When secondary of a current transformer is open-circuited its iron core will be?

1 Answer

When secondary of a current transformer is open-circuited its iron core will be hot because of heavy iron losses taking place in it due to high flux density.

thumb_up_alt 0 like thumb_down_alt 0 dislike

Related questions

Description : The secondary of a current transformer is always short-circuited under operating conditions because it?

Answer : The secondary of a current transformer is always short-circuited under operating conditions because it avoids core saturation and high voltage induction.

Description : A ferrite core has less eddy current loss than an iron core because?

Answer : A ferrite core has less eddy current loss than an iron core because ferrites have high hysteresis.

Description : In a transformer the resistance between its primary and secondary should be?

Answer : In a transformer the resistance between its primary and secondary should be infinity.

Description : The size of a transformer core will depend on?

Answer : The size of a transformer core will depend on frequency and area of the core.

Answer : If the supply frequency to the transformer is increased, the iron loss will increase.

Answer : Iron loss of a transformer can be measured by low power factor wattmeter.

Description : State any four characteristics of core type transformer.

Answer : Characteristics of core type transformer: i) It has one window. ii) It has one magnetic circuit. iii) Core surrounds the winding. iv) Average length of core is more. v) Area of cross ... Better cooling for winding. vii) Mechnical strength is comparatively less. viii) Repair and maintenance is easy.

Answer : Material used for construction of transformer core is usually silicon steel.

Description : Reduction in core losses and increase in permeability are obtained with transformer employing?

Answer : Reduction in core losses and increase in permeability are obtained with transformer employing core built-up of laminations of cold rolled grain oriented steel.

Answer : In an actual transformer the iron loss remains practically constant from no load to full load because core flux remains practically constant.

Description : Increasing the number of turns of wire on the secondary of a transformer will  (A) Decrease the secondary current (B) Increase the primary current (C) Have no effect on the secondary current (D) Increase the secondary current

Answer : Increasing the number of turns of wire on the secondary of a transformer will Decrease the secondary current 

Answer : When a conductor carries more current on the surface as compared to core, it is due to skin effect.

Description : Why does the core of a transformer need to be laminated?

Answer : Transformer cores are laminated to reduce eddy current loss.

Description : Eddy current damping cannot be used for moving iron instrument because

Answer : Eddy current damping cannot be used for moving iron instrument because the presence of a permanent magnet required for such purpose would affect the deflection and hence the reading of the instrument

Description : A certain transformer has 200 turns in the primary winding, 50 turns in the secondary winding and 120 volts applied to the primary. What is the voltage across the secondary?  (A) 30 Volts (B) 480 Volts (C) 120 Volts (D) 60 Volts

Answer : A certain transformer has 200 turns in the primary winding, 50 turns in the secondary winding and 120 volts applied to the primary. What is the voltage across the secondary?  (A) 30 Volts (B) 480 Volts (C) 120 Volts (D) 60 Volts

Description : For a transformer, operating at constant load current, maximum efficiency will occur at?

Answer : For a transformer, operating at constant load current, maximum efficiency will occur at unity power factor.

Description : A 40 kVA transformer has a core loss of 400 W and a full load copper loss of 800 W. The proportion of full load at maximum efficiency is

Answer : A 40 kVA transformer has a core loss of 400 W and a full load copper loss of 800 W. The proportion of full load at maximum efficiency is 0.707

Description : The core construction is like spokes of a wheel in following transformer:  (A) Berry Type Transformer (B) Core Type Transformer (C) Shell Type Transformer (D) None of the above

Answer : The core construction is like spokes of a wheel in following transformer:  Berry Type Transformer

Description : The desirable properties of transformer core material are  (1) low permeability and low hysteresis loss. (2) high permeability and high hysteresis loss. (3) high permeability and low hysteresis loss. (4) low permeability and hysteresis loss.

Answer : The desirable properties of transformer core material are high permeability and low hysteresis loss.

Description : The main purpose of using core in a transformer is to (A) decrease iron losses (B) eliminate magnetic hysteresis (C) reduce reluctance of the common magnetic circuit (D) prevent eddy current loss

Answer : Reduce Relucatnce of the common magnetic circuit.

Answer : Transformer core is laminated to reduce Eddy current losses.

Description : At full -load of a transformer, the iron loss and copper loss are 3000 W and 4000 W respectively. Then total loss at maximum efficiency is :  (A) 7000 W (B) 6000 W (C) 8000 W (D) 4000 W

Answer : At full -load of a transformer, the iron loss and copper loss are 3000 W and 4000 W respectively. Then total loss at maximum efficiency is : 6000 W

Description : Even at no-load, a transformer draws current from the mains. Why?

Description : In a step-down transformer, there is a change of 15 A in the load current. This results in change of supply current of?

Answer : In a step-down transformer, there is a change of 15 A in the load current. This results in change of supply current of less than 15A.

Description : If an unsymmetrical line to ground fault occurs at the secondary terminals of a delta/star, ungrounded transformer, then  (A) zero sequence currents are present on both sides of the transformer  (B) ... side  (D) zero sequence currents are present on the primary side but not on the secondary side

Answer : If an unsymmetrical line to ground fault occurs at the secondary terminals of a delta/star, ungrounded transformer, then zero sequence currents are absent on both sides of the transformer 

Answer : The purpose of providing an iron core in a transformer is to decrease the reluctance of the magnetic path.

Answer : The purpose of providing iron core in a step-up transformer is to decrease the magnitude of magnetizing current.

Description : The operating point of a protective current transformer is near the

Answer : The operating point of a protective current transformer is near the Ankle point

Description : Step-down transformer converts high voltage and low current into:  (A) How voltage and high current (B) High voltage and low current (C) Low voltage and high current (D) None of the above

Answer : Step-down transformer converts high voltage and low current into: Low voltage and high current

Description : The inrush current of a transformer at no load is maximum if the supply voltage is switched on  (1) at peak voltage value (2) at zero voltage value (3) at half voltage value (4) at 0.866 time voltage value

Answer : At 0.866 time voltage value

Description : In a single-phase transformer, the magnetizing current is (A) in phase with the no-load current (B) in quadrature with the no-load current (C) the product of no-load current and power factor (D) in phase with the flux in the core

Answer : In a single-phase transformer, the magnetizing current is in phase with the flux in the core

Answer : The inverse definite mean time relays are used for over current and earth fault protection of transformer against internal short-circuits.

Description : How eddy current is produced in a transformer?

Description : Why CT is never operated with an open secondary ?

Answer : CT secondary should never be kept open because it will cause saturation of the core to a high level and very high voltage will appear across the secondary which can breakdown the insulation. One terminal of PT secondary is always grounded to avoid capacitive induction and for human safety

Answer : An ideal transformer has infinite values of primary and secondary inductances. The statement is false.

Description : Which of the following connection of transformers will give highest value of secondary voltage ? (A) Delta primary delta secondary (B) Delta primary star secondary (C) Star primary star secondary (D) Star primary delta secondary

Answer : Which of the following connection of transformers will give highest value of secondary voltage ? (A) Delta primary delta secondary (B) Delta primary star secondary (C) Star primary star secondary (D) Star primary delta secondary

Answer : The core used in high frequency transformer is usually air core .

Description : Select insulating materials for following parts : (i) Insulation between heating element and base plate of electric iron. (ii) Insulation used over copper or aluminium conductor used for making coils. (iii) Transformer bushings. (iv) Insulation between transmission line and pole.

Answer : Parts Insulating Materials  Insulation between heating element and base plate of electric iron. Mica Insulation used over copper or aluminium conductor used for making coils.  ... Transformer bushings Porcelain  Insulation between transmission line and pole. Porcelain

Description : What happens to the voltage in the secondary when the frequency of the supply in the primary is decreased? A) It increases B) It decreases C) It remains the same D) Cannot say unless the actual percentage increase in the frequency is known

Answer : What happens to the voltage in the secondary when the frequency of the supply in the primary is decreased? A) It increases B) It decreases C) It remains the same D) Cannot say unless the actual percentage increase in the frequency is known

Answer : When a given transformer is run at its rated voltage but reduced frequency, its core flux density is increased.

Description : During open circuit test of a transformer?

Answer : During open circuit test of a transformer primary is supplied rated voltage.

Description : An open-circuit test on a transformer is conducted primarily to measure?

Answer : The open-circuit test in a transformer is used to measure

Answer : The full-load copper loss of a trans¬former is 1600 W. At half-load, the copper loss will be 400 W.

Description : What to look for when choosing an iron?

Answer : What to look for when choosing an iron? Today, the purchase of an iron is not a big problem. This piece of household appliances is presented in a wide range of stores. Each manufacturer tries to ... its presence increases the cost of the iron by an average of 10%. Good luck with your choice!

Description : For a pulse transformer, the material used for its core and the possible turn ration from primary to secondary are respectively   (A) ferrite : 20 : 1 (B) laminated iron : 1 :1 (C) ferrite : 1 : 1 (D) powered iron : 1: 1

Answer : For a pulse transformer, the material used for its core and the possible turn ration from primary to secondary are respectively ferrite : 1 : 1

Answer : A moving iron instrument can be used for both D.C. and A.C.

Answer : No-load current in a transformer lags behind the voltage by about 75°.

Answer : The no load current in a transformer lags behind the applied voltage by an angle of about 75°.

Answer : No-load current of a transformer has small magnitude and low power factor.