menu search
person
thumb_up_alt 0 like thumb_down_alt 0 dislike
68 views

1 Answer

A transmission line is protected by distance protection, time graded and current graded overcurrent protection.

thumb_up_alt 0 like thumb_down_alt 0 dislike
← Prev Question Next Question →

Related questions

Description :

Answer :

The interaction between a transmission line and communication line is minimized by transposing transmission as well as communication lines, increasing the height of the transmission line tower, increasing the distance between the two lines.

thumb_up_alt 0 like thumb_down_alt 0 dislike
127 views 1 answer
Description :

Transmission efficiency of a transmission line increases with the

Answer :

Transmission efficiency of a transmission line increases with the increase in power factor and voltage

thumb_up_alt 0 like thumb_down_alt 0 dislike
76 views 1 answer
Description :

Answer :

When a wave propagates on a transmission line, it suffers reflection several times at sending and other end.

thumb_up_alt 0 like thumb_down_alt 0 dislike
102 views 1 answer
Description :

Answer :

When a transmission line is energized, the wave that propagates on it is current wave and voltage wave.

thumb_up_alt 0 like thumb_down_alt 0 dislike
110 views 1 answer
Description :

Answer :

Reactance relay is preferred for phase fault on short transmission line.

thumb_up_alt 0 like thumb_down_alt 0 dislike
98 views 1 answer
Description :

Stability of a transmission line can be increased by

Answer :

Stability of a transmission line can be increased by Shunt capacitor, Series capacitor

thumb_up_alt 0 like thumb_down_alt 0 dislike
303 views 1 answer
Description :

The sag of a transmission line is least affected by (A) Self weight of the conductor. (B) Temperature of the surrounding air. (C) Current through the conductor. (D) Ice deposited on the conductor.

Answer :

The sag of a transmission line is least affected by Current through the conductor.

thumb_up_alt 0 like thumb_down_alt 0 dislike
116 views 1 answer
Description :

what is mean by medium transmission line ?

Answer :

The transmission line which have length between 80 km to 250 km is known as medium transmission line.

thumb_up_alt 0 like thumb_down_alt 0 dislike
92 views 1 answer
Description :

what is mean by short transmission line ?

Answer :

The transmission lines which have length less than 80 km is known as short transmission lines.

thumb_up_alt 0 like thumb_down_alt 0 dislike
95 views 1 answer
Description :

what is mean by long transmission line ?

Answer :

The transmission line which have length more than 250 km are known as long transmission lines.

thumb_up_alt 1 like thumb_down_alt 0 dislike
77 views 1 answer
Description :

Answer :

Large internal faults are protected by merz price percentage differential protection.

thumb_up_alt 0 like thumb_down_alt 0 dislike
135 views 1 answer
Description :

A 50Ω transmission line is terminated in an impedance of 20-j50. What will be the reflection coefficient? A) 0.69 B) 1.69 C) 6.9 D) 16.9 

Answer :

A 50Ω transmission line is terminated in an impedance of 20-j50. What will be the reflection coefficient? A) 0.69 B) 1.69 C) 6.9 D) 16.9 

thumb_up_alt 0 like thumb_down_alt 0 dislike
265 views 1 answer
Description :

In a transmission line if booster transformers are to be used, preferred location will be  (A) At the receiving end (B) At the sending end (C) At the intermediate point (D) Anywhere in the line 

Answer :

In a transmission line if booster transformers are to be used, preferred location will be At the intermediate point

thumb_up_alt 0 like thumb_down_alt 0 dislike
251 views 1 answer
Description :

A transmission line has 1 P.0 impedance on a base of 11 KV, 100 MVA. On a base of 55 KV. it will have a P.0 impedance of

Answer :

A transmission line has 1 P.0 impedance on a base of 11 KV, 100 MVA. On a base of 55 KV. it will have a P.0 impedance of 0.02 P.U

thumb_up_alt 0 like thumb_down_alt 0 dislike
371 views 1 answer
Description :

For a short transmission line with r/x ratio of is 1.0, the regulation will be zero when the load power factor is

Answer :

For a short transmission line with r/x ratio of is 1.0, the regulation will be zero when the load power factor is 0.707 lead

thumb_up_alt 0 like thumb_down_alt 0 dislike
145 views 1 answer
Description :

A transmission line of 200 km has a certain A, B, C and D parameters. If the length is reduced to 60 km

Answer :

A transmission line of 200 km has a certain A, B, C and D parameters. If the length is reduced to 60 km A increases, B decreases

thumb_up_alt 0 like thumb_down_alt 0 dislike
97 views 1 answer
Description :

The sending end and receiving end voltages of a three-phase transmission line are 10 kV/ph and 9.5 kV/ph, respectively. If the resistance drop is 150 V/ph and receiving end power factor is 0.8, the sending end power factor is (A) 0.745 lagging (B) 0.775 lagging (C) 0.8 lagging (D) 0.85 lagging

Answer :

Vscos¢s-Vrcos¢r=IR

thumb_up_alt 0 like thumb_down_alt 0 dislike
2.9k views 2 answers
Description :

What are the losses in a transmission line?

thumb_up_alt 0 like thumb_down_alt 0 dislike
55 views 0 answers
Description :

State the limitations of EHVAC transmission line. 

Answer :

Following are the Limitations of EHVAC Transmission:   1. Insulation cost increases as voltage increases 2. Skin effect is more 3. Proximity effect is more. 4. Corona loss increases. 5. Radio ... 18. EHVAC is economical only for bulk amount of power is to be transmitted over long distance. 

thumb_up_alt 0 like thumb_down_alt 0 dislike
105 views 1 answer
Description :

State line parameters of transmission line. 

Answer :

Following are the of Line parameters of transmission line:  1. Resistance  2. Inductance  3. Capacitance

thumb_up_alt 0 like thumb_down_alt 0 dislike
40 views 1 answer
Description :

State the impact of inductance and resistance on transmission line performance

Answer :

Impact of inductance on transmission line: 1) It causes IXL drop in transmission line which affects regulation. 2) It is the only parameter which decides power transmission capacity of line i. ... is very small, it causes losses, temperature rise& poor voltage regulation so it cannot be neglected

thumb_up_alt 0 like thumb_down_alt 0 dislike
102 views 1 answer
Description :

effect of inductance and capacitance on performance of transmission line.

Answer :

Following are the effect on performance of transmission line:  1. Due to inductance (L) voltage drop in transmission line produces.  2. Capacitor (C) draws charging current ... , transmission line efficiency, voltage regulation & also power factor of transmission line gets affected. 

thumb_up_alt 1 like thumb_down_alt 0 dislike
81 views 1 answer
Description :

While calculating performance of medium transmission line, what assumptions are made in case of (i) Nominal 'T' Method (ii) Nominal 'TT' Method. 

Answer :

(i) Assumptions are made in case of Nominal 'T' Method:  a. It is assume that line capacitance is connected at center of transmission line. b. It is assume that half ... assumed that transmission line resistance & reactance per phase is connected in between two half transmission line capacitance 

thumb_up_alt 0 like thumb_down_alt 0 dislike
83 views 1 answer
Description :

HVDC transmission line in India: 

Answer :

HVDC transmission line in India:  S.N .  From To  Voltage 1 Rihand (U.P) (from 1990) Dadri +- 500 KV (bipolar) 2 Talcher- is the biggest ... (Chandrapur) Western Region  140KV   8 Connecting Southern region(Vizag- Gajuwaka) Eastern Region 140KV 

thumb_up_alt 0 like thumb_down_alt 0 dislike
85 views 1 answer
Description :

effect of line parameter on performance of transmission line. 

Answer :

Following are the effect of line parameter on performance of transmission line:  1. Due to resistance (R), voltage drop in transmission line & copper losses in transmission line ... transmission line efficiency, voltage regulation & also power factor of transmission line gets affected. 

thumb_up_alt 0 like thumb_down_alt 0 dislike
53 views 1 answer
Description :

Why is transmission line 11kV, 33kV 66kV Not Is 10kV, 20kV, 30kV ?

Answer :

10kv plus to compensate losses in olden days 1kv were added and transmitted. Since all equipment used for transmission have a multiple of 11 from olden days, still that is being followed even though the losses are ... voltages, multiples of 11 is eazy for winding ratios.. i.e. 11kv to 33kv is 1:3.

thumb_up_alt 0 like thumb_down_alt 0 dislike
163 views 3 answers
Description :

Series capacitive compensation in EHV transmission line is used to

Answer :

To maintain voltage stability 

thumb_up_alt 0 like thumb_down_alt 0 dislike
393 views 2 answers
Description :

Thyristor can be protected from over voltages by using

Answer :

Thyristor can be protected from over voltages by using Voltage clamping device

thumb_up_alt 0 like thumb_down_alt 0 dislike
92 views 1 answer
Description :

The voltage of transmission can be regulated by  (A) Use of tap changing transformers (B) Switching in shunt capacitors at the receiving end during heavy loads (C) Use of capacitors to neutralize the effect of series reactance (D) Any of the above methods

Answer :

The voltage of transmission can be regulated by  (A) Use of tap changing transformers (B) Switching in shunt capacitors at the receiving end during heavy loads (C) Use of capacitors to neutralize the effect of series reactance (D) Any of the above methods

thumb_up_alt 0 like thumb_down_alt 0 dislike
72 views 1 answer
Description :

Answer :

The inductive interference between power and communication line can be minimized by transposition of the power line, transposition of the communication line.

thumb_up_alt 0 like thumb_down_alt 0 dislike
96 views 1 answer
Description :

Answer :

Ungrounded neutral transmission system is not recommended because of system insulation being overstressed due to over voltages, insulation overstress may lead to failure and subsequent phase to phase faults, being inadequately protected against ground fault.

thumb_up_alt 0 like thumb_down_alt 0 dislike
54 views 1 answer
Description :

A lightening arrester connected between the line and earth in a power system  (1) protects the terminal equipment against travelling surges (2) protects the transmission line against direct lightening strokes (3) suppresses high frequency oscillations in the line (4) reflects back the travelling wave approaching it

Answer :

A lightening arrester connected between the line and earth in a power system protects the terminal equipment against travelling surges

thumb_up_alt 0 like thumb_down_alt 0 dislike
90 views 1 answer
Description :

The reactive power transfer over a line mainly depends on

Answer :

The reactive power transfer over a line mainly depends on lVsl- lVRl

thumb_up_alt 0 like thumb_down_alt 0 dislike
363 views 1 answer
Description :

lf a travelling-wave travelling along a loss-less overhead line does not result in any reflection after it has reached the far end, then the far end of the line is

Answer :

lf a travelling-wave travelling along a loss-less overhead line does not result in any reflection after it has reached the far end, then the far end of the line is terminated into a resistance equal to surge impedance of the line

thumb_up_alt 0 like thumb_down_alt 0 dislike
73 views 1 answer
Description :

The surge impedance for over head line is taken as  (1) 10-20 ohms (2) 50-60 ohms (3) 100-200 ohms (4) 1000-2000 ohms

Answer :

The surge impedance for over head line is taken as 100-200 ohms

thumb_up_alt 0 like thumb_down_alt 0 dislike
82 views 1 answer
Description :

Answer :

Impedance relays are used for phase faults on long line.

thumb_up_alt 0 like thumb_down_alt 0 dislike
70 views 1 answer
thumb_up_alt 0 like thumb_down_alt 0 dislike
93 views 0 answers
Description :

requirements or properties of the line supports used in transmission and distribution.  

Answer :

Following are requirements or properties of the line supports used in transmission and distribution. 1. High mechanical strength:-  It should have high mechanical strength to withstand against - ... . 8. Appearance: It should have good appearance or They must be of pleasing shape

thumb_up_alt 0 like thumb_down_alt 0 dislike
48 views 1 answer
Description :

How many insulator disc used for 33 kV transmission voltage line?

Answer :

5,As 33kv is Vrms

thumb_up_alt 0 like thumb_down_alt 0 dislike
113 views 1 answer
Description :

Explain following techniques related to energy conservation in transmission and distribution system. (i) By balancing phase currents (ii) Variable technical losses (I2R losses).

Answer :

(i) Balancing Phase currents: Proper (healthy balanced) three phase loads always draw equal currents in all lines but single phase loads in the 3 phase 4 wire system or loads connected between two ... . 11) Minimize I2R losses. 12) Balance the load currents. 13) Regulate the system voltages.

thumb_up_alt 0 like thumb_down_alt 0 dislike
120 views 1 answer
Description :

In voltage source converter based HVDC transmission system the active power is controlled by changing (A) phase angle of the converter ac input voltage (B) supply frequency of the converter ac input voltage (C) magnitude of the converter ac input voltage (D) DC voltage at the inverter terminals

Answer :

In voltage source converter based HVDC transmission system the active power is controlled by changing phase angle of the converter ac input voltage

thumb_up_alt 0 like thumb_down_alt 0 dislike
112 views 1 answer
Description :

Corona loss in transmission lines can be reduced by (A) using small diameter conductors (B) using bundled conductors (C) using less spacing between conductors (D) increasing the transmission line voltage

Answer :

Corona loss in transmission lines can be reduced by using bundled conductors

thumb_up_alt 0 like thumb_down_alt 0 dislike
104 views 1 answer
Description :

What is meant by extra high voltage transmission?

Answer :

HT & LT  two types transmission in industrial line 

thumb_up_alt 0 like thumb_down_alt 0 dislike
100 views 1 answer
Description :

Answer :

Annual depreciation as per straight line method, is calculated by the capital cost minus the salvage value, is divided by the number of years of life.

thumb_up_alt 0 like thumb_down_alt 0 dislike
52 views 1 answer
Description :

If 3000 kW power is to be transmitted over a distance of 30 km, the desirable transmission voltage will be.  (A) 11 kV (B) 33 kV (C) 66 kV (D) 132 kV

Answer :

By

thumb_up_alt 0 like thumb_down_alt 0 dislike
3.4k views 2 answers
Description :

The power flow problem mathematical model for a linear transmission network (A) is non-linear (B) is linear (C) considers time variation of generation (D) does not consider tap-changing transformers

Answer :

The power flow problem mathematical model for a linear transmission network is non-linear

thumb_up_alt 0 like thumb_down_alt 0 dislike
67 views 1 answer
Description :

If a 5-bus test system contains 6 transmission lines and one transformer, how many non-zero elements are there in the system Y-bus ? (A) 25 (B) 12 (C) 11 (D) 19

Answer :

If a 5-bus test system contains 6 transmission lines and one transformer, 19 non-zero elements are there in the system Y-bus.

thumb_up_alt 0 like thumb_down_alt 0 dislike
2.9k views 1 answer
Description :

What is the job of a servo in a transmission?

Answer :

servo motor use in many types mechanism so its verius type of transmission wich type you need to know 

thumb_up_alt 0 like thumb_down_alt 0 dislike
72 views 1 answer
Description :

State the effects of low power factor on efficiency and voltage regulation of short transmission lines. 

Answer :

i) Effect of Low power factor on efficiency:- When power factor of load reduces current drawn by transmission line increases so copper losses in transmission line increases, hence transmission ... increases, so voltage drop in transmission line increases so regulation increases. (Become Poor) 

thumb_up_alt 0 like thumb_down_alt 0 dislike
113 views 1 answer
Description :

State the advantages of use of high voltage in transmission of Electric power. 

Answer :

Advantages: 1. As Transmission voltage increases, current decreases. 2. As current decreases, cross section of conductor decreases. 3. As cross section of conductor decreases, its ... high voltage transmission line, successful interconnection of transmission line is possible than low voltage. 