1 Answer

The single phasing relays are used for the protection of three phase motors.

Like 0 like Dislike 0 dislike

Related questions

Answer : The inverse definite mean time relays are used for over current and earth fault protection of transformer against internal short-circuits.

Answer : Discrimination between main and back up protection is provided by the use of relays which are slow.

Answer : Impedance relays are used for phase faults on long line.

Description : IDMT relays are used to protect the transformer against :  (A) Internal short -circuits (B) Open circuits (C) External short circuits (D) Oil leakage

Answer : IDMT relays are used to protect the transformer against : External short circuits

Description : Surge absorbers are used for protection against

Answer : Surge absorbers are used for protection against low voltage high frequency oscillations

Description : A relay used for protection of motors against overload is :  (A) Impedance relay (B) Electromagnetic attraction type (C) Thermal relay (D) Buchholz's relay

Answer : A relay used for protection of motors against overload is : Thermal relay

Description : A negative sequence relay is used for protection of  (1) Generator (3) Motor (2) Transformer (4) Long Transmission lines

Answer : A negative sequence relay is used for protection of Generator 

Answer : To protect most of the electrical equipment handling low power, the types of relays used are thermocouple, electronic and bimetallic.

Answer : Thermal overload relays are used to protect the motor against overcurrent due to heavy loads.

Description : What are the five types of single phase motors used in the industry?

Answer : The delay fuses are used for the protection of motors.

Description : Describe different RT level computational and sequential components used to design single function processors.

Answer : RT-level combinational components:- To reduce the complexity in digital logic, combinational components are used, which are more powerful than logic gates.  Such combinational ... during a clock edge. An asynchronous inputs value effects the circuit independent of the clock.

Answer : Protective relays are devices that detect abnormal conditions in electrical circuits by measuring constantly the electrical quantities which differ during normal and abnormal conditions.

Answer : Directional relays are based on flow of power.

Description : D.C. shunt relays are made of?

Answer : D.C. shunt relays are made of many turns of thin wire.

Answer : Overload relays are of induction, solid state, thermal, electromagnetic type.

Description : For protection of rotating machines against lightning surges _______ is used.  (1) lightning arrester (2) capacitor (3) combination of lightning arrester and capacitor (4) lightning conductor and arrester

Answer : For protection of rotating machines against lightning surges combination of lightning arrester and capacitor is used. 

Description : With the help of neat diagram, describe the procedure to carry out phasing out test on a 3 phase transformer. Also state the purpose of conducting this test on 3 phase transformer.

Answer : i) This test is carried out on 3-ph transformer to identify primary & secondary winding belonging to the same phase. ii) As shown in fig above all primary & secondary phases ... of this test is to check the respective phases of primary & secondary windings in 3-ph transformer

Description : Why phasing out and polarity test is carried out on three phase transformer?

Answer : The phasing out test is carried out to identify the windings (primary and secondary) of corresponding phase of the three phase transformer. The polarity test is carried out to identify the ... identical polarity of the primary and secondary windings of each phase of the three phase transformer.

Answer : For the protection of power station buildings against direct strokes the requirements are interception, conduction and dissipation.

Answer : Relays can be designed to respond to changes in resistance, reactance or impedance voltage and current, light intensity, temperature.

Answer : Protection by fuses is generally not used beyond 100 A .

Description : Reactance relay is normally preferred for protection against

Answer : Reactance relay is normally preferred for protection against earth faults

Answer : Overfluxing protection is recommended for generator transformer of the power plant.

Answer : Over voltage protection is recommended for hydro-electric generators, steam turbine generators, gas turbine generators.

Description : Blind spot is a point in the zones of protection where

Answer : Blind spot is a point in the zones of protection where No protection is available.

Answer : A fuse in a motor circuit provides protection against short-circuit and overload.

Answer : A thermal protection switch can protect against overload.

Description : Primary and Backup Protection

Answer : Primary and Backup Protection  B,D,G,I are the primary protection. A,C,H,J are the backup protection. About 90% of faults are clear by Primary Protection. So ... ordinated backup (primary is at various station  and backup is at control room with computer)

Description : How many types of types of relays are there?

Description : Consider the following statements. Which of these statements are correct ?  (1) Reactance relays are preferred for ground fault relaying  (2) Impedance relays are most suitable for:protecting long transmission lines  (3) Mho relays are best ... (1) and (3) (C) (2) and (4) (D) (1), (2) and (4)

Answer : Consider the following statements. Which of these statements are correct ?  (1) Reactance relays are preferred for ground fault relaying  (2) Impedance relays are most suitable for:protecting long transmission lines  (3) Mho relays are ... (1) and (3) (C) (2) and (4) (D) (1), (2) and (4)

Description :  For the protection of parallel feeders fed from one end, the relays used are: A) non-directional relays at the source-end and directional relays at the load-end B) non-directional relays at both the ... at the source-end and non-directional at the load-end D) directional relays at both the ends

Answer : For the protection of parallel feeders fed from one end, the relays used are: non-directional relays at the source-end and directional relays at the load-end

Answer : In a single bus-bar system there will be complete shut down when fault occurs on the bus itself.

Description : Explain in detail over-voltage protection.

Answer : Over-voltage protection: Over-voltage protection to the thyristor is provided using: i) R-C Snubber circuit ii) Non-linear resistor Thyrector A) Snubber Circuit: It is basically a ... returns to its high resistance state. Thyrector is normally placed across the supply terminals.

Description : Regulating-transformers are used in power systems for control of

Answer : Regulating-transformers are used in power systems for control of power flow

Description : Why is a capacitor used in a single phase motor and not in three phase motor ?

Answer : In 1-phase induction motor capacitor work is generate the auxiliary winding current than excite the main winding to rotor starts rotate. After rotor start rotating about 75% of their speed than auxiliary ... emf to start the motor.so,in 3-phase induction motor is self start induction motor.

Description : Series reactors are used to

Answer : Series reactors are used to bring down the fault level within the capacity of the switchgear

Answer : Series capacitors are used to compensate for line inductive reactance.

Description : Earthing switch is used for?  (A) Measuring of safety voltage (B) Protection of equipment from ground faults (C) Discharging residual energies (D) All of the above 

Answer : Earthing switch is used for?  (A) Measuring of safety voltage (B) Protection of equipment from ground faults (C) Discharging residual energies (D) All of the above 

Answer : A switchgear is device used for switching, controlling and protecting the electrical circuit and equipment.

Answer : The material used for fuse must have low melting point and high specific resistance.

Answer : The under voltage relay can be used for generators, busbars, transformers, motors.

Answer : Air blast circuit breaker is used for repeated duty.

Description : A single core lead sheathed cable with two dielectrics of permittivity 4 and 3, respectively, are subjected to same maximum stress. If the conductor diameter is 1.5 cm, the outer diameter of the first dielectric is (A) 1.125 cm (B) 1.5 cm (C ) 2 cm (D) 8 cm

Answer : A single core lead sheathed cable with two dielectrics of permittivity 4 and 3, respectively, are subjected to same maximum stress. If the conductor diameter is 1.5 cm, the outer diameter of the first dielectric is 2 cm 

Answer : The power factor of a single phase load can be calculated if the instruments available are three ammeters or three voltmeters.

Description : Draw single phase full wave mid-point converter for inductive load. Draw input and output waveforms for it. 

Answer : Circuit Diagram: Waveforms:

Description : State suitable single phase motor for following applications: (i) Table fan (ii) Mixers and Grinders

Answer : Application Suitable Single Phase Motor Table Fan 1) Capacitor split phase motor 2) Capacitor start capacitor run motor Mixers and Grinders 1) Universal motor 2) A.C. Series motor

Description : What is the power factor when a single phase watt meter operating on 200 V and 5 A for 5 hours makes 2016 revolutions and the meter constant in revolution is 420? A) 0.04 B) 1.04 C) 0.96 D) None of these

Answer : What is the power factor when a single phase watt meter operating on 200 V and 5 A for 5 hours makes 2016 revolutions and the meter constant in revolution is 420? A) 0.04 B) 1.04 C) 0.96 D) None of these

Description : A single core cable is designed to work for a single phase system with a peak voltage of 220 kV. The maximum permissible stress in the dielectric is not to exceed 20 kV/mm. For economical size, the overall core diameter of the cable is (A) 28.2 mm (B) 26.4 mm (C) 24.4 mm (D) 22.0 mm

Answer : A single core cable is designed to work for a single phase system with a peak voltage of 220 kV. The maximum permissible stress in the dielectric is not to exceed 20 kV/mm. For economical size, the overall core diameter of the cable is 22.0 mm

Answer : Necessary conditions required to be satisfied in order to ensure successful parallel operation of single phase transformers:  1. Only transformers having the same phase displacement between primary and secondary ... . 7. The phase sequence must be followed strictly on HV and LV side connection.