1 Answer

The arc voltage produced in A.C. circuit breaker is always in phase with the arc current.

Like 0 like Dislike 0 dislike

Related questions

Description : The arc voltage in a circuit breaker is :

Answer : The arc voltage in a circuit breaker is : in phase with the arc current

Description : The arc temperature in Oil Circuit Breaker may reach up to_______.  (A) 5,000° K (B) 8,000° K (C) 10,000° K (D) None of the above

Answer : The arc temperature in Oil Circuit Breaker may reach up to 5,000° K 

Answer : Arc in a circuit breaker is interrupted at zero current.

Description : Which of the following is used in a circuit breaker as the medium in which the arc forms? A) Insulating gas B) Insulating oil C) Vacuum D) All the above

Answer : Which of the following is used in a circuit breaker as the medium in which the arc forms? A) Insulating gas B) Insulating oil C) Vacuum D) All the above

Answer : The voltage appearing across the contacts after opening of the circuit breaker is called recovery voltage.

Description : Arc in a circuit behaves as?

Answer : Arc in a circuit behaves as a resistance decreasing with voltage rise across the arc.

Description : The number of cycles in which a high speed circuit breaker can complete its operation is  (A) 3 to 8 (B) 10 to 18 (C) 20 to 30 (D) 40 to 50

Answer : The number of cycles in which a high speed circuit breaker can complete its operation is 3 to 8

Answer : In a circuit breaker the basic problem is to transmit large power.

Answer : Ionization in circuit breaker is facilitated by high temperature, increase of mean free path, increasing field strength.

Answer : The arcing contacts in a circuit breaker are made of copper tungsten alloy.

Description : A circuit breaker is designed to protect an electrical circuit from damage caused by :  (A) Over load (B) Short circuit (C) Over current (D) All of the above

Answer : A circuit breaker is designed to protect an electrical circuit from damage caused by :  (A) Over load (B) Short circuit (C) Over current (D) All of the above

Description : The Minimum Oil Circuit Breaker (MOCB) is named because of :  (A) Reduced requirement of oil (B) Reduced requirement of air (C) All of the above (D) None of the above

Answer : The Minimum Oil Circuit Breaker (MOCB) is named because of : Reduced requirement of oil 

Description : For selecting a circuit breaker, ______ should be determined.  (A) initial current that flows on occurrence of a short circuit only (B) transient current that flows at the time of circuit interruption only (C) resonant frequency only (D) (A) and (B) 

Answer : For selecting a circuit breaker, ______ should be determined. (A) initial current that flows on occurrence of a short circuit only (B) transient current that flows at the time of circuit interruption only (C) resonant frequency only (D) (A) and (B) 

Description : ln a minimum oil circuit breaker the oil is used

Answer : ln a minimum oil circuit breaker the oil is used to act as circuit breaking medium only

Answer : Air blast circuit breaker is used for repeated duty.

Answer : Magnetic circuit breaker has instantaneous trip action.

Answer : Thermal circuit breaker has delayed trip action.

Description : what is SF6 circuit breaker?

Answer : A circuit breaker in which SF6 under pressure gas is used toextinguish the arc is calledSF6 circuit breaker. SF6 (sulphur hexafluoride) gas has excellent dielectric , arc quenching, chemical and other physical properties and has proved its ...

Description : Breaking capacity of a circuit breaker is usually expressed in terms of  (1) Ampere (2) Volts (3) MW (4) MVA

Answer : Breaking capacity of a circuit breaker is usually expressed in terms of MVA

Description : Explain working of static AC circuit breaker. 

Answer : Static AC Circuit breaker: The circuit configuration of static AC circuit breaker using SCR is shown in the figure. When switch S' is closed, the SCRs T1 and T2 are fired in positive ... non-availability of gate current. Thus the maximum time delay for breaking the circuit is one half-cycle.

Description : Explain working of AC circuit breaker using SCR with circuit diagram.

Answer : AC Circuit Breaker:  The circuit configuration of static AC circuit breaker using SCR is shown in the figure. When switch S' is closed, the SCRs T1 and T2 are fired in positive ... to non-availability of gate current. Thus the maximum time delay for breaking the circuit is one half-cycle.

Description : State function of starter and ELCB. (Earth Leakage Circuit Breaker)

Answer : i) Function of Starter:- 1. To prevent the high starting current OR to minimize the starting current. 2. To give supply failure protection 3. To give over load and short circuit protection ... an installation and cut off the circuit from power supply and avoid electrical shock to the person.

Description : A d.c. source has an open circuit voltage of 30 V and an internal resistance of 1.5 Ohm. A resistive load is connected to the source. Maximum power dissipated in the load is (A) 300 W (B) 150 W (C) 45 W (D) 20 W

Answer : A d.c. source has an open circuit voltage of 30 V and an internal resistance of 1.5 Ohm. A resistive load is connected to the source. Maximum power dissipated in the load is 150 W

Description : Source transformation Replace the circuit with voltage source in series with a single resistor

Answer : Source transformation Replace the circuit with voltage source in series with a single resistor

Description : An unshielded moving iron voltmeter is used to measure the voltage in an AC circuit. The stray DC magnetic field having a component along the axis will be  (1) unaffected (2) decreased (3) increased (4) either decreased or increased depending on the direction of the DC field

Answer : An unshielded moving iron voltmeter is used to measure the voltage in an AC circuit. The stray DC magnetic field having a component along the axis will be either decreased or increased depending on the direction of the DC field

Description : What is the RMS voltage in a series RL circuit, if the voltage across R and L is 256 V and 192 V respectively? A) 320 V B) 448 V C) 64 V D) None of these

Answer : What is the RMS voltage in a series RL circuit, if the voltage across R and L is 256 V and 192 V respectively? A) 320 V B) 448 V C) 64 V D) None of these

Description : A DC voltage source is connected across a series RLC circuit. Under steady-state conditions, the applied DC voltage drops entirely across the

Answer : A DC voltage source is connected across a series RLC circuit. Under steady-state conditions, the applied DC voltage drops entirely across the C only

Description : A circuit that binds the upper or lower extreme of a waveform to a fixed DC voltage level is called ______ A) DC voltage restorer B) Clamping circuit C) Both A and B D) None of these

Answer : A circuit that binds the upper or lower extreme of a waveform to a fixed DC voltage level is called ______ A) DC voltage restorer B) Clamping circuit C) Both A and B D) None of these

Description : Write the purpose of coal and ash handling unit. Also write different activities that arc carried out in this unit.

Answer : Purpose of coal and ash handling unit :-  To transport coal from coal storage to power plant. A large quantity of ash about 10 to 30 % produced in furnace, the removal of ash from boiler furnace ... disposed off.  Various methods of disposal of ash:  Mechanical system.  Pneumatic system.

Description : Compare the AC and DC Arc lamps.

Answer : AC Arc Lamp DC Arc Lamp Cross section area of electrode is same Cross section area of electrode is positive rod is twice that of negative rod Series inductor is used for stability ... supply is used for DC arc lamp Luminous efficiency is less Luminous efficiency is high

Description : Compare between Resistance welding and Arc welding on any six points.

Answer : Sr.No Parameters Resistance Welding Arc Welding 1 Type of welding Plastic/Pressure/Non-fusion welding Fusion/Non pressure welding 2 Principle of heat developed Heat ... It is suitable for mass production It is suitable for heavy job, maintenance and repair work

Description : Arc resistance  (1) increases with increase in arc current (2) decrease with increase in arc current (3) is independent of arc current (4) is independent of arc length

Answer : Arc resistance decrease with increase in arc current 

Description : For arc welding current range is usually  (1) 10 to 15 A (2) 30 to 40 A (3) 50 to 100 A (4) 100 to 350 A

Answer : For arc welding current range is usually 100 to 350 A

Description : Identify the correct combination of respective Electric arc welding and Electric resistance welding methods :  (A) Butt welding and Seam welding  (B) Hydrogen shielding and Projection welding  (C) Seam welding and Coated electrode welding  (D) Coated electrode welding and Hydrogen shielding

Answer : Identify the correct combination of respective Electric arc welding and Electric resistance welding methods :  (A) Butt welding and Seam welding  (B) Hydrogen shielding and Projection welding  ... Seam welding and Coated electrode welding  (D) Coated electrode welding and Hydrogen shielding

Description : The supply for arc welding is : 

Answer : The supply for arc welding is : Low voltage, high current ac or dc voltage

Description : Refer to the circuit below. The total absorbed (consumed) power is:

Description : Which of the following medium is employed for extinction of arc in air circuit breaker ?(a) Water (b) Oil(c) Air (d) SF6

Answer : Which of the following medium is employed for extinction of arc in air circuit breaker ?(a) Water (b) Oil(c) Air (d) SF6

Description : A battery of e.m.f. 12V supplies a current of 5A for 2 minutes. How much energy is supplied in this time?

Description : In any A.C. circuit always?

Answer : In any A.C. circuit always apparent power is more than actual power.

Description : The power factor of a D.C. circuit is always?

Answer : The power factor of a D.C. circuit is always unity.

Answer : The contacts of high voltage switches used in power system are submerged in oil. The main purpose of the oil is to extinguish the arc.

Answer : In order that current should flow without causing excessive heating or voltage drop, the relay contacts should have low contact resistance, be clean and smooth, be of sufficient size and proper shape.

Description : The voltage of transmission can be regulated by  (A) Use of tap changing transformers (B) Switching in shunt capacitors at the receiving end during heavy loads (C) Use of capacitors to neutralize the effect of series reactance (D) Any of the above methods

Answer : The voltage of transmission can be regulated by  (A) Use of tap changing transformers (B) Switching in shunt capacitors at the receiving end during heavy loads (C) Use of capacitors to neutralize the effect of series reactance (D) Any of the above methods

Description : For a 15-bus power system with 3 voltage controlled buses, the size of Jacobian matrix is

Answer : For a 15-bus power system with 3 voltage controlled buses, the size of Jacobian matrix is 25 x 25

Answer : Over voltage protection is recommended for hydro-electric generators, steam turbine generators, gas turbine generators.

Answer : The under voltage relay can be used for generators, busbars, transformers, motors.

Answer : A fuse in a motor circuit provides protection against short-circuit and overload.

Answer : Air blast circuit breakers for 400 kV power system are designed to operate in 50 millisecond.

Answer : The short circuit in any winding of the transformer is the result of impulse voltage.

Answer : The time of closing the cycle, in modern circuit breakers is 0.003 sec.