1 Answer

Generators for peak load plants are usually designed for maximum efficiency at 50 to 75 percent full load.

thumb_up_alt 0 like thumb_down_alt 0 dislike

Related questions

Answer : D.C. generators are normally designed for maximum efficiency around full-load.

Description : State why nuclear power plants are used as base load plants and diesel power plants as a peak load plant. 

Answer : 1. Because of following points Nuclear power plant used as base load power plant:-  1. Nuclear power plants is very economical for producing bulk amount of electric power 2. Nuclear power plant is reliable ... . The plants can be put on load easily. 4. Diesel engines take less time to make OFF.

Description : What is base load and peak load power plants?

Description : For a transformer, operating at constant load current, maximum efficiency will occur at?

Answer : For a transformer, operating at constant load current, maximum efficiency will occur at unity power factor.

Answer : An ideal transformer will have maximum efficiency at a load such that copper loss equal to iron loss.

Answer : The efficiency of a properly designed synchronous motor will usually fall in range 85 to 95%.

Description : Compare base load plant with peak load plant. 

Answer : Sr.No. Points Base load plant Peak load plant  1 Definition The power plant which supplies base load of load curve is known as base load plant The power ... power station   Small capacity storage hydro, pumped storage hydro, gas, diesel power station. 

Answer : The condition for maximum efficiency for a D.C. generator is variable losses equal to constant losses.

Description : Compare base load plant with peak load plant on any two points.

Answer : Points Base load plant Peak load plant Definition The power plant which supplies base load of load curve is known as base load plant  The power plant which supplies ... ,thermal,nuclear power station Small capacity storage hydro,pumped storage hydro,gas,diesel power station.

Description : An SSB transmitter produces a peak-to-peak voltage of 200 V across a 100 Ω antenna load. What is the Peak Envelope Power? A) 49.98 W B) 79.98 W C) 99.96 W D) 199.93 W

Answer : An SSB transmitter produces a peak-to-peak voltage of 200 V across a 100 Ω antenna load. What is the Peak Envelope Power? A) 49.98 W B) 79.98 W C) 99.96 W D) 199.93 W

Answer : Transformer efficiency is maximum when copper losses are equal to iron losses.

Description : A transformer operates 24 hours day at full -load. It's full -load efficiency is :  (A) equal all day efficiency (B) more than all -day efficiency (C) less than all -day efficiency (D) equal to maximum efficiency

Answer : A transformer operates 24 hours day at full -load. It's full -load efficiency is : equal all day efficiency 

Description : The efficiency of two identical transformers under load conditions can be determined by?

Answer : The efficiency of two identical transformers under load conditions can be determined by back-to-back test.

Description : A single core cable is designed to work for a single phase system with a peak voltage of 220 kV. The maximum permissible stress in the dielectric is not to exceed 20 kV/mm. For economical size, the overall core diameter of the cable is (A) 28.2 mm (B) 26.4 mm (C) 24.4 mm (D) 22.0 mm

Answer : A single core cable is designed to work for a single phase system with a peak voltage of 220 kV. The maximum permissible stress in the dielectric is not to exceed 20 kV/mm. For economical size, the overall core diameter of the cable is 22.0 mm

Description : The maximum constant load torque under which a synchronous motor will pull into synchronism at rated rotor supply voltage and frequency is known as?

Answer : The maximum constant load torque under which a synchronous motor will pull into synchronism at rated rotor supply voltage and frequency is known as pull-in torque.

Description : The maximum load that a power transformer can carry is limited by its?

Answer : The maximum load that a power transformer can carry is limited by its voltage ratio.

Description : The synchronous motor will develop maximum power when the load angle is?

Answer : The synchronous motor will develop maximum power when the load angle is 900.

Description : Classify the hydro-electric plants according to the head and load basis.  

Answer : Classification the hydro-electric plants According to availability of Head of Water:  1. Very high head power plant 2. High head power plant 3. Medium head power plant 4. Low head power plant  ... -electric plants According to Load basis:   1. Base load power plant 2. Peak load power plant

Answer : Large capacity generators are invariably hydrogen cooled.

Answer : D.C. generators are installed near the load centres to reduce line losses.

Answer : Most efficient plants are normally used as base load plants.

Description : Identify the increasing order of voltage regulation of the following dc generators a same load :  (A) differential compound, shunt and under compound  (B) shunt, differential compound and ... C) under compound, shunt and differential compound  (D) shunt, under compound and differential compound

Answer : Identify the increasing order of voltage regulation of the following dc generators a same load : under compound, shunt and differential compound 

Description : Two synchronous generators operating in parallel supply a common load of 2.5 MW. The frequency-power characteristics have a common slope of 1 MW/Hz and the no-load frequencies of the generators are 51.5 Hz and 51.0 Hz, ... system frequency is (A) 50 Hz (B) 51 Hz (C) 51.25 Hz (D) 51.5 Hz

Answer : Two synchronous generators operating in parallel supply a common load of 2.5 MW. The frequency-power characteristics have a common slope of 1 MW/Hz and the no-load frequencies of the generators are 51.5 Hz and 51.0 Hz, respectively. Then the system frequency is 50 Hz

Description : With a neat diagram explain medium head hydro-electric power plants. 

Answer : Diagram of medium head hydro-electric power plants:  Explanation:- If head of water is between 30 and 100 m, the plant is called a medium-head plant. Potential energy of ... Francis turbines are normally used. Alternator required in these plants is of low speed and large in diameter. 

Description : The problematic pollutants in emission of coal based generating plants __________.  (A) SO₂ (B) NOx (C) CO (D) All of the above

Answer : The problematic pollutants in emission of coal based generating plants __________.  (A) SO₂ (B) NOx (C) CO (D) All of the above

Description : In hydroelectric power plants  (1) both operating and initial cost are high (2) both operating and initial cost are low (3) operating cost is low and initial cost is high (4) operating cost is high and initial cost is low

Answer : In hydroelectric power plants operating cost is low and initial cost is high

Description : What is the purpose of the turbines in coal fired power plants?

Answer : The load factor of domestic load is usually 10 to 15%.

Answer : Air blast circuit breakers for 400 kV power system are designed to operate in 50 millisecond.

Answer : 1. Connected Load: It is the sum of load of all equipment's connected to supply system which are in use or not in use of each consumer. OR   The sum of connected load of all consumers ... is the maximum load which a consumer uses at a particular time period out of his total connected load. 

Description : The overall efficiency of Thermal Power Plant is equal to _______________ .  (A) Regenerative Cycle Efficiency (B) Renkine Cycle Efficiency (C) Carnot cycle efficiency (D) None of the above

Answer : The overall efficiency of Thermal Power Plant is equal to Regenerative Cycle Efficiency. 

Description : The rankine cycle efficiency of steam power plant is  (1) 60-80% (3) 30-45% (2) 45-80% (4) 20-30%

Answer : The rankine cycle efficiency of steam power plant is 30-45%

Description : Explain the lighting scheme to be designed for each of the following: i) Special ward in hospitals ii) Dentist’s Cabin 

Answer : i) Special ward in hospital: For the patients in the wards, lighting should create a cozy and pleasant atmosphere. Lighting in the wards should be planned in such a way that it meets the specific ... we use such as cements and bonding agents that we use to restore your teeth back to health.

Description : What would happen if a power transformer designed for operation on 50 Hz (frequency) were connected to a 500 Hz (frequency) source of the same voltage:  (A) Eddy Current and Hysteresis losses will be ... Current will be too much high  (C) Transformer may start to smoke and burn  (D) No effect

Answer : What would happen if a power transformer designed for operation on 50 Hz (frequency) were connected to a 500 Hz (frequency) source of the same voltage:  (A) Eddy Current and Hysteresis losses will be ... will be too much high  (C) Transformer may start to smoke and burn  (D) No effect

Answer : Overhead system can be designed for operation up to 400 kV.

Description : Why are generators rated in kVA not in kW ?

Answer : Because It's rating of generator kva is apparent power. Kw is active power which we use. And one is kvar reactive power.

Description : Two synchronous generators G1, G2 are operating in parallel and are equally sharing KVAR (Lag) component of load. To shift part of KVAR from G2 to G1, while keeping terminal voltage fixed, the following action must be done

Answer : Two synchronous generators G1, G2 are operating in parallel and are equally sharing KVAR (Lag) component of load. To shift part of KVAR from G2 to G1, while keeping terminal voltage fixed, the following action must be done Raise If1 and lower If2

Answer : If  equalising bar is connected to the 2 DC generators  the current will be equal in 2 generators irrespective of parallel connection so that we connect equaliser bar

Answer : Compensating windings are used in D.C. generators to neutralise the cross-magnetising effect of the armature reaction.

Answer : D.C. generators are connected to the busbars or disconnected from them only under the floating condition to avoid sudden loading of the primemover, to avoid mechanicaljerk to the shaft, to avoid burning of switch contacts.

Answer : In D.C. generators the pole shoes are fastened to the pole core by counter sunk screws.

Description : In DC generators lamination core are generally made of?

Answer : In DC generators lamination core are generally made of silicon steel.

Answer : For the parallel operation of two or more D.C. compound generators, we should ensure that series fields of all generators should be either on positive side or negative side of the armature.

Answer : In a power plant if the maximum demand on the plant is equal to the plant capacity, then plant reserve capacity will be zero.

Answer : Maximum demand on a power plant is the greatest of all "short time interval averaged" demand during a period.

Answer : Power plant having maximum demand more than the installed rated capacity will have utilisation factor more than unity.

Description : What is the maximum value of power factor?

Answer : 1 is the maximum value of power factor.

Description : A circuit breaker is designed to protect an electrical circuit from damage caused by :  (A) Over load (B) Short circuit (C) Over current (D) All of the above

Answer : A circuit breaker is designed to protect an electrical circuit from damage caused by :  (A) Over load (B) Short circuit (C) Over current (D) All of the above

Answer : An efficient and a well designed protective relaying should have good selectivity and reliability, economy and simplicity, high speed and selectivity.

Answer : Relays can be designed to respond to changes in resistance, reactance or impedance voltage and current, light intensity, temperature.