
Description :

Answer :

The starting resistance of a D.C. motor is generally low.

thumb_up_alt 0 like thumb_down_alt 0 dislike
89 views 1 answer
Description :

Answer :

For starting a D.C. motor a starter is required because it limits the starting current to a safe value.

thumb_up_alt 0 like thumb_down_alt 0 dislike
66 views 1 answer
Description :

Answer :

The starting winding of a single-phase motor is placed in stator.

thumb_up_alt 0 like thumb_down_alt 0 dislike
72 views 1 answer
Description :

Answer :

Starting winding of a single phase motor of a refrigerator is disconnected from the circuit by means of a magnetic relay.

thumb_up_alt 0 like thumb_down_alt 0 dislike
177 views 1 answer
Description :

How is a three phase cage induction motor self starting?

Answer :

Any type of induction motor is self starting. Because the reason for torqe production require two flux displaced by some angle theta.If theta is constant with time then torqe will be constant;if ... torqe also pulsating. In induction motor this angle theta is not pulsating.so it is self starting 

thumb_up_alt 0 like thumb_down_alt 0 dislike
104 views 1 answer
Description :

Why a dc series motor has a high starting torque?

thumb_up_alt 0 like thumb_down_alt 0 dislike
69 views 0 answers
Description :

List different starting methods of three phase synchronous motor. Explain any one of them.

Answer :

Different Starting Methods of Three Phase Synchronous Motor: As synchronous motor is not self starting, different methods of starting are as follows: 1) By using an Induction (Pony) motor 2) ... . The rotor gets pulled into synchronism and starts running at constant speed as a synchronous motor. 

thumb_up_alt 0 like thumb_down_alt 0 dislike
77 views 1 answer
Description :

Answer :

For the same H.P. rating and full load speed, following motor has poor starting torque differentially compounded.

thumb_up_alt 0 like thumb_down_alt 0 dislike
124 views 1 answer
Description :

Is induction motor is self starting?

Answer :

Single phase induction motor is not self starting. Three phase induction motor is self starting.

thumb_up_alt 0 like thumb_down_alt 0 dislike
97 views 1 answer
Description :

Why starter is required for starting an induction motor?

thumb_up_alt 0 like thumb_down_alt 0 dislike
102 views 0 answers
Description :

Why does induction motor have high starting current?

Answer :

In induction motor , the flux produce is quadrature to the applied voltage. Since when we are going to start motor , there is no flux present inside . So in order to lets say compensate it ... times of current to further increase flux. So that is reason for high starting current in induction motor

thumb_up_alt 0 like thumb_down_alt 0 dislike
122 views 2 answers
Description :

Answer :

Capacitor start motor has high torque in starting

thumb_up_alt 0 like thumb_down_alt 0 dislike
97 views 1 answer
Description :

Answer :

The operating speed of a synchronous motor can be changed to new fixed value by changing frequency.

thumb_up_alt 0 like thumb_down_alt 0 dislike
92 views 1 answer
Description :

Explain starting system in diesel electric power plant.

Answer :

Starting system in Diesel Electric Power Plant: It includes Storage battery, compressed air tanks, self-starter etc. The purpose of engine starting system is to rotate the engine initially while ... as Ammeters, Voltmeters, Wattmeters, Thermometers, Pressure gauges, Visible and audible alarm etc.

thumb_up_alt 0 like thumb_down_alt 0 dislike
51 views 1 answer
Description :

Why is a capacitor used in a single phase motor and not in three phase motor ?

Answer :

In 1-phase induction motor capacitor work is generate the auxiliary winding current than excite the main winding to rotor starts rotate. After rotor start rotating about 75% of their speed than auxiliary ... emf to start the motor.so,in 3-phase induction motor is self start induction motor.

thumb_up_alt 0 like thumb_down_alt 0 dislike
138 views 6 answers
Description :

Explain the working of a single phase capacitor start induction motor. 

Answer :

Single phase capacitor start induction motor https://youtu.be/31lvvzU5Puc

thumb_up_alt 0 like thumb_down_alt 0 dislike
195 views 2 answers
Description :

Answer :

To reverse the direction of rotation of a capacitor start motor while it is running we should disconnect motor from the supply till it stops then reconnect it to supply with reversed connection of main or auxiliary winding.

thumb_up_alt 0 like thumb_down_alt 0 dislike
91 views 1 answer
Description :

Answer :

In a ceiling fan employing capacitor run motor secondary winding surrounds the primary winding.

thumb_up_alt 0 like thumb_down_alt 0 dislike
90 views 1 answer
Description :

Can we use the synchronous motor as the synchronous capacitor?

Answer :

Yes, we can use the synchronous motor as the synchronous capacitor when the synchrnous motor is overexcited.

thumb_up_alt 0 like thumb_down_alt 0 dislike
81 views 1 answer
Description :

What is the maximum value of power factor?

Answer :

1 is the maximum value of power factor.

thumb_up_alt 0 like thumb_down_alt 0 dislike
88 views 1 answer
Description :

What is the value of Beta in power BJT?

Answer :

The beta value in power BJT is 5 to 10.

thumb_up_alt 1 like thumb_down_alt 0 dislike
90 views 1 answer
Description :

How does a capacitor improve power factor?

Answer :

Every circuit are usually more inductive than capacitive.it means that the current lags by voltage at small angle.hence we have to compensate this situation so we use Capacitor then this lag is compensate ... angle becomes low and the value of cos(phase angle) is increase and hence power also max.

thumb_up_alt 4 like thumb_down_alt 0 dislike
143 views 1 answer
Description :

Answer :

The power factor of a single-phase induction motor is usually lagging.

thumb_up_alt 0 like thumb_down_alt 0 dislike
121 views 1 answer
Description :

Power factor of an inductive circuit is usually improved by connecting capacitor to it in?

Answer :

Power factor of an inductive circuit is usually improved by connecting capacitor to it in parallel.

thumb_up_alt 0 like thumb_down_alt 0 dislike
182 views 1 answer
Description :

Answer :

The mechanical power developed by a shunt motor will be maximum when the ratio of back e.m.f. to applied voltage is 0.5.

thumb_up_alt 0 like thumb_down_alt 0 dislike
170 views 1 answer
Description :

Answer :

In a D.C. shunt motor, under the conditions of maximum power, the current in the armature will be more than full-load current.

thumb_up_alt 0 like thumb_down_alt 0 dislike
215 views 1 answer
Description :

Answer :

In D.C. machines fractional pitch winding is used to reduce the sparking.

thumb_up_alt 0 like thumb_down_alt 0 dislike
326 views 1 answer
Description :

Answer :

Most of the fractional horsepower motors have either plain or sleeve bearings.

thumb_up_alt 0 like thumb_down_alt 0 dislike
75 views 1 answer
Description :

If the field of synchronous motor is under excited, power factor will be?

Answer :

If the field of synchronous motor is under excited, power factor will be lagging.

thumb_up_alt 0 like thumb_down_alt 0 dislike
219 views 1 answer
Description :

If the load of the normally excited synchronous motor is increased the power factor will?

Answer :

If the load of the normally excited synchronous motor is increased the power factor will become lagging.

thumb_up_alt 0 like thumb_down_alt 0 dislike
115 views 1 answer
Description :

The synchronous motor will develop maximum power when the load angle is?

Answer :

The synchronous motor will develop maximum power when the load angle is 900.

thumb_up_alt 0 like thumb_down_alt 0 dislike
93 views 1 answer
Description :

Answer :

In a capacitor start and run motors the function of the running capacitor in series with the auxiliary winding is to improve power factor.

thumb_up_alt 0 like thumb_down_alt 0 dislike
510 views 1 answer
Description :

Answer :

In capacitor start single-phase motors current in the starting winding leads the voltage.

thumb_up_alt 0 like thumb_down_alt 0 dislike
66 views 1 answer
Description :

Answer :

The value of co-efficient of adhesion will be high when rails are cleaned with sand.

thumb_up_alt 0 like thumb_down_alt 0 dislike
74 views 1 answer
Description :

The maximum reluctance power of a salient-pole synchronous motor having direct-axis reactance, 1.0 pu and quadrature-axis reactance, 0.5 pu, and input voltage, 1.0 pu is (A) 0.25 pu (B) 0.5 pu (C) 1.0 pu (D) 1.5 pu

Answer :

The maximum reluctance power of a salient-pole synchronous motor having direct-axis reactance, 1.0 pu and quadrature-axis reactance, 0.5 pu, and input voltage, 1.0 pu is 0.5 pu

thumb_up_alt 0 like thumb_down_alt 0 dislike
82 views 1 answer
Description :

In a d.c. motor, the mechanical output power actually comes from?

Answer :

In a d.c. motor, the mechanical output power actually comes from electrical input power.

thumb_up_alt 0 like thumb_down_alt 0 dislike
1.1k views 1 answer
editAsk a Question
...