A Buchholz relay can be installed on oil cooled transformers.

thumb_up_alt 0 like thumb_down_alt 0 dislike

Related questions

Description : Buchholz relay is  (1) located in the conservator tank  (2) located in the transformer tank itself  (3) connected in the pipe connecting main tank of transformer and conservator  (4) installed in the circuit breaker

Answer : Buchholz relay is connected in the pipe connecting main tank of transformer and conservator 

Description : Buchholz relay is used as a safety device with respect to which of the following? A) Audio transformers B) Oil filled power transformers C) Air core transformer D) None of these

Answer : Buchholz relay is used as a safety device with respect to which of the following? A) Audio transformers B) Oil filled power transformers C) Air core transformer D) None of these

Description : What is the use of Buchholz relay in transformer?

Answer : This is a transformer that is used to step up and down current. 

Answer : Buchholz's relay gives warning and protection against electrical fault inside the transformer itself.

Answer : The under voltage relay can be used for generators, busbars, transformers, motors.

Answer : Reactance relay is preferred for phase fault on short transmission line.

Description : main parts of Relay

Answer : Coil, plunger, contacts, springs, connecting terminals and enclosure.

Description : What is phase failure relay and how it's work?

Description : The purpose of the restraining coil in a biased differential relay is  (A) To reduce CT saturation during fault.  (B) To increase the sensitivity of the relay.  (C) To match the transformation ratio.  (D) To limit the spill current through the relay during heavy external fault.

Answer : d

Description : A relay used for protection of motors against overload is :  (A) Impedance relay (B) Electromagnetic attraction type (C) Thermal relay (D) Buchholz's relay

Answer : A relay used for protection of motors against overload is : Thermal relay

Description : A relay has a rating of 5 A, 2.2 sec IDMT and a relay setting of 125% TMS = 0.6. It is connected to a supply circuit through a C.T. 400/5 ratio. The fault current is 4000 A. The operating current of the relay is

Answer : A relay has a rating of 5 A, 2.2 sec IDMT and a relay setting of 125% TMS = 0.6. It is connected to a supply circuit through a C.T. 400/5 ratio. The fault current is 4000 A. The operating current of the relay is 6.25A

Description : The operating time of instantaneous relay is

Answer : The operating time of instantaneous relay is 0.1 sec

Description : What is the difference between relay and contactor?

Answer : Relay have smaller ratings. Contactor is a high rating relay.

Description : A negative sequence relay is used for protection of  (1) Generator (3) Motor (2) Transformer (4) Long Transmission lines

Answer : A negative sequence relay is used for protection of Generator 

Description : To prevent mal-operation of differentially connected relay while energizing a transformer, the relay restraining coil is based with  (1) second harmonic current  (2) third harmonic current  (3) fifth harmonic current  (4) seventh harmonic current

Answer : To prevent mal-operation of differentially connected relay while energizing a transformer, the relay restraining coil is based with  second harmonic current 

Description : Reactance relay is normally preferred for protection against

Answer : Reactance relay is normally preferred for protection against earth faults

Description : In the induction type directional over current relay, when a short-circuit occurs in the circuit (A) power flows in reverse direction (B) power flows in normal direction (C) directional power element does not operate (D) over current element is not energized

Answer : In the induction type directional over current relay, when a short-circuit occurs in the circuit power flows in reverse direction

Description : A solid state relay (A) withstands voltage transients (B) does not require auxiliary dc supply (C) provide low burden on CT and P (D) does not provide earth fault protection

Answer : A solid state relay provide low burden on CT and P

Description : A reactance relay is (A) Voltage restrained directional relay (B) Directional restrained over-current relay (C) Voltage restrained over current relay (D) Directional restrained over voltage relay

Answer : A reactance relay is Directional restrained over-current relay

Answer : The torque produced in induction type relay (shaded pole structure) is inversely proportional to the square of the current.

Answer : Admittance relay is directional relay.

Answer : The relay with inverse time characteristic will operate within 5 to 10 sec.

Answer : Induction cup relay is operated due to changes in current, voltage, impedance.

Answer : Interruption of large currents by relay requires arc suppressing blow out coils, wide separation of the opened contacts, high speed opening of contacts.

Answer : Overheating of relay contacts or contact born out is due to slow making and breaking of load circuit contacts, foreign matter on the contact surface, too low contact pressure.

Answer : A differential relay measures the vector difference between two or more similar electrical quantities.

Answer : Burden of a protective relay is the power absorbed by the circuit of relay.

Answer : In order that current should flow without causing excessive heating or voltage drop, the relay contacts should have low contact resistance, be clean and smooth, be of sufficient size and proper shape.

Answer : The relay operating speed depends upon the spring tension, the rate of flux built up, armature core air gap.

Description : How do relay works ?

Answer : Relay working like contact it is noise less 

Description : What is the difference between a switch and a relay?

Answer : Switch is simply a mechanical contact mechanism and relay is a electromagnetic switch . Switch can be direct mechanically turn on and off but relay can be operated by energising coil .

Description : what is reverse power relay?

Answer : Thereverse powerrelay is a directional protective relay that prevents power from flowing in the reverse direction. Read our article going back ... it all to be up to date. And if you do, read it anyway just to check if youreallydo!

Description : Describe the construction and Operation of Buchholz relay with neat labeled diagram.

Answer : Construction of Buchholz Relay: It takes the form of a domed vessel placed in the connecting pipe between the main tank and the conservator. The device has two elements. The upper element ... manner that it senses the sudden violent movement of oil/gas from transformer tank to conservator. 

Description : Explain Buchholz relay with neat labelled diagram.

Answer : Buchholz relay: The relay is located in the path of the oil from transformer tank to conservator. As seen from diagram, the upper mercury switch operates the alarm circuit due to tilting of the ... manner that it senses the sudden violent movement of oil from transformer tank to conservator.

Description : A Buchholz relay is used for:  A) Protection of a transformer against all internal faults B) Protection of a transformer against external faults C) Protection of a transformer against both internal and external faults D) Protection of instrument transformers and bus bars 

Answer : The buchholz relay is one type of relay which is used in the oil filled power transformerand is for the safety device .

Description : Three phase step-up transformer installed at power house, just before commencement of transmission line, have:

Answer : Three phase step-up transformer installed at power house, just before commencement of transmission line, have: star delta connections

Description : 1. Which Act gave representation to Indians for the first time in the Legislature? 2. By which can the location and energy of an electron in an atom be specified? 3. What was the ... set of mansoon & are harvested in September-October? 20. Which philosophical system was founded by Vallabhacharya?

Answer : Answer : 1. Government of India Act, 1935 2. Quantum numbers 3. Balwant Rai Mehta 4. Pine 5. Bamiyan 6. Mother Teresa 7. Number of WBCs increases in blood 8. Prime Minister 9. Equatorial ... -bin-Tughlaq 16. By combining various foods 17. Constitution of India 18. Xenon 19. Kharif 20. Suddhadvaita

Answer : Helical coils can be used on low voltage side of high kVA transformers.

Description : Which three-phase connection can be used in a transformer to introduce a phase difference of 30o between its output and corresponding input line voltages  (A) Star-Star (B) Star-Delta (C) Delta-Delta (D) Delta-Zigzag

Answer : Which three-phase connection can be used in a transformer to introduce a phase difference of 30o between its output and corresponding input line voltages  (A) Star-Star (B) Star-Delta (C) Delta-Delta (D) Delta-Zigzag

Answer : Iron loss of a transformer can be measured by low power factor wattmeter.

Description : The efficiency of two identical transformers under load conditions can be determined by?

Answer : The efficiency of two identical transformers under load conditions can be determined by back-to-back test.

Description : A round viewing window with a 20 centimeter diameter is installed in a tank at the Shedd Aquarium. It is 5 meters below the water surface. The force on the window is approximately: w) 1,500 Newtons x) 10,000 Newtons y) 25,000 Newtons z) 50,000 Newtons

Answer : ANSWER: W -- 1,500 NEWTONS

Description : If a self excited d.c. generator after being installed, fails to build up voltage on its first trial run, the first thing to do is (a) reverse the field winding connections (b) increase the field resistance (c) decrease the speed of prime mover (d) increase the speed of prime mover  

Description : Imagine a possibility of an emergency evacuation scenario in a domestic household in India. The height at which the inside latch of the exit-door should be installed is to be finalised. It is required to ... in the family. D. The average height of the tallest adult male and tallest adult female.

Answer : B

Answer : For high value of diversity factor, a power station of given installed capacity will be in a position to supply more number of consumers.

Description : By burden on the relay, we generally mean   (a) Current rating of relay (b) Voltage rating of relay (c) Volt-ampere rating of relay (d) Watt rating of relay 

Description : For a traction transformer circuit breaker state: 1) Rated current and rupturing capacity 2) Any two tests it should be capable of withstanding 3) Overall tripping time and relay time.

Answer : Ans: 1) Rated current --- 750 A and Rupturing capacity --- 500 MVA  2) Any two tests it should be capable of withstanding --- Breaking test , Reclosing test , Endurance test ( any two )  3) Overall tripping time --- 0.14 sec and Relay time --- 0.04 sec 