1 Answer

In a capacitor start and run motors the function of the running capacitor in series with the auxiliary winding is to improve power factor.

Like 0 like Dislike 0 dislike

Related questions

Answer : In a capacitor start motor, the phase displacement between starting and running winding can be nearly 90°.

Answer : In capacitor start single-phase motors current in the starting winding leads the voltage.

Answer : In split-phase motor auxiliary winding is of thin wire placed at the top of the slots.

Answer : The repulsion-start induction-run motor is used because of high starting torque.

Description : The running winding of a single phase motor on testing with meggar is found to be ground. Most probable location of the ground will be?

Answer : The running winding of a single phase motor on testing with meggar is found to be ground. Most probable location of the ground will be at the slot edge where coil enters or comes out of the slot.

Answer : In a split phase motor, the running winding should have low resistance and high inductance.

Answer : Centrifugal switch disconnects the auxiliary winding of the motor at about 70 to 80 percent of synchronous speed.

Answer : To reverse the direction of rotation of a capacitor start motor while it is running we should disconnect motor from the supply till it stops then reconnect it to supply with reversed connection of main or auxiliary winding.

Answer : In a capacitor start single-phase motor, when capacitor is replaced by a resistance motor will continue to run in same direction.

Answer : In a two value capacitor motor, the capacitor used for running purposes is paper spaced oil filled type.

Answer : In A.C. series motor compensating winding is employed to reduce sparking at the brushes.

Description : In case of conductively compensated D.C. series motors, the compensating winding is provided?

Answer : In case of conductively compensated D.C. series motors, the compensating winding is provided in series with armature winding.

Description : A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is

Answer : A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is 36 Ohm

Answer : In a ceiling fan employing capacitor run motor secondary winding surrounds the primary winding.

Description : Explain the working of a single phase capacitor start induction motor. 

Answer : Single phase capacitor start induction motor https://youtu.be/31lvvzU5Puc

Description : Damper winding is provided in 3 phase synchronous motors to :

Answer : Damper winding is provided in 3 phase synchronous motors to : provide starting torque and prevent hunting

Answer : The capacitors used in single-phase capacitor motors have no polarity marking.

Answer : When two D.C. series motors are connected in parallel, the resultant speed is normal speed.

Answer : During rheostat braking of D.C. series motors motor is run as a generator.

Description : What is the basic function of a capacitor?

Description : Series and parallel capacitor problem

Answer : Series and parallel capacitor problem 1 : https://youtu.be/MSl5mRwtjAE Series and parallel capacitor problem 2 : https://youtu.be/yGwbpyEtIyw Series and parallel capacitor problem 3 : https:// ... https://youtu.be/_7KwEwWqiNU Series and parallel capacitor problem 10 : https://youtu.be/et8MCWV_OyE

Description : A capacitor-start single phase induction motor is switched on to supply with its capacitor replaced by an inductor of equivalent reactance value. It will?

Answer : A capacitor-start single phase induction motor is switched on to supply with its capacitor replaced by an inductor of equivalent reactance value. It will not start at all.

Answer : A universal motor can run on either A.C. or D.C.

Answer : A schrage motor can run on zero slip, negative slip, positive slip.

Description : Explain auxiliary commutation with a neat diagram. Also draw its waveform.

Answer : Auxiliary Commutation At start, the Ta is triggered and turned on to carry the load current. Due to the resonant circuit R-L-C, the current initially rises, attains peak and then falls to ... , the firing of auxiliary SCR commutates the main SCR, hence name is auxiliary commutation.

Description : What is the purpose of auxiliary controller in substation?

Answer : The systems of substation auxiliaries ensure operation of substations providing internal consumers of substations with operating direct and alternating currents. Any breakdown (loss) of auxiliary systems ... whole substation, as well as serious problems during its subsequent putting into operation.

Description : Generally, Crawling in squirrel cage induction motors is tendency to run stably at speeds as low as (A) One-third of their synchronous speed (B) One-fifth of their synchronous speed (C) One-seventh of their synchronous speed (D) One-ninth of their synchronous speed

Answer : Generally, Crawling in squirrel cage induction motors is tendency to run stably at speeds as low as One-seventh of their synchronous speed

Answer : A centrifugal switch is used to disconnect starting winding when motor has picked up about 50 to 70 per cent of rated speed.

Description : Which of the following motors can run on both AC and DC? A) Universal motor B) Dual wattage motor C) Flexible motor D) All the above

Answer : Which of the following motors can run on both AC and DC? A) Universal motor B) Dual wattage motor C) Flexible motor D) All the above

Answer : The range of efficiency for shaded pole motors is 5% to 35%.

Description : what is TCSC?

Answer : Thyristor Controlled Series Capacitor (TCSC)

Answer : A synchronous motor running with normal excitation adjusts to load increases essentially by increase in armature current.

Description : While keeping the excitation constant, if the steam supply of an alternator running in parallel with another identical alternator is increased, then (A) It would over-run the other alternator (B) Its rotor ... (C) Its portion of share in load will increase (D) Its power factor would be decreased.

Answer : While keeping the excitation constant, if the steam supply of an alternator running in parallel with another identical alternator is increased, then Its portion of share in load will increase

Description : The effect of increasing load on a synchronous motor running with normal excitation is (A) Increase both its Ia and power factor. (B) Decrease Ia, but increase power factor. (C) Increase Ia, but decrease power factor (D) Decrease both Ia and power factor.

Answer : The effect of increasing load on a synchronous motor running with normal excitation is Increase Ia, but decrease power factor

Description : Instant 100 meters (How fast to run 100 meters?)

Answer : Instant 100 meters (How fast to run 100 meters?) This guide outlines the step-by-step preparation for the most efficient 100-meter run. 0-15 meters With your head down, you need to ... length. Constant training and the right technique will allow you to improve your 100 meter running results.

Description : Which type of heater is cheapest to run?

Answer : The value of starting capacitor of a fractional horse power motor will be 300 uF .

Answer : If the capacitor of a single-phase motor is short-circuited the motor will not start.

Answer : A rotory converter can also be run as a synchronous motor.

Description : Explain the need and steps to conduct the reduced voltage running up test on the three phase induction motor.

Answer : If the synchronous motor, properly synchronised to the supply is running on no load and is having negligible loss then the stator current will be zero.

Description : Which type of starter is used to start the DC motor?

Answer : When a D.C. series motor is connected to A.C. supply, the power factor will be low because of high inductance of field and armature circuits.

Description : What is the difference between a soft start and a VFD?

Answer : Energy conservation technique in induction motor by minimizing idle and redundant running of motor: 1) Loss of energy as the no load power drawn is approximately about 12% to 16% of rated ... to unnecessary line losses. 4) Reduction in overall system energy efficiency over period of time.

Answer : In case of main-line service free running and coasting periods are generally long.

Description : I got some grapic drawing questions guys and I need to see the answers immediately.Stator voltage curve for each four different start up methods.

Description : What is a soft start?

Description : Why synchronous motor Cannot start itself?

Answer : If  equalising bar is connected to the 2 DC generators  the current will be equal in 2 generators irrespective of parallel connection so that we connect equaliser bar