menu search
person
thumb_up_alt 0 like thumb_down_alt 0 dislike
105 views

1 Answer

Distribution transformers are generally designed for maximum efficiency around 50% load.

thumb_up_alt 0 like thumb_down_alt 0 dislike
← Prev Question Next Question →

Related questions

Description :

Answer :

Power transformers are generally designed to have maximum efficiency around near full-load.

thumb_up_alt 0 like thumb_down_alt 0 dislike
80 views 1 answer
Description :

Answer :

Natural air cooling is generally restricted for transformers up to 1.5 MVA .

thumb_up_alt 0 like thumb_down_alt 0 dislike
152 views 1 answer
Description :

The efficiency of two identical transformers under load conditions can be determined by?

Answer :

The efficiency of two identical transformers under load conditions can be determined by back-to-back test.

thumb_up_alt 0 like thumb_down_alt 0 dislike
151 views 1 answer
thumb_up_alt 0 like thumb_down_alt 0 dislike
109 views 2 answers
Description :

If the percentage impedances of the two transformers working in parallel are different, then?

Answer :

If the percentage impedances of the two transformers working in parallel are different, then parallel operation will still be possible, but the power factors at which the two transformers operate will be different from the power factor of the common load.

thumb_up_alt 0 like thumb_down_alt 0 dislike
77 views 1 answer
Description :

Losses which occur in rotating electric machines and do not occur in transformers are?

Answer :

Friction losses windage losses 

thumb_up_alt 0 like thumb_down_alt 0 dislike
125 views 2 answers
Description :

The efficiencies of transformers compared with that of electric motors of the same power are?

Answer :

Transformers have high efficiency than the same ratted motors

thumb_up_alt 0 like thumb_down_alt 0 dislike
113 views 2 answers
Description :

Answer :

Natural oil cooling is used for transformers up to a rating of 3000 kVA.

thumb_up_alt 0 like thumb_down_alt 0 dislike
138 views 1 answer
Description :

Answer :

Necessary conditions required to be satisfied in order to ensure successful parallel operation of single phase transformers:  1. Only transformers having the same phase displacement between primary and secondary ... . 7. The phase sequence must be followed strictly on HV and LV side connection.

thumb_up_alt 0 like thumb_down_alt 0 dislike
124 views 2 answers
Description :

Answer :

D.C. generators are normally designed for maximum efficiency around full-load.

thumb_up_alt 0 like thumb_down_alt 0 dislike
79 views 1 answer
Description :

Two transformers are connected in parallel. These transformers do not have equal percentage impedance. This is likely to result in?

Answer :

Two transformers are connected in parallel. These transformers do not have equal percentage impedance. This is likely to result in loading of the transformers not in proportion to their kVA ratings.

thumb_up_alt 0 like thumb_down_alt 0 dislike
107 views 1 answer
Description :

Answer :

Short circuit test on transformers is conducted to determine copper losses.

thumb_up_alt 0 like thumb_down_alt 0 dislike
134 views 1 answer
Description :

Core type transformers are popular in___________.  (A) High voltage applications (B) Low voltage applications (C) All of the above (D) None of the above

Answer :

Core type transformers are popular in High voltage applications

thumb_up_alt 0 like thumb_down_alt 0 dislike
71 views 1 answer
Description :

In a transmission line if booster transformers are to be used, preferred location will be  (A) At the receiving end (B) At the sending end (C) At the intermediate point (D) Anywhere in the line 

Answer :

In a transmission line if booster transformers are to be used, preferred location will be At the intermediate point

thumb_up_alt 0 like thumb_down_alt 0 dislike
252 views 1 answer
Description :

The friction losses in Real Transformers are :  (A) 0% (B) 5% (C) 25% (D) 50%

Answer :

A

thumb_up_alt 0 like thumb_down_alt 0 dislike
3.1k views 2 answers
Description :

Answer :

Instrument transformers are potential transformers, current transformers.

thumb_up_alt 0 like thumb_down_alt 0 dislike
64 views 1 answer
Description :

Answer :

Current transformers (CT) : Current transformer (CT) actually step down the high current to low current for the operation of relays. Current transformer is use for measurement of ... use for relay. This is about potential transformer.

thumb_up_alt 1 like thumb_down_alt 1 dislike
122 views 1 answer
Description :

An additional condition for parallel operation of three-phase transformers over single-phase transformers is that

Answer :

An additional condition for parallel operation of three-phase transformers over single-phase transformers is that the transformers should belong to the same vector group

thumb_up_alt 0 like thumb_down_alt 0 dislike
100 views 1 answer
Description :

Answer :

The maximum efficiency of a distribution transformer is at 50% full load.

thumb_up_alt 0 like thumb_down_alt 0 dislike
74 views 1 answer
Description :

Classify the transformers based on the construction, frequency and power.

Answer :

Classification of Transformer Based On: i) Construction: Shell type, Core type, Berry type ii) Change in voltage level: Step-Up, Step-Down, iii) Number of phases: Single phase, Three phase iv) ... Control vi) Cooling: Self-cooled, Air-cooled, Forced-air cooled, Oil-cooled, Forced-oil cooled. 

thumb_up_alt 0 like thumb_down_alt 0 dislike
113 views 1 answer
Description :

Which of the following connection of transformers will give highest value of secondary voltage ? (A) Delta primary delta secondary (B) Delta primary star secondary (C) Star primary star secondary (D) Star primary delta secondary

Answer :

Which of the following connection of transformers will give highest value of secondary voltage ? (A) Delta primary delta secondary (B) Delta primary star secondary (C) Star primary star secondary (D) Star primary delta secondary

thumb_up_alt 0 like thumb_down_alt 0 dislike
159 views 1 answer
Description :

Two transformers A and B having equal outputs and voltage ratios but unequal percentage impedances of 4 and 2 are operating in parallel. The transformer A will be overloaded by 

Answer :

Two transformers A and B having equal outputs and voltage ratios but unequal percentage impedances of 4 and 2 are operating in parallel. The transformer A will be overloaded by 33%

thumb_up_alt 0 like thumb_down_alt 0 dislike
291 views 1 answer
Description :

Two 3-phase transformers cannot be operated in parallel, if their :  (A) kVAs are different (B) phase sequences are different (C) % impedances are different (D) voltage ratios are different

Answer :

Two 3-phase transformers cannot be operated in parallel, if their : phase sequences are different

thumb_up_alt 0 like thumb_down_alt 0 dislike
54 views 1 answer
Description :

Which of the following is the advantage of using CRGO steel in transformers? A) High magnetic flux density B) Low permeability C) Both A and B D) None of these

Answer :

It definitely High Magnetic Flux Density since a crgo steel has always a more around 3% of silicon proportion among the remaining ferrite which make cold rolled grain oriented steel having high flux magnetic ... for more about the crgo core you can learn here https://nicoreindia.com/crgo-core/

thumb_up_alt 0 like thumb_down_alt 0 dislike
95 views 2 answers
Description :

What is the back EMF in Transformers?

thumb_up_alt 0 like thumb_down_alt 0 dislike
70 views 0 answers
Description :

Why do transformers make noise?

Answer :

Transformers make noise based on it out put if an transformer outputs is 400v maximum than a 398v be apply to that transformer it also make a noise because of that 

thumb_up_alt 1 like thumb_down_alt 0 dislike
78 views 1 answer
Description :

Answer :

Generators for peak load plants are usually designed for maximum efficiency at 50 to 75 percent full load.

thumb_up_alt 0 like thumb_down_alt 0 dislike
93 views 1 answer
Description :

Define: (i) Commercial efficiency of a transformer and  (ii) All day efficiency of a transformer.

Answer :

(i) Commercial Efficiency : It is the ratio of output power in watt to the input power in watt. (ii) All day efficiency of a transformer: It is the ratio of output energy in kWh to the input energy in kWh in the 24 hours of the day

thumb_up_alt 0 like thumb_down_alt 0 dislike
19 views 1 answer
Description :

Answer :

A common method of cooling a power transformer is oil cooling.

thumb_up_alt 0 like thumb_down_alt 0 dislike
104 views 1 answer
Description :

Answer :

Harmonics in transformer result in increased core losses, increased I2R losses, and magnetic interference with communication circuits.

thumb_up_alt 0 like thumb_down_alt 0 dislike
54 views 1 answer
Description :

Distribution transformers have good all day efficiency due to  (A) low copper loss (B) low iron loss (C) low copper and iron loss (D) None of these

Answer :

Distribution transformers have good all day efficiency due to low iron loss

thumb_up_alt 0 like thumb_down_alt 0 dislike
63 views 1 answer
Description :

For a constant load current, transformer maximum efficiency occurs at   (a) any power factor (b) zero power factor leading (c) zero power factor lagging (d) unity power factor 

Answer :

For a constant load current, transformer maximum efficiency occurs at unity power factor 

thumb_up_alt 0 like thumb_down_alt 0 dislike
233 views 1 answer
Description :

For a transformer, operating at constant load current, maximum efficiency will occur at?

Answer :

For a transformer, operating at constant load current, maximum efficiency will occur at unity power factor.

thumb_up_alt 0 like thumb_down_alt 0 dislike
97 views 1 answer
Description :

State any two conditions for parallel operation of 3-phase transformer.

Answer :

Conditions for Parallel operation of 3 phase transformer 1) Voltage ratings of both the transformers must be identical. 2) Percentage or p.u. impedance should be equal in magnitude. 3) X/R ratio ... between primary & secondary voltages must be same. 6) Phase sequence on both sides must be same.

thumb_up_alt 0 like thumb_down_alt 0 dislike
17 views 1 answer
Description :

A simple phase transformer has a maximum efficiency of 90% at full load and unity power factor. Efficiency at half load at the same power factor is  (A) 86.7% (B) 88.26% (C) 88.9% (D) 87.8%

Answer :

A simple phase transformer has a maximum efficiency of 90% at full load and unity power factor. Efficiency at half load at the same power factor is 87.8%

thumb_up_alt 0 like thumb_down_alt 0 dislike
511 views 1 answer
Description :

Answer :

An ideal transformer will have maximum efficiency at a load such that copper loss equal to iron loss.

thumb_up_alt 0 like thumb_down_alt 0 dislike
107 views 1 answer
Description :

Instruments transformers are used on a.c. circuits for extending the range of (a) ammeters (b) voltmeters (c) wattmeters (d) all of these 

Answer :

ammeter

thumb_up_alt 0 like thumb_down_alt 0 dislike
335 views 2 answers
Description :

In general AC distribution systems, arc interruption in vacuum circuit breakers are designed to function in a time period of (a) One cycle (b) Two to three cycles (c) Within ten cycles (d) None of the above

Answer :

In general AC distribution systems, arc interruption in vacuum circuit breakers are designed to function in a time period of One cycle

thumb_up_alt 0 like thumb_down_alt 0 dislike
129 views 1 answer
Description :

Control systems are generally designed with damping  a) less than one  b) greater than one c) equal to one d) with any value depending upon system requirement

Answer :

Control systems are generally designed with damping  less than one 

thumb_up_alt 0 like thumb_down_alt 0 dislike
37 views 1 answer
Description :

State any two applications of single phase autotransformer.

Answer :

Applications of single phase auto transformers: 1) Give small boost to distribution cable to correct the voltage drop. 2) As auto transformer starter for induction motors. 3) As furnace supply ... . 5) In control equipment for single phase locomotives. 6) As dimmer in lighting circuits.

thumb_up_alt 0 like thumb_down_alt 0 dislike
12 views 1 answer
Description :

Compare core type transformer and shell type transformer on the following parameters. (i) Types of winding used, (ii) Application

Answer :

Ans:

thumb_up_alt 0 like thumb_down_alt 0 dislike
11 views 1 answer
Description :

Define transformation ratio in terms of current and voltage.

Answer :

(i) Transformation Ratio (K) is defined as the ratio of the primary current to the secondary current.  (ii) Transformation Ratio (K) is defined as the ratio of the secondary voltage to the primary voltage.

thumb_up_alt 0 like thumb_down_alt 0 dislike
12 views 1 answer
Description :

A 50 KVA transformer has iron loss 2 kW on full load. Calculate its iron loss at 75% of full load.

Answer :

Iron loss is dependent on voltage and independent of load. Hence iron loss at 75% of Load = Iron loss at full load = 2 kW

thumb_up_alt 0 like thumb_down_alt 0 dislike
24 views 1 answer
Description :

State any four properties of Ideal transformer.

Answer :

Properties of Ideal transformer: 1) No losses (iron and copper losses), hence no temperature rise. 2) No magnetic leakage i.e (Coefficient of coupling between primary and secondary windings is unity) 3) Zero winding ... drop i.e. E1 = V1, E2 = V2 5) Efficiency 100 %. 6) Regulation 0 %.

thumb_up_alt 0 like thumb_down_alt 0 dislike
12 views 1 answer
Description :

Draw the connection diagram of long shunt differential D.C. compound generator.

Answer :

Ans:

thumb_up_alt 0 like thumb_down_alt 0 dislike
10 views 1 answer
thumb_up_alt 0 like thumb_down_alt 0 dislike
2.5k views 0 answers
Description :

Why circuit breaker connect b)w two transformer  (same rating

Answer :

Because two transformers connection is in parallel to share the load if any transformer is receives the surge current because of the fault so to protect the other transformer from the fault. 

thumb_up_alt 0 like thumb_down_alt 0 dislike
101 views 1 answer
Description :

Answer :

In case the conditions for maximum power for a D.C. motor are established, the efficiency of the motor will be less than 50%.

thumb_up_alt 0 like thumb_down_alt 0 dislike
122 views 1 answer
Description :

Two transformers with identical voltage ratings are working in parallel to supply common load. The percentage impedance of one transformer is higher compared to that of other. The load sharing between the two transformer will: (1) Be proportional to their percentage impedance (2) Be independent of their percentage impedance (3) Be inversely proportional of their respective impedance (4) Depend on the resistance to leakage reactance ratio of each transformer

Answer :

Two transformers with identical voltage ratings are working in parallel to supply common load. The percentage impedance of one transformer is higher compared to that of other. The load sharing between the two transformer will: Be inversely proportional of their respective impedance

thumb_up_alt 0 like thumb_down_alt 0 dislike
52 views 1 answer
editAsk a Question
...