Air blast circuit breaker is used for repeated duty.

thumb_up_alt 0 like thumb_down_alt 0 dislike

Related questions

Answer : Air blast circuit breakers for 400 kV power system are designed to operate in 50 millisecond.

Description : The current zero interruption, in oil and air blast circuit breakers, is achieved by?

Answer : The current zero interruption, in oil and air blast circuit breakers, is achieved by lengthening of the gap, cooling and blast effect.

Description : ln a minimum oil circuit breaker the oil is used

Answer : ln a minimum oil circuit breaker the oil is used to act as circuit breaking medium only

Description : For selecting a circuit breaker, ______ should be determined.  (A) initial current that flows on occurrence of a short circuit only (B) transient current that flows at the time of circuit interruption only (C) resonant frequency only (D) (A) and (B) 

Answer : For selecting a circuit breaker, ______ should be determined. (A) initial current that flows on occurrence of a short circuit only (B) transient current that flows at the time of circuit interruption only (C) resonant frequency only (D) (A) and (B) 

Description : The arc temperature in Oil Circuit Breaker may reach up to_______.  (A) 5,000° K (B) 8,000° K (C) 10,000° K (D) None of the above

Answer : The arc temperature in Oil Circuit Breaker may reach up to 5,000° K 

Description : The number of cycles in which a high speed circuit breaker can complete its operation is  (A) 3 to 8 (B) 10 to 18 (C) 20 to 30 (D) 40 to 50

Answer : The number of cycles in which a high speed circuit breaker can complete its operation is 3 to 8

Description : A circuit breaker is designed to protect an electrical circuit from damage caused by :  (A) Over load (B) Short circuit (C) Over current (D) All of the above

Answer : A circuit breaker is designed to protect an electrical circuit from damage caused by :  (A) Over load (B) Short circuit (C) Over current (D) All of the above

Description : The Minimum Oil Circuit Breaker (MOCB) is named because of :  (A) Reduced requirement of oil (B) Reduced requirement of air (C) All of the above (D) None of the above

Answer : The Minimum Oil Circuit Breaker (MOCB) is named because of : Reduced requirement of oil 

Answer : Arc in a circuit breaker is interrupted at zero current.

Answer : The arc voltage produced in A.C. circuit breaker is always in phase with the arc current.

Answer : In a circuit breaker the basic problem is to transmit large power.

Answer : Ionization in circuit breaker is facilitated by high temperature, increase of mean free path, increasing field strength.

Answer : The voltage appearing across the contacts after opening of the circuit breaker is called recovery voltage.

Answer : Magnetic circuit breaker has instantaneous trip action.

Answer : Thermal circuit breaker has delayed trip action.

Answer : The arcing contacts in a circuit breaker are made of copper tungsten alloy.

Description : what is SF6 circuit breaker?

Answer : A circuit breaker in which SF6 under pressure gas is used toextinguish the arc is calledSF6 circuit breaker. SF6 (sulphur hexafluoride) gas has excellent dielectric , arc quenching, chemical and other physical properties and has proved its ...

Description : Which of the following is used in a circuit breaker as the medium in which the arc forms? A) Insulating gas B) Insulating oil C) Vacuum D) All the above

Answer : Which of the following is used in a circuit breaker as the medium in which the arc forms? A) Insulating gas B) Insulating oil C) Vacuum D) All the above

Description : Explain working of static AC circuit breaker. 

Answer : Static AC Circuit breaker: The circuit configuration of static AC circuit breaker using SCR is shown in the figure. When switch S' is closed, the SCRs T1 and T2 are fired in positive ... non-availability of gate current. Thus the maximum time delay for breaking the circuit is one half-cycle.

Description : Explain working of AC circuit breaker using SCR with circuit diagram.

Answer : AC Circuit Breaker:  The circuit configuration of static AC circuit breaker using SCR is shown in the figure. When switch S' is closed, the SCRs T1 and T2 are fired in positive ... to non-availability of gate current. Thus the maximum time delay for breaking the circuit is one half-cycle.

Description : State function of starter and ELCB. (Earth Leakage Circuit Breaker)

Answer : i) Function of Starter:- 1. To prevent the high starting current OR to minimize the starting current. 2. To give supply failure protection 3. To give over load and short circuit protection ... an installation and cut off the circuit from power supply and avoid electrical shock to the person.

Description : Breaking capacity of a circuit breaker is usually expressed in terms of  (1) Ampere (2) Volts (3) MW (4) MVA

Answer : Breaking capacity of a circuit breaker is usually expressed in terms of MVA

Description : The arc voltage in a circuit breaker is :

Answer : The arc voltage in a circuit breaker is : in phase with the arc current

Description : Which circuit is used as amplitude comparator?

Answer : Schmitt trigger circuit is used as amplitude comparator.

Description : A dummy strain gage is used in a quarter bridge strain gage circuit to :  (A) compensate for changes in temperature and lead wire resistance  (B) produce more output voltage from the bridge  (C) increase the sensitivity of the bridge  (D) compensate lead wire resistance only

Answer : A dummy strain gage is used in a quarter bridge strain gage circuit to : compensate for changes in temperature and lead wire resistance 

Description : An unshielded moving iron voltmeter is used to measure the voltage in an AC circuit. The stray DC magnetic field having a component along the axis will be  (1) unaffected (2) decreased (3) increased (4) either decreased or increased depending on the direction of the DC field

Answer : An unshielded moving iron voltmeter is used to measure the voltage in an AC circuit. The stray DC magnetic field having a component along the axis will be either decreased or increased depending on the direction of the DC field

Description : What is an air ionizer for?

Answer : In recent years, air ionizers have become more and more popular in the household appliances market . And this is quite justified, because their use can significantly improve air quality and minimize the ... advice and, together with a doctor, decide on the possibility of further use of the device.

Answer : Natural air cooling is generally restricted for transformers up to 1.5 MVA .

Description : Which of the following medium is employed for extinction of arc in air circuit breaker ?(a) Water (b) Oil(c) Air (d) SF6

Answer : Which of the following medium is employed for extinction of arc in air circuit breaker ?(a) Water (b) Oil(c) Air (d) SF6

Description : Wall-mounted air conditioners: what to consider when choosing?

Answer : Home and office climatic equipment in practice is mainly represented by wall-mounted air conditioners or split systems. The variety of design of split-systems allows not only to successfully fit ... are the famous Japanese brands Daikin, Mitsubishi Electric, Toshiba, General, Fujitsu and Panasonic.

Description : Compare reciprocating and rotary air compressor

Answer : Reciprocating compressor Rotary compressor  1. Compression of air takes place with help of piston and cylinder arrangement with reciprocating motion of piston. 1. Compression of air takes place ... High 12. More Starting torque required 12. Less Starting torque required

Description : Graph indicating changes in pollutants level w.r.t air fuel ratio

Answer : Graph indicating changes in pollutants level w.r.t air fuel ratio

Description : Why is it necessary to keep air gaps in magnetic circuits as small as possible?

Description :  applications of compressed air

Answer : 1) To drive air motors in coal mines. 2) To inject fuel in air injection diesel engines. 3) To operate pneumatic drills, hammers, hoists, sand blasters. 4) For cleaning purposes. 5) To cool large ... and farm maintenance. 7) In vehicle to operate air brake. 8) For spray painting in paint industry.

Description : Explain fuel system and air intake system in diesel electric power plant.

Answer : Fuel system and air intake system in diesel electric power plant :  Fuel system: It consists of storage tank, strainers, fuel transfer pump and all day fuel tank. The fuel oil is supplied ... Filters are provided to remove dust particles from air which may act as abrasive in the engine cylinder.

Description : State the functions of following elements: i) Diesel engine system ii) Air intake system iii) Engine exhaust system iv) Engine starting system.

Answer : i) Diesel engine system:-  Four strokes Two strokes ii) Air intake system:- Air intake system is provided to supply air to engine cylinder for fuel combustion.  iii) Engine exhaust system ... provided to rotate the engine initially until the firing starts and engine run under its own power. 

Description : Describe with neat diagram air friction damping. 

Answer : Air Friction Damping: Here air trapped in the chamber works as damping medium for the piston movement connected to the spindle. The piston moves in the air chamber. The clearance between piston and ... will be the damping torque, bringing the pointer to the equilibrium position quickly. 

Description : What happens to the capacitance if mica is inserted between the plates of an air capacitor? A) The capacitance increases B) The capacitance decreases C) The capacitance remains the same D) The capacitance becomes zero

Answer : What happens to the capacitance if mica is inserted between the plates of an air capacitor? A) The capacitance increases B) The capacitance decreases C) The capacitance remains the same D) The capacitance becomes zero

Answer : Susceptibility of the air medium is zero.

Description : An air gap is usually inserted in magnetic circuits to?

Answer : An air gap is usually inserted in magnetic circuits to prevent saturation.

Answer : Two-value capacitor motor finds increased application as compressor motor in small home air-conditioners because it has low starting as well as running currents at relatively high power factor.

Description : A relay used for protection of motors against overload is :  (A) Impedance relay (B) Electromagnetic attraction type (C) Thermal relay (D) Buchholz's relay

Answer : A relay used for protection of motors against overload is : Thermal relay

Description : Earthing switch is used for?  (A) Measuring of safety voltage (B) Protection of equipment from ground faults (C) Discharging residual energies (D) All of the above 

Answer : Earthing switch is used for?  (A) Measuring of safety voltage (B) Protection of equipment from ground faults (C) Discharging residual energies (D) All of the above 

Description : A negative sequence relay is used for protection of  (1) Generator (3) Motor (2) Transformer (4) Long Transmission lines

Answer : A negative sequence relay is used for protection of Generator 

Description : Regulating-transformers are used in power systems for control of

Answer : Regulating-transformers are used in power systems for control of power flow

Description : Surge absorbers are used for protection against

Answer : Surge absorbers are used for protection against low voltage high frequency oscillations

Answer : A switchgear is device used for switching, controlling and protecting the electrical circuit and equipment.

Answer : The material used for fuse must have low melting point and high specific resistance.

Answer : The inverse definite mean time relays are used for over current and earth fault protection of transformer against internal short-circuits.