1 Answer

The inverse definite mean time relays are used for over current and earth fault protection of transformer against internal short-circuits.

Like 0 like Dislike 0 dislike

Related questions

Answer : The single phasing relays are used for the protection of three phase motors.

Description : IDMT relays are used to protect the transformer against :  (A) Internal short -circuits (B) Open circuits (C) External short circuits (D) Oil leakage

Answer : IDMT relays are used to protect the transformer against : External short circuits

Answer : Discrimination between main and back up protection is provided by the use of relays which are slow.

Answer : The relay with inverse time characteristic will operate within 5 to 10 sec.

Answer : Over voltage protection is recommended for hydro-electric generators, steam turbine generators, gas turbine generators.

Description : Surge absorbers are used for protection against

Answer : Surge absorbers are used for protection against low voltage high frequency oscillations

Description : To protect the power transformer (Y-Y with neutral grounded) against fault, what type of connection do the CTs have ?

Answer : To protect the power transformer (Y-Y with neutral grounded) against fault, what type of connection do the CTs have ? Δ-Δ connection

Description : A relay used for protection of motors against overload is :  (A) Impedance relay (B) Electromagnetic attraction type (C) Thermal relay (D) Buchholz's relay

Answer : A relay used for protection of motors against overload is : Thermal relay

Answer : Thermal overload relays are used to protect the motor against overcurrent due to heavy loads.

Description : With fault clearing time, the transient stability of a power system

Answer : With fault clearing time, the transient stability of a power system decreases

Answer : Impedance relays are used for phase faults on long line.

Description : If the fault current is 6000 A, the relay plug setting is 150% and the CT ratio is 400/5, the plug setting multiplier will be

Answer : If the fault current is 6000 A, the relay plug setting is 150% and the CT ratio is 400/5, the plug setting multiplier will be 10

Description : Which of the following is the least expensive protection for over current in low voltage system?  (A) Rewireable fuse (B) Isolator (C) Oil Circuit breaker (D) Air break circuit breaker

Answer : Which of the following is the least expensive protection for over current in low voltage system?  (A) Rewireable fuse (B) Isolator (C) Oil Circuit breaker (D) Air break circuit breaker

Description : If the % reactance upto the fault point is 20%, then the short circuit current will be

Answer : If the % reactance upto the fault point is 20%, then the short circuit current will be 5 times the full load current

Description : In which fault the maximum short circuit current occurs?

Answer : In three phase bolted fault the maximum short circuit occurs.

Description : A negative sequence relay is used for protection of  (1) Generator (3) Motor (2) Transformer (4) Long Transmission lines

Answer : A negative sequence relay is used for protection of Generator 

Description : Select insulating materials for following parts : (i) Insulation between heating element and base plate of electric iron. (ii) Insulation used over copper or aluminium conductor used for making coils. (iii) Transformer bushings. (iv) Insulation between transmission line and pole.

Answer : Parts Insulating Materials  Insulation between heating element and base plate of electric iron. Mica Insulation used over copper or aluminium conductor used for making coils.  ... Transformer bushings Porcelain  Insulation between transmission line and pole. Porcelain

Description : In the induction type directional over current relay, when a short-circuit occurs in the circuit (A) power flows in reverse direction (B) power flows in normal direction (C) directional power element does not operate (D) over current element is not energized

Answer : In the induction type directional over current relay, when a short-circuit occurs in the circuit power flows in reverse direction

Description : If the fault current is 2000 A, the relay setting is 50% and CT ratio is 400:5, the plug setting multiplier will be

Answer : If the fault current is 2000 A, the relay setting is 50% and CT ratio is 400:5, the plug setting multiplier will be 10 A

Description : ln HRC fuse the time between cut-off and final current zero is called

Answer : ln HRC fuse the time between cut-off and final current zero is called the arcing time

Description : For protection of rotating machines against lightning surges _______ is used.  (1) lightning arrester (2) capacitor (3) combination of lightning arrester and capacitor (4) lightning conductor and arrester

Answer : For protection of rotating machines against lightning surges combination of lightning arrester and capacitor is used. 

Answer : For the protection of power station buildings against direct strokes the requirements are interception, conduction and dissipation.

Description : Reactance relay is normally preferred for protection against

Answer : Reactance relay is normally preferred for protection against earth faults

Description : If an unsymmetrical line to ground fault occurs at the secondary terminals of a delta/star, ungrounded transformer, then  (A) zero sequence currents are present on both sides of the transformer  (B) ... side  (D) zero sequence currents are present on the primary side but not on the secondary side

Answer : If an unsymmetrical line to ground fault occurs at the secondary terminals of a delta/star, ungrounded transformer, then zero sequence currents are absent on both sides of the transformer 

Description : The operating point of a protective current transformer is near the

Answer : The operating point of a protective current transformer is near the Ankle point

Description : The inrush current of a transformer at no load is maximum if the supply voltage is switched on  (1) at peak voltage value (2) at zero voltage value (3) at half voltage value (4) at 0.866 time voltage value

Answer : At 0.866 time voltage value

Answer : To protect most of the electrical equipment handling low power, the types of relays used are thermocouple, electronic and bimetallic.

Answer : A fuse in a motor circuit provides protection against short-circuit and overload.

Answer : A thermal protection switch can protect against overload.

Description : The transit time of the current carriers through the channel of a JFET decides it's?

Answer : The transit time of the current carriers through the channel of a JFET decides it's gate characteristics.

Answer : The delay fuses are used for the protection of motors.

Answer : Protective relays are devices that detect abnormal conditions in electrical circuits by measuring constantly the electrical quantities which differ during normal and abnormal conditions.

Answer : Directional relays are based on flow of power.

Description : D.C. shunt relays are made of?

Answer : D.C. shunt relays are made of many turns of thin wire.

Answer : Overload relays are of induction, solid state, thermal, electromagnetic type.

Answer : Fault diverters are basically fast switches.

Answer : Relays can be designed to respond to changes in resistance, reactance or impedance voltage and current, light intensity, temperature.

Answer : Protection by fuses is generally not used beyond 100 A .

Answer : Reactance relay is preferred for phase fault on short transmission line.

Description : For a transformer, operating at constant load current, maximum efficiency will occur at?

Answer : For a transformer, operating at constant load current, maximum efficiency will occur at unity power factor.

Description : Explain the electrical losses of magnetic materials used for the cores of inductors and transformer.

Description : For a given matrix inverse of a matrix is

Answer : For a given matrix inverse of a matrix is https://youtu.be/gL8Q6IQjTHY

Description : Eddy current damping cannot be used for moving iron instrument because

Answer : Eddy current damping cannot be used for moving iron instrument because the presence of a permanent magnet required for such purpose would affect the deflection and hence the reading of the instrument

Description : Step-down transformer converts high voltage and low current into:  (A) How voltage and high current (B) High voltage and low current (C) Low voltage and high current (D) None of the above

Answer : Step-down transformer converts high voltage and low current into: Low voltage and high current

Answer : Overfluxing protection is recommended for generator transformer of the power plant.

Description : Which is the most common type of fault?

Answer : Single phase to ground fault is the most common type of fault.

Description : Even at no-load, a transformer draws current from the mains. Why?

Description : In a single-phase transformer, the magnetizing current is (A) in phase with the no-load current (B) in quadrature with the no-load current (C) the product of no-load current and power factor (D) in phase with the flux in the core

Answer : In a single-phase transformer, the magnetizing current is in phase with the flux in the core

Description : When secondary of a current transformer is open-circuited its iron core will be?

Answer : When secondary of a current transformer is open-circuited its iron core will be hot because of heavy iron losses taking place in it due to high flux density.

Description : The secondary of a current transformer is always short-circuited under operating conditions because it?

Answer : The secondary of a current transformer is always short-circuited under operating conditions because it avoids core saturation and high voltage induction.