1 Answer

The load factor of domestic load is usually 10 to 15%.

thumb_up_alt 0 like thumb_down_alt 0 dislike
← Prev Question Next Question →

Related questions

Description :

In order to have a lower cost of electrical energy generation the load factor  (1) and the diversity factor should be low (2) should be low but the diversity factor should be high (3) should be high but the diversity factor should be low (4) and the diversity factor both should be high

Answer :

In order to have a lower cost of electrical energy generation the load factor and the diversity factor both should be high

thumb_up_alt 0 like thumb_down_alt 0 dislike
98 views 1 answer
Description :

Answer :

Peak load plant can never have 100 percent load factor.

thumb_up_alt 0 like thumb_down_alt 0 dislike
58 views 1 answer
Description :

Answer :

In two part tariff, variation in load factor will affect operating or running charges.

thumb_up_alt 0 like thumb_down_alt 0 dislike
63 views 1 answer
Description :

Answer :

High load factor indicates total plant capacity is utilised for most of the time.

thumb_up_alt 0 like thumb_down_alt 0 dislike
84 views 1 answer
Description :

Answer :

Load factor of a power station is generally less than unity.

thumb_up_alt 0 like thumb_down_alt 0 dislike
66 views 1 answer
Description :

Answer :

Load factor of a power station is defined as average load/maximum demand.

thumb_up_alt 0 like thumb_down_alt 0 dislike
145 views 1 answer
Description :

Load factor is the  (1) Ratio of maximum load on the station to sum of consumer's maximum load.  (2) Ratio of average demand to maximum demand.  (3) Factor used for increasing load.  (4) Reciprocal of (1).

Answer :

Load factor is the Ratio of average demand to maximum demand. 

thumb_up_alt 0 like thumb_down_alt 0 dislike
74 views 1 answer
Description :

A transformer has negative voltage regulation when its load power factor is   (1) Zero (2) Unity (3) Leading (4) Lagging

Answer :

Leading

thumb_up_alt 0 like thumb_down_alt 0 dislike
2.0k views 2 answers
Description :

The load duration curve for unity load factor will be of  (1) Rectangular shape (2) Triangular shape (3) L -shape (4) I -shape

Answer :

The load duration curve for unity load factor will be of Rectangular shape

thumb_up_alt 0 like thumb_down_alt 0 dislike
273 views 1 answer
Description :

Power station having Load factor = 70%, capacity factor = 50%, used factor = 60%, maximum demand = 20MW then annual energy production is  (1) 122.8 GWh (2) 198.55 GWh (3) 128.2 GWh (4) 188.82 GWh

Answer :

Power station having Load factor = 70%, capacity factor = 50%, used factor = 60%, maximum demand = 20MW then annual energy production is 122.8 GWh

thumb_up_alt 0 like thumb_down_alt 0 dislike
97 views 1 answer
Description :

In a synchronous generator delivering lagging power factor load  (1) the excitation emf leads terminal voltage by the power angle (2) the excitation emf lags terminal voltage by the power angle (3) excitation emf leads the terminal voltage by the power factor angle (4) excitation emf lags the terminal voltage by the power factor angle

Answer :

In a synchronous generator delivering lagging power factor load the excitation emf leads terminal voltage by the power angle

thumb_up_alt 0 like thumb_down_alt 0 dislike
235 views 1 answer
Description :

Answer :

The power factor of a single phase load can be calculated if the instruments available are three ammeters or three voltmeters.

thumb_up_alt 0 like thumb_down_alt 0 dislike
231 views 2 answers
Description :

Minimum voltage regulation occurs when the power factor of the load is?

Answer :

Minimum voltage regulation occurs when the power factor of the load is leading.

thumb_up_alt 0 like thumb_down_alt 0 dislike
149 views 1 answer
Description :

If the load of the normally excited synchronous motor is increased the power factor will?

Answer :

If the load of the normally excited synchronous motor is increased the power factor will become lagging.

thumb_up_alt 0 like thumb_down_alt 0 dislike
118 views 1 answer
Description :

The synchronous motor which works on leading power factor and does not drive any mechanical load is called?

Answer :

The synchronous motor which works on leading power factor and does not drive any mechanical load is called synchronous condenser.

thumb_up_alt 0 like thumb_down_alt 0 dislike
86 views 1 answer
Description :

Answer :

Most common form of A.C. meters met with in every day domestic and industrial installations are induction type single phase energy meters.

thumb_up_alt 0 like thumb_down_alt 0 dislike
159 views 1 answer
Description :

Answer :

The wattage of motor for driving domestic sewing machine will be around 100 to 150 W.

thumb_up_alt 0 like thumb_down_alt 0 dislike
83 views 1 answer
Description :

Answer :

Generators for peak load plants are usually designed for maximum efficiency at 50 to 75 percent full load.

thumb_up_alt 0 like thumb_down_alt 0 dislike
93 views 1 answer
Description :

The following formula is correct:  (A) Load factor=Average load for a period/ Peak load for the same period  (B) Load factor=Average load for a period x Peak load for the same period  (C) Load factor=Average load for a period + Peak load for the same period  (D) All of the above

Answer :

The following formula is correct: (A) Load factor=Average load for a period/ Peak load for the same period (B) Load factor=Average load for a period x Peak load for the same period (C) Load factor=Average load for a period + Peak load for the same period (D) All of the above

thumb_up_alt 0 like thumb_down_alt 0 dislike
59 views 1 answer
Description :

Power factor of an inductive circuit is usually improved by connecting capacitor to it in?

Answer :

Power factor of an inductive circuit is usually improved by connecting capacitor to it in parallel.

thumb_up_alt 0 like thumb_down_alt 0 dislike
189 views 1 answer
Description :

Answer :

The power factor of a single-phase induction motor is usually lagging.

thumb_up_alt 0 like thumb_down_alt 0 dislike
131 views 1 answer
Description :

Answer :

An induction motor has relatively high power factor at near full load.

thumb_up_alt 0 like thumb_down_alt 0 dislike
69 views 1 answer
Description :

Answer :

In a distribution system, in order to improve power factor, the synchronous capacitors are installed at the receiving end.

thumb_up_alt 0 like thumb_down_alt 0 dislike
123 views 1 answer
Description :

Answer :

For a consumer the most economical power factor is generally 0.95 lagging .

thumb_up_alt 0 like thumb_down_alt 0 dislike
154 views 1 answer
Description :

Answer :

In an interconnected system, the diversity factor of the whole system increases.

thumb_up_alt 0 like thumb_down_alt 0 dislike
104 views 1 answer
Description :

Answer :

The primary reason for low power factor is supply system is due to installation of induction motors.

thumb_up_alt 0 like thumb_down_alt 0 dislike
98 views 1 answer
Description :

Answer :

A low utilization factor for a plant indicates that plant is used for stand by purpose.

thumb_up_alt 0 like thumb_down_alt 0 dislike
158 views 1 answer
Description :

Answer :

For high value of diversity factor, a power station of given installed capacity will be in a position to supply more number of consumers.

thumb_up_alt 0 like thumb_down_alt 0 dislike
124 views 1 answer
Description :

Answer :

Power plant having maximum demand more than the installed rated capacity will have utilisation factor more than unity.

thumb_up_alt 0 like thumb_down_alt 0 dislike
83 views 1 answer
Description :

Answer :

Diversity factor has direct effect on the fixed cost of unit generated.

thumb_up_alt 0 like thumb_down_alt 0 dislike
139 views 1 answer
Description :

Answer :

Demand factor is defined as maximum demand/connected load.

thumb_up_alt 0 like thumb_down_alt 0 dislike
58 views 1 answer
Description :

Can a synchronous condenser improve power factor?

Answer :

Yes, synchronous condenser can improve power factor.

thumb_up_alt 0 like thumb_down_alt 0 dislike
74 views 1 answer
Description :

What is the maximum value of power factor?

Answer :

1 is the maximum value of power factor.

thumb_up_alt 0 like thumb_down_alt 0 dislike
91 views 1 answer
Description :

Compare base load plant with peak load plant. 

Answer :

Sr.No. Points Base load plant Peak load plant  1 Definition The power plant which supplies base load of load curve is known as base load plant The power ... power station   Small capacity storage hydro, pumped storage hydro, gas, diesel power station. 

thumb_up_alt 0 like thumb_down_alt 0 dislike
100 views 1 answer
Description :

Answer :

1. Connected Load: It is the sum of load of all equipment's connected to supply system which are in use or not in use of each consumer. OR   The sum of connected load of all consumers ... is the maximum load which a consumer uses at a particular time period out of his total connected load. 

thumb_up_alt 0 like thumb_down_alt 0 dislike
75 views 1 answer
Description :

Answer :

Nuclear power plant is invariably used as base load plant.

thumb_up_alt 0 like thumb_down_alt 0 dislike
87 views 1 answer
Description :

Answer :

In a load curve the highest point represents peak demand.

thumb_up_alt 0 like thumb_down_alt 0 dislike
89 views 1 answer
Description :

Answer :

Generating capacity connected to the bus bars and ready to take load when switched on is known as spinning reserve.

thumb_up_alt 0 like thumb_down_alt 0 dislike
122 views 1 answer
Description :

Answer :

The increased load during summer months is due to increased use of fans and air conditioners.

thumb_up_alt 0 like thumb_down_alt 0 dislike
44 views 1 answer
Description :

Answer :

Load curve is useful in deciding the operating schedule of generating units, sizes of generating units, total installed capacity of the plant.

thumb_up_alt 0 like thumb_down_alt 0 dislike
104 views 1 answer
Description :

Answer :

The area under a load curve gives energy consumed.

thumb_up_alt 0 like thumb_down_alt 0 dislike
76 views 1 answer
Description :

Answer :

A load curve indicates average kWh (kW) energy consumption during the period.

thumb_up_alt 0 like thumb_down_alt 0 dislike
66 views 1 answer
Description :

Answer :

The standard full-load power factor ratings for synchronous motors are unity or 0.8 leading.

thumb_up_alt 0 like thumb_down_alt 0 dislike
74 views 1 answer
Description :

State the effects of low power factor on efficiency and voltage regulation of short transmission lines. 

Answer :

i) Effect of Low power factor on efficiency:- When power factor of load reduces current drawn by transmission line increases so copper losses in transmission line increases, hence transmission ... increases, so voltage drop in transmission line increases so regulation increases. (Become Poor) 

thumb_up_alt 0 like thumb_down_alt 0 dislike
113 views 1 answer
Description :

Briefly explain how the power factor of an inductive circuit can be improved.

Answer :

As we know that power factor should be corrected to ensure that the current supplied is cost friendly. Meaning the power factor should be around one but not greater than one(0.8-0.9) in a ... an inductive circuit due to the inductive reactance which oppose the change of current in the ac circuit. 

thumb_up_alt 0 like thumb_down_alt 0 dislike
112 views 1 answer
Description :

What is the value of capacitance required to improve power factor from 0.7 to 0.9. Given that: Real power = 50 W Vrms of the source = 120 Frequency = 50 Hz   #powerfactor

thumb_up_alt 0 like thumb_down_alt 0 dislike
190 views 0 answers
Description :

Define leakage factor.

Answer :

It is the ratio of total flux to leakage flux.

thumb_up_alt 0 like thumb_down_alt 0 dislike
47 views 1 answer
Description :

Define PIV, TUF, ripple factor, efficiency of rectifier.

Answer :

Peak Inverse Voltage (PIV): The maximum value of reverse voltage (for the diode in a rectifier) occurring at the peak of the negative cycle of the input cycle is called Peak Inverse Voltage. ... dc power delivered to the load to the ac input power from the secondary winding of the transformer. 

thumb_up_alt 0 like thumb_down_alt 0 dislike
321 views 1 answer
Description :

working of distortion factor meter with block diagram

Answer :

Working : Initially the switch S is kept at position 1.The attenuator gets excluded and the bridge T network is adjusted for full suppression of fundamental frequency and hence we get ... is obtained on the meter.Thus the total rms distortion is indicated by the reading of attenuator. 

thumb_up_alt 0 like thumb_down_alt 0 dislike
652 views 1 answer
Description :

Why capacitors are used to improve power factor?

Answer :

 Capacitors generate reactive power instead of that drawn from source which is required by inductive loads.so it reduce the reactive current which is drawn from source to be drawn from capacitor.This control in Electric bills cost.

thumb_up_alt 1 like thumb_down_alt 0 dislike
136 views 3 answers
editAsk a Question
...