Primary winding of a transformer could either be a low voltage or high voltage winding.

thumb_up_alt 0 like thumb_down_alt 0 dislike

Related questions

Description : In a transformer the resistance between its primary and secondary should be?

Answer : In a transformer the resistance between its primary and secondary should be infinity.

Description : A certain transformer has 200 turns in the primary winding, 50 turns in the secondary winding and 120 volts applied to the primary. What is the voltage across the secondary?  (A) 30 Volts (B) 480 Volts (C) 120 Volts (D) 60 Volts

Answer : A certain transformer has 200 turns in the primary winding, 50 turns in the secondary winding and 120 volts applied to the primary. What is the voltage across the secondary?  (A) 30 Volts (B) 480 Volts (C) 120 Volts (D) 60 Volts

Answer :  Sandwich type winding is used in 3 phase shell-type transformer.

Answer : The short circuit in any winding of the transformer is the result of impulse voltage.

Answer : yes High Voltage side of Transformer winding have more number of turns. and low voltage side of Transformer winding have less number of turns.

Answer : In the transformer low voltage winding has got more cross-sectional area.

Answer : High voltage winding in a transformer has more number of turns.

Answer : High voltage winding of the transformer has less cross-sectional area.

Answer : An ideal transformer has infinite values of primary and secondary inductances. The statement is false.

Description : Define: primary and secondary distribution system 

Answer : i) Primary Distribution:  It is a 3-phase, 3-wire transmission line connected in between receiving substation to Distribution substation. OR It is link between receiving substation & ... substation to consumer line. OR It is link between distribution transformer substation & consumer. 

Description : Write example of each type (i) Primary transducer (ii) Active transducer (iii) Electrical transducer (iv) Digital transducer

Answer : (i) Active transducer:-Thermocouple, piezoelectric, photovoltaic cell (ii) Primary transducer:- Bourdon tube, bellows, (iii) Electrical transducer.:- LVDT,RVDT, Hall effect, strain gauge, ... , optical pyrometer, radiation pyrometer (iv) Digital transducer:- Linear Encoder, digital taco generator

Description : Compare primary and secondary instruments.

Answer : Primary instruments  Secondary instruments  Gives magnitude of quantity in terms of physical constants of instrument  Gives reading directly of the quantity measured.  Need no calibration  ... .  e.g. magnetic meter, induction meter, hotwire meter and electrostatic meter 

Answer : The primary reason for low power factor is supply system is due to installation of induction motors.

Description : What is the definition of a primary instrument?

Description : Primary and Backup Protection

Answer : Primary and Backup Protection  B,D,G,I are the primary protection. A,C,H,J are the backup protection. About 90% of faults are clear by Primary Protection. So ... ordinated backup (primary is at various station  and backup is at control room with computer)

Description : The primary winding of a 220/6 V, 50 Hz transformer is energised from 110 V, 60 Hz supply. The secondary output voltage will be (A) 3.6 V. (B) 2.5 V. (C) 3.0 V. (D) 6.0 V.

Answer : The primary winding of a 220/6 V, 50 Hz transformer is energised from 110 V, 60 Hz supply. The secondary output voltage will be 3.0 V.

Description : State advantages of short pitch winding over full pitch winding in alternators. 

Answer : Advantages of Short Pitch Winding over Full Pitch Winding in Alternators: 1) Short pitching reduces the amount of copper needed for end connection when compared with full pitched coil. 2) They ... reduced, thereby increasing the efficiency. 4) The power quality of generated emf is improved. 

Answer : It is the wire wound around a aluminium metal it is found commonly in transformers or motors

Description : Damper winding in a synchronous motor

Answer : Damper winding in a synchronous motor Serves to start the motor.

Description : A _________ is used to measure the stator % winding temperature of the generator.  (A) Thermocouple (B) Pyrometer (C) Resistance thermometer (D) Thermometer

Answer : A Resistance thermometer is used to measure the stator % winding temperature of the generator. 

Description : A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is

Answer : A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is 36 Ohm

Description : A 36 slot, 4 -pole, dc machine has a simplex lap winding with two conductors per slot. The back pitch and front pitch adopted could be respectively

Answer : A 36 slot, 4 -pole, dc machine has a simplex lap winding with two conductors per slot. The back pitch and front pitch adopted could be respectively 19,17

Description : Damper winding is provided in 3 phase synchronous motors to :

Answer : Damper winding is provided in 3 phase synchronous motors to : provide starting torque and prevent hunting

Description : Aluminium is not used as winding wire for the armature of a dc machine because  (1) aluminium has low resistivity (2) a large winding space is taken by aluminium conductors and creates ... ) the thermal conductivity of aluminium is low (4) aluminium has low conductivity as compared to copper

Answer : Aluminium is not used as winding wire for the armature of a dc machine because  (2) a large winding space is taken by aluminium conductors and creates jointing problems (3) the thermal conductivity of aluminium is low (4) aluminium has low conductivity as compared to copper

Answer : Wave winding is composed of that even number which is exact multiple of poles + 2.

Answer : Lap winding is composed of any even number of conductors.

Answer : In D.C. generators, lap winding is used for low voltage, high current.

Answer : In the case of lap winding resultant pitch is difference of front and back pitches.

Answer : In case of D.C. machine winding, number of commutator segments is equal to number of armature coils.

Answer : In lap winding, the number of brushes is always same as the number of poles.

Answer : The resistance of armature winding depends on length of conductor, cross-sectional area of the conductor, number of conductors.

Answer : In D.C. machines fractional pitch winding is used to reduce the sparking.

Answer : The starting winding of a single-phase motor is placed in stator.

Answer : If starting winding of a single-phase induction motor is left in the circuit, it will draw excessive current and overheat.

Answer : Starting winding of a single phase motor of a refrigerator is disconnected from the circuit by means of a magnetic relay.

Answer : Centrifugal switch disconnects the auxiliary winding of the motor at about 70 to 80 percent of synchronous speed.

Answer : The purpose of stator winding in the compensated repulsion motor is to improve power factor and provide better speed regulation.

Answer : In split phase motor main winding is of thick wire placed at the bottom of the slots.

Answer : In A.C. series motor compensating winding is employed to reduce sparking at the brushes.

Answer : In split-phase motor auxiliary winding is of thin wire placed at the top of the slots.

Description : The running winding of a single phase motor on testing with meggar is found to be ground. Most probable location of the ground will be?

Answer : The running winding of a single phase motor on testing with meggar is found to be ground. Most probable location of the ground will be at the slot edge where coil enters or comes out of the slot.

Answer : A centrifugal switch is used to disconnect starting winding when motor has picked up about 50 to 70 per cent of rated speed.

Answer : In a capacitor start motor, the phase displacement between starting and running winding can be nearly 90°.

Answer : In a capacitor start and run motors the function of the running capacitor in series with the auxiliary winding is to improve power factor.

Answer : In a split phase motor, the running winding should have low resistance and high inductance.

Answer : If the field winding of an unloaded salient pole synchronous motor is open circuited, the motor will stop.

Description : The damping winding in synchronous motor is generally used to?

Answer : The damping winding in synchronous motor is generally used to provide starting torque and prevent hunting.

Description : In synchronous motor, does the winding losses vary with load?

Answer : No, in the synchronous motor the winding losses do not vary with load.

Description :  An AC supply of 230 V is applied to a half-wave rectifier circuit through a transformer having primary to secondary turn’s ratio 12:1. The peak inverse voltage is A) 8.62 V B) 12 V C) 19.17 V D) 27.11 V 

Answer :  An AC supply of 230 V is applied to a half-wave rectifier circuit through a transformer having primary to secondary turn’s ratio 12:1. The peak inverse voltage is A) 8.62 V B) 12 V C) 19.17 V D) 27.11 V 

Description : What will happen if the primary of a transformer is connected to D.C. supply?  (A) Transformer will operate with low efficiency (B) Transformer will operate with high efficiency (C) No effect (D) Transformer may start to smoke and burn 

Answer : What will happen if the primary of a transformer is connected to D.C. supply?  (A) Transformer will operate with low efficiency (B) Transformer will operate with high efficiency (C) No effect (D) Transformer may start to smoke and burn 

← Prev Question Next Question →
editChoose topic
...