search
person

1 Answer

In a shaded pole motor, the shading coil usually consist of a single turn of heavy copper wire which is short-circuited and carries only induced current.

thumb_up_alt 0 like thumb_down_alt 0 dislike

Related questions

Answer : In case of a shaded pole motor the direction of rotation of the motor is from main pole to shaded pole.

Answer : In a shaded pole single-phase motor, the revolving field is produced by the use of shading coils.

Answer : A shaded pole motor can be used for toys, hair dryers, circulators etc.

Description : With a neat sketch give the working of shaded pole induction motor.

Answer : Explanation: It has squirrel cage rotor and salient pole stator. The stator poles are shaded partially by short circuited conductor band to create the phase difference between the fluxes emerging from shaded ... rotating magnetic field in the air-gap and torque is exerted on the squirrel cage rotor.

Description : State two applications of 1) Shaded pole motor 2) Universal motor

Answer : (i)Applications of Shaded pole motor: 1. Small fans 2. Toy motors 3. Hair dryers 4. Ventilators 5. Electric clocks 6. Record players 7. Motorized valves 8. Gramophones 9. Photocopying ... 5. Portable Drilling Machines 6. Electric Shavers 7. Mechanical computing Machines 8. Machine Tools etc.

Answer : Locked rotor current of a shaded pole motor is slightly more than full load current.

Answer : The shaded pole motor is used for low starting torque.

Answer : The range of efficiency for shaded pole motors is 5% to 35%.

Answer : The torque produced in induction type relay (shaded pole structure) is inversely proportional to the square of the current.

Answer : The power factor of a single-phase induction motor is usually lagging.

Answer : In a A.C. series motor armature coils are usually connected to commutator through resistance.

Answer : The efficiency of a properly designed synchronous motor will usually fall in range 85 to 95%.

Answer : If the field winding of an unloaded salient pole synchronous motor is open circuited, the motor will stop.

Description : what will happen when excitation of an unloaded salient pole synchronous motor suddenly gets disconnected?

Answer : When excitation of an unloaded salient pole synchronous motor suddenly gets disconnected the motor will stop.

Answer : The adjustment of position of shading bands, in an energy meter is done to provide friction compensation.

Description : State the function of overload coil and No volt coil in dc motor starter.

Answer : Function of Overload Coil: When DC motor is overloaded, the overload coil carries the overload current and produces strong magnetic field to attract a plunger, which short the terminals of ... dc motor is prevented from restarting automatically on recovery of supply without starter and protected.

Description : Power factor of an inductive circuit is usually improved by connecting capacitor to it in?

Answer : Power factor of an inductive circuit is usually improved by connecting capacitor to it in parallel.

Answer : The braking retardation is usually in the range 10 to 15 km phps.

Answer : The voltage used for suburban trains in D.C. system is usually 600 to 750 V.

Answer : Single phase induction motor usually operates on 0.6 power factor lagging.

Answer : The motor used on small lathes is usually single-phase capacitor run motor.

Answer : Overload capacity of diesel engines is usually restricted to 2 percent.

Description : A 50 Hz, 4 pole turboalternator rated at 20 MVA. 13.2 KV has an inertia constant H = 4 KW sec/KVA. The K.E. stored in the rotor at synchronous speed is

Answer : A 50 Hz, 4 pole turboalternator rated at 20 MVA. 13.2 KV has an inertia constant H = 4 KW sec/KVA. The K.E. stored in the rotor at synchronous speed is 80 MJ

Description : The armature current on symmetrical 3 phase short circuit of a synchronous machine (salient pole)  (A) has q -axis current only (B) has d -axis current only (C) has both d and q axis currents (D) cannot be divided between q and d axis currents

Answer : The armature current on symmetrical 3 phase short circuit of a synchronous machine (salient pole) has d -axis current only

Description : Salient pole rotor is use for which speed?

Answer : Salient pole rotor is use for low and medium speed prime movers.

Description : Explain MOSFET gate drive circuit and totem pole configuration.

Answer : MOSFET gate drive circuit: The turning on and turning off of MOSFET can be controlled from gate to source voltage signal. If the gate to source voltage of MOSFET exceeds threshold ... this configuration, the two switches (transistors) are used in totem pole arrangement with a comparator.

Description : Name the material used for :- (i) Moving coil (ii) Permanent magnet in PMMC instrument.

Answer : (i) Material used for Moving coil: Copper, Aluminum( some times)  (ii) Permanent magnets are made of special alloys such as :  Aluminum-Nickel-Cobalt (Alnicos)  Strontium-Iron  Neodymium-Iron-Boron  Samarium-Cobalt.

Description : The purpose of the restraining coil in a biased differential relay is  (A) To reduce CT saturation during fault.  (B) To increase the sensitivity of the relay.  (C) To match the transformation ratio.  (D) To limit the spill current through the relay during heavy external fault.

Answer : d

Answer : In a low power factor wattmeter the compensating coil is connected in series with pressure coil.

Answer : In a low power factor wattmeter the pressure coil is connected to the load side of the current coil.

Answer : The multiplier and the meter coil in a voltmeter are in series.

Description : State the material used for moving coil and former for PMMC instruments. 

Answer : Material Used for Moving Coil and Former for PMMC Instruments:  Material used for moving coil: Copper  Material used for Former: Aluminium

Description : Permanent magnet moving coil instruments are used for

Answer : PMME are mostly used for measuring voltage and current.

Description : Peterson coil is used for :  (A) shunt compensation of lines (B) grounding of system neutral (B) reduce fault currents (D) connecting interconnected systems

Answer : Peterson coil is used for : grounding of system neutral

Description : A moving coil of meter has 100 turns, and a length and depth of 10mm and 20mm respectively. It is positioned in a uniform radial flux density of 200 mT. The coil carrier current capacity is 50 mA. The torque on the coil is

Answer : A moving coil of meter has 100 turns, and a length and depth of 10mm and 20mm respectively. It is positioned in a uniform radial flux density of 200 mT. The coil carrier current capacity is 50 mA. The torque on the coil is 200µNm

Description : A Peterson coil is ________ A) An arc generating coil B) An arc suppressing coil C) An arc inducing coil D) None of these

Answer : A Peterson coil is An arc suppressing coil

Description : The self inductance of a coil can be measured using (A) Wien’s Bridge (B) Schering Bridge (C) Anderson’s Bridge (D) Wheatstone Bridge

Answer : The self inductance of a coil can be measured using Anderson’s Bridge

Description : A PMMC instrument has FSD of 100 μA and a coil resistance of 1 kΩ. To convert the instrument into an ammeter with full scale deflection of 100 mA, the required shunt resistance is (A) 1 Ω (B) 1.001 Ω (C) 0.5 Ω (D) 10 Ω

Answer : A PMMC instrument has FSD of 100 μA and a coil resistance of 1 kΩ. To convert the instrument into an ammeter with full scale deflection of 100 mA, the required shunt resistance is 1.001 Ω

Description : A moving coil meter has a resistance of 3 Ω and gives full scale deflection with 30 mA. To measure voltage up to 300 V, the external resistance to be connected in series with the instrument is (A) 9997 Ω (B) 10000 Ω (C) 997 Ω (D) 10003 Ω

Answer : A moving coil meter has a resistance of 3 Ω and gives full scale deflection with 30 mA. To measure voltage up to 300 V, the external resistance to be connected in series with the instrument is 9997 Ω

Description : lt the length, number of turns and area of a coil are  doubled, the inductance of the coil

Answer : lt the length, number of turns and area of a coil are  doubled, the inductance of the coil is quadrupled

Description : The potential coil of a single phase dynamometer wattmeter has 4840 Ohm resistance. Voltage across the load is 220 V. With the potential coil connected on the load side, the meter indicates 100 W. Approximate percentage error due to wattmeter connection is (A) 11% (B) 9% (C) 1.1% (D) 3%

Answer : The potential coil of a single phase dynamometer wattmeter has 4840 Ohm resistance. Voltage across the load is 220 V. With the potential coil connected on the load side, the meter indicates 100 W. Approximate percentage error due to wattmeter connection is 11%

Description : The initial rate of rise of current through a coil of inductance 10 H when suddenly connected to a D.C. supply of 200 V is_______Vs.

Answer : The initial rate of rise of current through a coil of inductance 10 H when suddenly connected to a D.C. supply of 200 V is 20 Vs

Description : The rate of rise of current through an inductive coil is maximum?

Answer : The rate of rise of current through an inductive coil is maximum at the start of the current flow.

Description : The inductance of a coil can be increased by?

Answer : The inductance of a coil can be increased by choosing core material having high relative permeability.

Description : Inductance of coil?

Answer : Inductance of coil increases with the increase in supply frequency.

Description : Inductance of a coil Varies?

Answer : Inductance of a coil Varies as directly as the cross-sectional area of magnetic core and inversely as the length of the iron path.

Answer : A moving-coil permanent-magnet instrument can be used as flux-meter by eliminating the control springs.

Answer : A moving-coil permanent-magnet instrument can be used as ammeter by using a low resistance shunt.

Answer : Armature coil is short circuited by brushes when it lies along neutral axis.

Answer : Open circuited armature coil of a D.C. machine is identified by the scarring of the commutator segment to which open circuited coil is connected and indicated by a spark completely around the commutator.

← Prev Question Next Question →