D.C. shunt relays are made of?

1 Answer

D.C. shunt relays are made of many turns of thin wire.

Like 0 like Dislike 0 dislike

Related questions

Description : List the main parts of D.C. motor

Answer : Main parts of D.C. motor and their functions:  Part Functions Yoke i) Provides mechanical support for poles. ii) Acts as protecting cover for machine. iii) Carries magnetic flux. ... a fixed physical position relative to the stator.  Shaft Used to transfer mechanical power 

Description : Write two applications of D.C. series motor. 

Answer : The applications of D.C. series motor: 1. Cranes 2. Hoists 3. Trolley and cars 4. Conveyors 5. For traction work i.e. electric locomotives 6. Elevator 7. Air compressor

Description : State the principle of operation of d.c. motor.

Answer : When a current carrying conductor is placed in a magnetic field, the conductor experiences the force. The magnitude of force is given by F = BIL newton  where F – Force   B – maximum flux density   I – Current   L – Length of conductor

Description : Briefly define each of the following: (a) 1 coulomb (b) 1 volt (c) 1 ampere (d) 1 ohm.

Description : IDMT relays are used to protect the transformer against :  (A) Internal short -circuits (B) Open circuits (C) External short circuits (D) Oil leakage

Answer : IDMT relays are used to protect the transformer against : External short circuits

Answer : The inverse definite mean time relays are used for over current and earth fault protection of transformer against internal short-circuits.

Answer : The single phasing relays are used for the protection of three phase motors.

Answer : Impedance relays are used for phase faults on long line.

Answer : Discrimination between main and back up protection is provided by the use of relays which are slow.

Answer : To protect most of the electrical equipment handling low power, the types of relays used are thermocouple, electronic and bimetallic.

Answer : Protective relays are devices that detect abnormal conditions in electrical circuits by measuring constantly the electrical quantities which differ during normal and abnormal conditions.

Answer : Directional relays are based on flow of power.

Answer : Thermal overload relays are used to protect the motor against overcurrent due to heavy loads.

Answer : Overload relays are of induction, solid state, thermal, electromagnetic type.

Answer : Relays can be designed to respond to changes in resistance, reactance or impedance voltage and current, light intensity, temperature.

Description : How many types of types of relays are there?

Description : Consider the following statements. Which of these statements are correct ?  (1) Reactance relays are preferred for ground fault relaying  (2) Impedance relays are most suitable for:protecting long transmission lines  (3) Mho relays are best ... (1) and (3) (C) (2) and (4) (D) (1), (2) and (4)

Answer : Consider the following statements. Which of these statements are correct ?  (1) Reactance relays are preferred for ground fault relaying  (2) Impedance relays are most suitable for:protecting long transmission lines  (3) Mho relays are ... (1) and (3) (C) (2) and (4) (D) (1), (2) and (4)

Answer : Shunt capacitance is neglected while considering short transmission line.

Description : Brushes of DC machine are made up of ?

Answer : Brushes of DC machine are made up of carbon.

Description : From which material field coils of DC generator are made of?

Answer : Field coils of DC generator are usually made of copper.

Description : A switch tail ring counter is made by using a single D-FF. The resulting circuit is (A) T-FF (B) D-FF (C) SR-FF (D) JK-FF

Answer : A switch tail ring counter is made by using a single D-FF. The resulting circuit is T-FF

Description : The IC chips, used in computers, is made of  (1) Iron oxide (2) Silicon (3) Graphite (4) Silica

Answer : 2 These are made on silicon wafers which is aa semi conductor. ...

Answer : Standard resistor is made from maganin.

Answer : The rotor of a hysteresis motor is made of chrome steel.

Description : A synchronous motor can be made self starting by providing?

Answer : A synchronous motor can be made self-starting by providing damper bar.

Answer : D.C. shunt motors are used for driving machine tools.

Answer : If a D.C. shunt motor is working at full load and if shunt field circuit suddenly opens this will make armature to take heavy current, possibly burning it.

Answer : The purpose of retardation test on D.C. shunt machines is to find out stray losses.

Answer : If the speed of a D.C. shunt motor is increased, the back e.m.f. of the motor will increase.

Answer : For a D.C. shunt motor if the excitation is changed torque will change but power will remain constant.

Answer : The speed of a D.C. shunt motor can be increased by increasing the resistance in field circuit.

Answer : The armature torque of the D.C. shunt motor is proportional to armature current.

Answer : As the load is increased the speed of D.C. shunt motor will reduce slightly.

Answer : In a D.C. shunt motor, under the conditions of maximum power, the current in the armature will be more than full-load current.

Answer : In case of D.C. shunt motors the speed is dependent on back e.m.f. only because flux is practically constant in D:C. shunt motors.

Answer : In a D.C. shunt motor, speed is independent of armature current.

Answer : The speed of a D.C. shunt motor more than its full-load speed can be obtained by decreasing the field current.

Answer : In D.C. shunt motors as load is reduced the speed will remain almost constant.

Answer : If the field of a D.C. shunt motor gets opened while motor is running the motor will attain dangerously high speed.

Description : DC shunt motor

Answer : .embed-container { position: relative; padding-bottom: 56.25%; height: 0; overflow: hidden; max-width: 100%; } .embed-container iframe, .embed-container object, .embed-container embed { position: absolute; top: 0; left: 0; width: 100%; height: 100%; }

Description : If field current is decreased in shunt dc motor, the speed of the motor (a) remains same. (b) increases. (c) decreases. (d) none of the above.

Answer : increases

Description : State any four applications of DC shunt motor.

Answer : Applications of DC shunt motor: 1) Lathe machines 2) drilling machines 3) milling machines 4) Printing machinery 5) Paper industry 6) centrifugal and reciprocating pumps 7) blowers 8)fans

Description : Why does the speed of a DC shunt motor decrease as the load increases?

Answer : Because if the load is increasing then the torque must also be increase. If not then the speed of motor will decrease.

Description : State the use of shunt and series resistance used in extension of meter.

Answer : Use of shunt and series resistance: i) Use of shunt: To extend the range of Ammeter. ii) Use of series resistance: To extend the range of Voltmeter.

Description : In which of the following transmission lines, the value of the Shunt admittance should be approximated to zero ? (A) A 66 kV 35 km long line (B) A 132 kV 200 km long line (C) A 220 kV 300 km long line (D) A 400 kV 500 km long line

Answer : In which of the following transmission lines, the value of the Shunt admittance should be approximated to zero ? (A) A 66 kV 35 km long line (B) A 132 kV 200 km long line (C) A 220 kV 300 km long line (D) A 400 kV 500 km long line

Description : A 240 V, dc shunt motor draws 15 A while supplying the rated load at a speed of 80 rad/s. The armature resistance is 0.5 W and the field winding resistance is 80 W. The net Voltage across armature resistance at the time of plugging will be

Answer : A 240 V, dc shunt motor draws 15 A while supplying the rated load at a speed of 80 rad/s. The armature resistance is 0.5 W and the field winding resistance is 80 W. The net Voltage across armature resistance at the time of plugging will be 474 V

Description : Shunt compensation in an EHV line is used to (A) Improve stability. (B) Improve the voltage profile. (C) Reduce the fault level. (D) Substitute for synchronous phase modifier.

Answer : Shunt compensation in an EHV line is used to Improve the voltage profile.

Description : A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is

Answer : A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is 36 Ohm

Description : A shunt fault is characterized by (A) Increase in current, frequency and pf (B) Increase in current, reduction in frequency and pf (C) Increase in current and frequency, reduction in pf (D) Decrease in current and frequency

Answer : B

← Prev Question Next Question →