1 Answer

A low utilization factor for a plant indicates that plant is used for stand by purpose.

Like 0 like Dislike 0 dislike

Related questions

Answer : High load factor indicates total plant capacity is utilised for most of the time.

Answer : The primary reason for low power factor is supply system is due to installation of induction motors.

Answer : Power plant having maximum demand more than the installed rated capacity will have utilisation factor more than unity.

Answer : Peak load plant can never have 100 percent load factor.

Answer : In a low power factor wattmeter the pressure coil is connected to the load side of the current coil.

Description : At which time power factor of the induction motor is low?

Answer : The power factor of the inducction motor is low at the time of starting as compare to while the induction motor is running.

Answer : A load curve indicates average kWh (kW) energy consumption during the period.

Description : In an AC. circuit, a low value of kVAR compared with kW indicates?

Answer : In an AC. circuit, a low value of kVAR compared with kW indicates high power factor.

Description : What are the criteria for selection of site for hydroelectric power plant?

Answer : Following Factors to be kept while site selecting for Hydro power plant:  1. It should be located where high rain fall occurs. 2. A large catchments area must be available to store water. 3. It ... 12. Cost of land should be less. 13. Skilled and unskilled man power should be available nearby.

Answer : For a consumer the most economical power factor is generally 0.95 lagging .

Answer : For high value of diversity factor, a power station of given installed capacity will be in a position to supply more number of consumers.

Description : Explain the function of different parts of a typical nuclear power plant with neat sketch. 

Answer : Functions of each part of Nuclear power plant:-  1) Nuclear Reactor: In nuclear reactor the fuel rod of U235 is placed through which tremendous amount of heat energy is ... is mechanically coupled with steam turbine. 8) Alternator: It converts mechanical energy into electrical energy.

Description : With a neat diagram explain pumped storage hydro power plant. 

Answer : Diagram of pumped storage hydro power plant: Explanation: In this power plant, generator is so designed that it Converts mechanical power into electrical power and also works as a ... helps in reducing a reserve capacity of PP as it provides additional power during peak load period. 

Description : Draw a layout of a thermo-chemical based power plant. 

Answer : Layout of a thermo-chemical based power plant:  In this process dry biomass fuels converted to produce gas ,liquid fuels or oil by thermo chemical conversion Thermo-Chemical conversion are of following ways:- 1. Direct combustion 2. Gasification 3. Pyrolysis

Description : With a neat diagram explain solar photovoltaic power plant. 

Answer : Diagram of solar photovoltaic power plant :  Explanation:  Solar power plant consists of following components:  1. Photovoltaic cell panel: Its function is to convert sunrays directly into DC ... .  5. Step-up transformer: It step-up input voltage to utilization voltage e.g. 230V

Description : Draw and explain fixed dome type biogas plant. 

Answer : Diagram of fixed dome type biogas plant: Explanation of layout of biogas plant by the method of fermentation conversion  1. Foundation : Biomass plant consists of pit excavated to desire ... the slurry from the top of the dome with the help of stirrer which is at digester chamber.

Description : Compare base load plant with peak load plant. 

Answer : Sr.No. Points Base load plant Peak load plant  1 Definition The power plant which supplies base load of load curve is known as base load plant The power ... power station   Small capacity storage hydro, pumped storage hydro, gas, diesel power station. 

Answer : Because of following advantages concentrating type collector are used in solar power plant: -  1. Temperature: Temperature obtained is high because absorber area is less and collector/reflector area ... results: As tracking system is used better results are obtain than flat type collector.

Description : List the types of turbine used in hydro power plant.  

Answer : Following types of turbine used in hydro power plant:  1.Pelton wheel 2.Francis Turbine 3.Kaplan Turbine 4.Propeller Turbine 

Description : The overall efficiency of Thermal Power Plant is equal to _______________ .  (A) Regenerative Cycle Efficiency (B) Renkine Cycle Efficiency (C) Carnot cycle efficiency (D) None of the above

Answer : The overall efficiency of Thermal Power Plant is equal to Regenerative Cycle Efficiency. 

Description : In a thermal power plant, ash is collected in

Answer : In a thermal power plant, ash is collected in hoppers or bunkers

Description : The rankine cycle efficiency of steam power plant is  (1) 60-80% (3) 30-45% (2) 45-80% (4) 20-30%

Answer : The rankine cycle efficiency of steam power plant is 30-45%

Answer : Nuclear power plant is invariably used as base load plant.

Answer : In a power plant if the maximum demand on the plant is equal to the plant capacity, then plant reserve capacity will be zero.

Answer : Hydroelectric power plant is expected to have the longest life.

Answer : Maximum demand on a power plant is the greatest of all "short time interval averaged" demand during a period.

Answer : Annual operating expenditure of a power plant consists of fixed charges, semi-fixed charges, running charges.

Description : What is the largest power plant in the world?

Answer : japam

Description : How many watts does a power plant produce?

Description : What is the most common type of power plant?

Answer : Hydroelectric  power  plant.

Description : How much electricity is produced by a power plant?

Description : In order to have a lower cost of electrical energy generation the load factor  (1) and the diversity factor should be low (2) should be low but the diversity factor should be high (3) should be high but the diversity factor should be low (4) and the diversity factor both should be high

Answer : In order to have a lower cost of electrical energy generation the load factor and the diversity factor both should be high

Answer : An induction motor has relatively high power factor at near full load.

Answer : In a distribution system, in order to improve power factor, the synchronous capacitors are installed at the receiving end.

Answer : In an interconnected system, the diversity factor of the whole system increases.

Description : Diversity factor has direct effect on the?

Answer : Diversity factor has direct effect on the fixed cost of unit generated.

Answer : In two part tariff, variation in load factor will affect operating or running charges.

Answer : Demand factor is defined as maximum demand/connected load.

Answer : The load factor of domestic load is usually 10 to 15%.

Answer : Load factor of a power station is generally less than unity.

Answer : Load factor of a power station is defined as average load/maximum demand.

Description : Can a synchronous condenser improve power factor?

Answer : Yes, synchronous condenser can improve power factor.

Description : What is the maximum value of power factor?

Answer : 1 is the maximum value of power factor.

Description : Name two methods for measurement of low, medium and high resistance. Give one advantage and one limitation of V- I method.

Answer : Methods for measurement of low resistance:  1. Ammeter voltmeter method  2. Kelvin's bridge method  3. Ohm meter method  4. Potentiometer method  5. Digital/analog multi-meter ... must be infinity for perfectly accurate measurement which is not possible.  2. Connection errors.

Description : State the range for low and medium resistance.

Answer : Low resistances: less than 1 ohm.  Medium resistances: 1 ohm to 0.1 Mega ohm. 

Description : Which of the following is the least expensive protection for over current in low voltage system?  (A) Rewireable fuse (B) Isolator (C) Oil Circuit breaker (D) Air break circuit breaker

Answer : Which of the following is the least expensive protection for over current in low voltage system?  (A) Rewireable fuse (B) Isolator (C) Oil Circuit breaker (D) Air break circuit breaker

Answer : Turbine used for low head is Kaplan turbine.

Answer : MOSFET have high current losses due to High on state resistance. Hence MOSFET is used for low power applications.

Description : State the effects of low power factor on efficiency and voltage regulation of short transmission lines. 

Answer : i) Effect of Low power factor on efficiency:- When power factor of load reduces current drawn by transmission line increases so copper losses in transmission line increases, hence transmission ... increases, so voltage drop in transmission line increases so regulation increases. (Become Poor) 

← Prev Question Next Question →
Ask a Question
Choose topic