In capacitor start single-phase motors current in the starting winding leads the voltage.

thumb_up_alt 0 like thumb_down_alt 0 dislike

Related questions

Answer : In a capacitor start single-phase motor, when capacitor is replaced by a resistance motor will continue to run in same direction.

Answer : In a capacitor start and run motors the function of the running capacitor in series with the auxiliary winding is to improve power factor.

Answer : The capacitors used in single-phase capacitor motors have no polarity marking.

Answer : In a capacitor start motor, the phase displacement between starting and running winding can be nearly 90°.

Description : Explain the working of a single phase capacitor start induction motor. 

Answer : Single phase capacitor start induction motor https://youtu.be/31lvvzU5Puc

Answer : If the capacitor of a single-phase motor is short-circuited the motor will not start.

Answer : To reverse the direction of rotation of a capacitor start motor while it is running we should disconnect motor from the supply till it stops then reconnect it to supply with reversed connection of main or auxiliary winding.

Description : A capacitor-start single phase induction motor is switched on to supply with its capacitor replaced by an inductor of equivalent reactance value. It will?

Answer : A capacitor-start single phase induction motor is switched on to supply with its capacitor replaced by an inductor of equivalent reactance value. It will not start at all.

Answer : In a shaded pole single-phase motor, the revolving field is produced by the use of shading coils.

Answer : A single-phase induction motor is inherently non-self-starting with low torque.

Answer : The power factor of a single-phase induction motor is usually lagging.

Answer : The rotor developed by a single-phase motor at starting is zero.

Answer : The repulsion-start induction-run motor is used because of high starting torque.

Description : What are the five types of single phase motors used in the industry?

Answer : The range of efficiency for shaded pole motors is 5% to 35%.

Description : Why is a capacitor used in a single phase motor and not in three phase motor ?

Answer : In 1-phase induction motor capacitor work is generate the auxiliary winding current than excite the main winding to rotor starts rotate. After rotor start rotating about 75% of their speed than auxiliary ... emf to start the motor.so,in 3-phase induction motor is self start induction motor.

Description : For a single phase capacitor start induction motor, which of the following statements is valid?  A) The capacitor is used for power factor improvement B) The direction of rotation can be ... rotation cannot be changed D) The direction of rotation can be changed by interchanging the supply terminals

Answer : For a single phase capacitor start induction motor, which of the following statements is valid?  A) The capacitor is used for power factor improvement B) The direction of rotation can be ... cannot be changed D) The direction of rotation can be changed by interchanging the supply terminals

Answer : In a two value capacitor motor, the capacitor used for running purposes is paper spaced oil filled type.

Answer : The value of starting capacitor of a fractional horse power motor will be 300 uF .

Description : Damper winding is provided in 3 phase synchronous motors to :

Answer : Damper winding is provided in 3 phase synchronous motors to : provide starting torque and prevent hunting

Description : 3 phase motor  42 hp  same ratting two motors  but pole change 2 and 4 pole   tell me difference amp of both motors

Description : In a single-phase induction motor, the operating direction is determined by the ________ A) Rotor B) Stator C) Starting circuit D) None of these

Answer : In a single-phase induction motor, the operating direction is determined by the Starting circuit

Description : In a 230 V, 50 Hz single-phase SCR bridge converter operating at a firing delay angle, α and with large R-L load, the input source current is (A) sinusoidal current (B) constant dc current (C) continuous rectangular pulses (D) alternating rectangular pulses

Answer : In a 230 V, 50 Hz single-phase SCR bridge converter operating at a firing delay angle, α and with large R-L load, the input source current is alternating rectangular pulses

Description : In a single-phase induction motor when the rotor is stationary and voltage is applied to the stator, then (A) the flux is constant (B) the flux first decreases and then increases in ... increases and decreases in the opposite direction with the same magnitude (D) current flows through the rotor

Answer : In a single-phase induction motor when the rotor is stationary and voltage is applied to the stator, then the flux first decreases and then increases in the same direction

Description : In a single-phase transformer, the magnetizing current is (A) in phase with the no-load current (B) in quadrature with the no-load current (C) the product of no-load current and power factor (D) in phase with the flux in the core

Answer : In a single-phase transformer, the magnetizing current is in phase with the flux in the core

Answer : The starting winding of a single-phase motor is placed in stator.

Answer : If starting winding of a single-phase induction motor is left in the circuit, it will draw excessive current and overheat.

Description : Single-phase mid-point controlled rectifier with RL load

Answer : Single-phase mid-point controlled rectifier with RL load : The circuit configuration of single-phase midpoint controlled rectifier is shown in the figure. During positive half-cycle of ... some part of next positive half-cycle of voltage with reversed polarity can appear across load.

Description : Single-phase Midpoint controlled rectifier with Resistive load

Answer : Single-phase Midpoint controlled rectifier with Resistive load:  1) During positive half cycle of AC supply, a is positive with respect to b , this makes T1 forward biased and T2 is reverse ... voltage reverses the polarity and T2 is turned off. The operation is as shown in waveforms.

Description : When the firing angle a of a single-phase, fully controlled rectifier feeding constant direct current into a load is 30°, the displacement power factor of the rectifier is

Answer : When the firing angle a of a single-phase, fully controlled rectifier feeding constant direct current into a load is 30°, the displacement power factor of the rectifier is √3/2

Description : An additional condition for parallel operation of three-phase transformers over single-phase transformers is that

Answer : An additional condition for parallel operation of three-phase transformers over single-phase transformers is that the transformers should belong to the same vector group

Description : The no-load speed of a single-phase SCR bridge converter fed separately excited dc motor operating at a firing delay angle, α and flux, Φ (A) directly proportional to α and Φ (B) ... proportional to α and inversely proportional to Φ (D) directly proportional to Φ and inversely proportional to α

Answer : The no-load speed of a single-phase SCR bridge converter fed separately excited dc motor operating at a firing delay angle, α and flux, Φ directly proportional to α and inversely proportional to Φ

Description : A 230 V, 50 Hz phase controlled single-phase full-controlled SCR bridge converter draws 15 A constant dc current. If the source inductance is 3 mH, the drop in dc output voltage is (A) 4.5 V (B) 6.75 V (C) 9 V (D) 13.5 V

Answer : A 230 V, 50 Hz phase controlled single-phase full-controlled SCR bridge converter draws 15 A constant dc current. If the source inductance is 3 mH, the drop in dc output voltage is 9 V

Description : The sequence components of current of a single-phase load connected to a 3-phase system are (A) equal positive and negative sequence components (B) equal positive, negative and zero sequence components (C) vector sum of sequence currents is zero (D) algebraic sum of sequence currents is zero

Answer : The sequence components of current of a single-phase load connected to a 3-phase system are equal positive, negative and zero sequence components

Description : A 230 V/460 V single-phase transformer operating at 20 A and unity power factor has primary referred resistance of 0.2 Ω and reactance of 0.5 Ω. The approximate primary induced emf is (A) 216 V (B) 226 V (C) 234 V (D) 236 V

Answer : A 230 V/460 V single-phase transformer operating at 20 A and unity power factor has primary referred resistance of 0.2 Ω and reactance of 0.5 Ω. The approximate primary induced emf is 226 V

Description : I got some grapic drawing questions guys and I need to see the answers immediately.Stator voltage curve for each four different start up methods.

Description : What is the difference between a soft start and a VFD?

Description : What is a soft start?

Description : Why synchronous motor Cannot start itself?

Description : Which type of starter is used to start the DC motor?

Description : Why are DC motors used in trains and not AC motors ?

Answer : The reason is torque. torque is inversely proportional to speed..i.e when th knowe train comes to rest position to motion.. initial speed is zero..so it requires high starting torque for ... current will flow through field and armature coils then maximum torque is available at the intial condition.

Description : State which electric motors are generally used in electro agro systems with reason.

Answer : 1) 3 phase induction motor is used in electro agro system for water pumping from wells as 3 phase ac supply is easily available, cost of induction motor is less, maintenance free being rugged ... as 1 phase ac supply is easily available for domestic purpose, repair is simple and easily available.

Description : Stepper motors are used in  (1) printers (2) lifts (3) amplifiers (4) oscillators

Answer : Stepper motors are used in printers 

Description : Slot harmonics are reduced in induction motors by using (A) fractional-pitch windings (B) fractional-slot windings (C) integral-slot windings (D) distributed windings

Answer : Slot harmonics are reduced in induction motors by using fractional-slot windings

Description : Generally, Crawling in squirrel cage induction motors is tendency to run stably at speeds as low as (A) One-third of their synchronous speed (B) One-fifth of their synchronous speed (C) One-seventh of their synchronous speed (D) One-ninth of their synchronous speed

Answer : Generally, Crawling in squirrel cage induction motors is tendency to run stably at speeds as low as One-seventh of their synchronous speed

Description : Which of the following motors is being extensively used in servo applications ? A. AC motor B. Field controlled dc motor C. Armature controlled dc motor D. None of these

Answer : Which of the following motors is being extensively used in servo applications ? A. AC motor B. Field controlled dc motor C. Armature controlled dc motor D. None of these

Description : In case of conductively compensated D.C. series motors, the compensating winding is provided?

Answer : In case of conductively compensated D.C. series motors, the compensating winding is provided in series with armature winding.

Answer : In case of D.C. shunt motors the speed is dependent on back e.m.f. only because flux is practically constant in D:C. shunt motors.

Answer : When two D.C. series motors are connected in parallel, the resultant speed is normal speed.

Answer : In D.C. shunt motors as load is reduced the speed will remain almost constant.