search
person

1 Answer

A fuse is connected in series with circuit.

thumb_up_alt 0 like thumb_down_alt 0 dislike

Related questions

Description : A fuse wire should have :  (A) Low specific resistance and high melting point (B) Low specific resistance and low melting point (C) High specific resistance and high melting point (D) High specific resistance and low melting point

Answer : A fuse wire should have : High specific resistance and low melting point

Description : ln HRC fuse the time between cut-off and final current zero is called

Answer : ln HRC fuse the time between cut-off and final current zero is called the arcing time

Answer : A fuse in a motor circuit provides protection against short-circuit and overload.

Answer : The fuse blows off by melting.

Answer : The fuse rating is expressed in terms of current.

Answer : H.R.C. fuse, as compared to a rewirable fuse, has no ageing effect, high speed of operation, high rupturing capacity.

Answer : The material used for fuse must have low melting point and high specific resistance.

Answer : The main function of a fuse is to prevent excessive currents.

Description : State any two advantages of MCB over Fuse. State the standard specifications of MCB available in the market.  

Answer : Following advantages of MCB over Fuse: 1. No need of replacement of fuse wire. 2. Manually restore of supply is simple. 3. Fault understanding by visual inspection 4. More safe than fuse The standard specifications of ... 6A, 10A,16A,20A, 25A, 30A, 32A, 40A, 50A, 60A and 63A 6. 250V and 450 v

Description : State the material used for making (1) Magnetic Core (2) Fuse element  

Answer : The material used for making of:  (1) Magnetic Core : Iron, cobalt, Nickel, CRGO, HRGO , silicon steel  (2) Fuse Element: Tin- lead wire, Tinned copper wire 

Description : Write applications of each of the following:(i) Fuse (ii) MCB (iii) MCCB.

Answer : i) Applications of fuse:  * Used in domestic installations to provide short circuit protection.  * Used in commercial / Industrial installations to provide overload and short circuit protection.  * Used in ...  * Rectifiers panels,  * U.P.S, Electronic equipment,  * Motors,  * Furnaces

Description : Give the function of fuse and switch.

Answer : Functions of fuse:  * To break the circuit under fault condition.  * To provide overcurrent protection to the circuit.  * To provide short circuit protection to the circuit.  * To provide ...  * To make the electric circuit manually.  * To break the electric circuit manually.

Description : What is a fuse ?

Answer :  A Fuse is a protective device which prevent overloading of current in a circuit.

Description : what is HRC fuse?

Answer : HRC (High Rupturing Capacity) fuse HRC fuse is High Rupturing Capacity fuse. At the time of fault it disconnect the circuit very fast. Filling powder is silica sand. No flashover ... speed response Reliable No maintenance CheaperDisadvantages:- We have to replace it manually after each operation.

Answer : 1. Connected Load: It is the sum of load of all equipment's connected to supply system which are in use or not in use of each consumer. OR   The sum of connected load of all consumers ... is the maximum load which a consumer uses at a particular time period out of his total connected load. 

Description : Define the terms: i) Tariff ii) Fuel surcharge iii) Electricity Duty iv) Connected load

Answer : i) Tariff: The rate at which a consumer is charged for the consumption of electricity is called as tariff. OR The amount of money framed by the supplier for the supply of electrical energy ... is the total wattage of all appliances which are used by the consumer on his sanctioned connection. 

Description : Define the following terms related to tariff: (i) Connected load (ii) Unit consumed (iii) Fixed charges (iv) Electricity Tax 

Answer : (i) Connected load  It is the sum of the power ratings (Watts or kW or MW) of all devices and machines existing (installed) in the premises of consumer. It is used to decide the ... a percentage of the total electricity bill which includes all amounts that go to the electricity supply agency. 

Description : Define each of following terms: i) Connected load ii) Spinning reserve. 

Answer : i) Connected Load :- It is the sum of load of all equipment connected to supply system which are in use or not in use of each consumer. ii) Spinning Reserve:- It is reserved generating capacity in operation and connected to bus bar and ready to take a load.

Description : A balanced Delta connected load supplied with 440 V 50 Hz three phase AC supply has R=10 Ohm and L=0.6 mH in is each arm. Calculate line and phase current, active power.

Description : Draw the phasor diagram for Star connected balanced system.

Description : Draw the Delta connected three phase system showing all the voltages and currents. Write the power equation.

Description :  A connected graph has ‘5’ number of branches and ‘4’ number of nodes. It's rank is A) 1 B) 2 C) 3 D) 4 

Answer :  A connected graph has ‘5’ number of branches and ‘4’ number of nodes. It's rank is 3 

Description : In an R-C phase shift oscillator, the minimum no. of R-C networks to be connected in cascade will be -

Answer : In an R-C phase shift oscillator, the minimum no. of R-C networks to be connected in cascade will be 3

Description : Two 100W, 200V lamps are connected in series across a 200V supply. The total power consumed by each lamp will be in Watts

Answer : 4800

Description : Three identical resistors connected in star consume 5000 W. If the resistors are connected in delta across the same supply, the power consumed will be

Answer : Three identical resistors connected in star consume 5000 W. If the resistors are connected in delta across the same supply, the power consumed will be 15000 W

Description : A four -quadrant operation requires two full converters connected in  (1) Series (3) Back to back (2) Parallel (4) Series Cascade

Answer : A four-quadrant operation requires two full converters connected in Parallel 

Description : Consider a circuit with three parallel branches connected across a DC supply. What is the ratio of the branch currents I1 : I2 : I3 if the branch resistances are in the ratio of 2 : 3 : 4 respectively? A) 2 : 3 : 4 B) 6 : 4 : 3 C) 4 : 3 : 2 D) None of these

Answer : Consider a circuit with three parallel branches connected across a DC supply. What is the ratio of the branch currents I1 : I2 : I3 if the branch resistances are in the ratio of 2 : 3 : 4 respectively? A) 2 : 3 : 4 B) 6 : 4 : 3 C) 4 : 3 : 2 D) None of these

Description : When three resistors with unequal values are connected in parallel, _______ A) The current across the resistors is the same  B) The voltage drop across the resistors is the same C) The voltage drops across the resistors is proportional to the resistance of each resistor D) None of these

Answer : When three resistors with unequal values are connected in parallel, The voltage drop across the resistors is the same

Description : What is the total resistance if 5 resistors of 20 Ω each are connected in series? A) 100 Ω B) 4 Ω C) 20 Ω D) None of these

Answer : What is the total resistance if 5 resistors of 20 Ω each are connected in series? A) 100 Ω B) 4 Ω C) 20 Ω D) None of these

Description : The sequence components of current of a single-phase load connected to a 3-phase system are (A) equal positive and negative sequence components (B) equal positive, negative and zero sequence components (C) vector sum of sequence currents is zero (D) algebraic sum of sequence currents is zero

Answer : The sequence components of current of a single-phase load connected to a 3-phase system are equal positive, negative and zero sequence components

Description : If non-linear loads are connected to the power system, then (A) displacement power factor is same as the total power factor (B) displacement power factor is not equal to the total power ... factor is due to harmonic currents (D) total power factor is due to fundamental component of current

Answer : If non-linear loads are connected to the power system, then displacement power factor is not equal to the total power factor

Description :  With three resistances connected in parallel, if each dissipates 20 W the total power supplied by the voltage source equals?

Answer : Power is the only thing which is additive in both connection whether it is parallel or series connection so total power consumed will addition of all individual power =20+20+20 = 60 watt

Answer : If a D.C. motor is connected across the A.C. supply it will burn due to heat produced in the field winding by eddy currents.

Description : Cells are connected in series in order to?

Answer : Cells are connected in series in order to increase voltage available.

Description : Explain Three Phase Bidirectional Delta Connected Controller.

Answer : Three Phase Bidirectional Delta Connected Controller:

Description : What is line voltage and phase voltage? Draw balanced three phase star connected system. Show all the voltages and currents.

Description : Describe the working of HRC fuse with neat diagram.

Answer : Working of HRC Fuse: Under normal conditions, the fuse element is at a temperature below its melting point. Therefore, it carries the normal current without overheating. When a fault ... powder and results in the formation of high resistance substance that helps in quenching the arc. 

Description : Explain construction and characteristics of HRC fuse.

Answer : Construction of H.R.C. Fuse: Figure shows the essential parts of a typical H.R.C. fuse. It mainly consist of a heat resisting ceramic body. Both the ends of the cermaic body consists ... particular circuit and for coordination purpose. A typical Fuse characteristic is shown in figure below. 

Description : Describe the difference between fuse and MCCB.

Answer : Sr. No Fuse MCCB 1 Fuse melts / fuses in case of excessive load. MCCB trips off in case of excessive load. 2 Fuse needs to be replaced after every ... Generally protects the load against short-circuit. Generally protects the load against different types of faults.

Description : The fuse in an electric circuit is connected in (1) series with neutral (2) parallel to live (3) parallel to neutral (4) series with live 

Answer : series with live

Description : The earth-wire of a cable is connected to (1) the outer metallic body of the appliance (2) the fuse of the appliance (3) the filament of the appliance (4) short circuitry of the appliance

Answer : the fuse of the appliance

Description : A fuse should be connected in

Answer : A fuse should be connected in series with phase conductor

Description : An IDMT relay of rating 5A, 2.2s and having a relay setting of 125% is connected to a supply circuit through a CT having a ratio of 400/5. The plug setting multiplier of IDMT relay in the event of fault current of 4000 A will be a. 5 b. 8 c. 10 d. 125

Description : A relay has a rating of 5 A, 2.2 sec IDMT and a relay setting of 125% TMS = 0.6. It is connected to a supply circuit through a C.T. 400/5 ratio. The fault current is 4000 A. The operating current of the relay is

Answer : A relay has a rating of 5 A, 2.2 sec IDMT and a relay setting of 125% TMS = 0.6. It is connected to a supply circuit through a C.T. 400/5 ratio. The fault current is 4000 A. The operating current of the relay is 6.25A

Description : A lightening arrester connected between the line and earth in a power system  (1) protects the terminal equipment against travelling surges (2) protects the transmission line against direct ... suppresses high frequency oscillations in the line (4) reflects back the travelling wave approaching it

Answer : A lightening arrester connected between the line and earth in a power system protects the terminal equipment against travelling surges

Description : To prevent mal-operation of differentially connected relay while energizing a transformer, the relay restraining coil is based with  (1) second harmonic current  (2) third harmonic current  (3) fifth harmonic current  (4) seventh harmonic current

Answer : To prevent mal-operation of differentially connected relay while energizing a transformer, the relay restraining coil is based with  second harmonic current 

Description : In double fertilization, the two male nuclei fuse with

Answer : In double fertilization, the two male nuclei fuse with – Egg cell and Definitive nucleus

Description : Babies are born with 300 bones, but by adulthood the number is reduced to 206. The reason for this is that many of the bones of children are composed of smaller component bones that are not yet fused ... for the baby to pass through the birth canal. The bones harden and fuse as the children grow.

Description : Trinitrotoluene is (1) used to melt metals (2) used to fuse two metals (3) used as an abrasive (4) used as an explosive

Answer : used as an explosive

Description : Electric fuse is an alloy of (1) tin and lead (2) zinc and lead (3) copper and iron (4) carbon and tin

Answer :  tin and lead

← Prev Question Next Question →