search
person

1 Answer

Natural air cooling is generally restricted for transformers up to 1.5 MVA .

thumb_up_alt 0 like thumb_down_alt 0 dislike

Related questions

Answer : Natural oil cooling is used for transformers up to a rating of 3000 kVA.

Answer : A common method of cooling a power transformer is oil cooling.

Answer : Distribution transformers are generally designed for maximum efficiency around 50% load.

Answer : Power transformers are generally designed to have maximum efficiency around near full-load.

Answer : Overload capacity of diesel engines is usually restricted to 2 percent.

Answer : The rate of acceleration on suburban or urban services is restricted by the consideration of Passenger Discomfort.

Answer : Necessary conditions required to be satisfied in order to ensure successful parallel operation of single phase transformers:  1. Only transformers having the same phase displacement between primary and secondary ... . 7. The phase sequence must be followed strictly on HV and LV side connection.

Description : Which of the following is used for thermoelectric cooling? A) Peltier effect B) Seebeck effect C) Both A and B D) None of these

Answer : Which of the following is used for thermoelectric cooling? A) Peltier effect B) Seebeck effect C) Both A and B D) None of these

Description : Two transformers are connected in parallel. These transformers do not have equal percentage impedance. This is likely to result in?

Answer : Two transformers are connected in parallel. These transformers do not have equal percentage impedance. This is likely to result in loading of the transformers not in proportion to their kVA ratings.

Answer : Short circuit test on transformers is conducted to determine copper losses.

Description : If the percentage impedances of the two transformers working in parallel are different, then?

Answer : If the percentage impedances of the two transformers working in parallel are different, then parallel operation will still be possible, but the power factors at which the two transformers operate will be different from the power factor of the common load.

Description : Losses which occur in rotating electric machines and do not occur in transformers are?

Answer : Friction losses windage losses 

Description : The efficiency of two identical transformers under load conditions can be determined by?

Answer : The efficiency of two identical transformers under load conditions can be determined by back-to-back test.

Description : The efficiencies of transformers compared with that of electric motors of the same power are?

Answer : Transformers have high efficiency than the same ratted motors

Description : Draw and explain the function of cooling tower in TPS.

Answer : Cooling tower in TPS: The function of cooling tower is to reduce the temperature of water coming from condenser. Water is circulated from the basin of the cooling ... cooling Tower temperature of water is reduced either by natural or forced or induced draught method or combine

Description : State the function of cooling tower and condenser in thermal power station.

Answer : 1. Condenser:   Function of condenser is to convert exhaust steam again into water by reducing its temperature with the help of cold water. Also it reduces back pressure of steam turbine 2 ... tower : The function of cooling tower is to reduce the temperature of water coming from condenser.

Description : How to choose high quality and natural dairy products?

Answer : Dairy products have always been the basis of nutrition, and this is quite justified: after all, they contain only natural substances that contribute to normal digestion. However, in an effort to reduce ... kilogram. Real sour cream will only be called sour cream, and butter will be called butter.

Description : An accelerometer has input range of 0 to 10g, natural frequency 30 Hz and mass 0.001 kg. The range of the secondary displacement transducer in mm required to cover the input range is (A) 0 to 2.76 (B) 0 to 9.81 (C) 0 to 11.20 (D) 0 to 52.10

Answer : An accelerometer has input range of 0 to 10g, natural frequency 30 Hz and mass 0.001 kg. The range of the secondary displacement transducer in mm required to cover the input range is 0 to 2.76

Description : Differentiate between Natural and Forced commutation

Answer : Natural commutation Forced commutation Source is AC Source is DC External commutating componants are not required  External commutating componants are required SCR turns off ... in controlled rectifiers, AC voltage controllers etc.  Used in choppers & inverters etc

Description : Define natural, mechanical, forced and induced draught systems.

Answer : Natural draught system: - When the fuel is burnt (combustion) in the furnace due to natural circulation of air, the draught is called natural draught. Mechanical draught system: -  In a mechanical ... combustion. OR If fan/blower is placed after the furnace then it is called as induced draught

Answer : Natural commutation is also called as line Communication. The turning off of thyristor due to AC supply is called natural commutation or line commutation. If the thyristor is connected to AC supply ... connected to positive and anode terminal get connected to negative, this turns off the thyristor.

Answer : Air blast circuit breakers for 400 kV power system are designed to operate in 50 millisecond.

Description : An additional condition for parallel operation of three-phase transformers over single-phase transformers is that

Answer : An additional condition for parallel operation of three-phase transformers over single-phase transformers is that the transformers should belong to the same vector group

Description : What is an air ionizer for?

Answer : In recent years, air ionizers have become more and more popular in the household appliances market . And this is quite justified, because their use can significantly improve air quality and minimize the ... advice and, together with a doctor, decide on the possibility of further use of the device.

Answer : Air blast circuit breaker is used for repeated duty.

Description : In a transmission line if booster transformers are to be used, preferred location will be  (A) At the receiving end (B) At the sending end (C) At the intermediate point (D) Anywhere in the line 

Answer : In a transmission line if booster transformers are to be used, preferred location will be At the intermediate point

Description : Wall-mounted air conditioners: what to consider when choosing?

Answer : Home and office climatic equipment in practice is mainly represented by wall-mounted air conditioners or split systems. The variety of design of split-systems allows not only to successfully fit ... are the famous Japanese brands Daikin, Mitsubishi Electric, Toshiba, General, Fujitsu and Panasonic.

Description : Why is it necessary to keep air gaps in magnetic circuits as small as possible?

Description : What happens to the capacitance if mica is inserted between the plates of an air capacitor? A) The capacitance increases B) The capacitance decreases C) The capacitance remains the same D) The capacitance becomes zero

Answer : What happens to the capacitance if mica is inserted between the plates of an air capacitor? A) The capacitance increases B) The capacitance decreases C) The capacitance remains the same D) The capacitance becomes zero

Description : An air gap is usually inserted in magnetic circuits to?

Answer : An air gap is usually inserted in magnetic circuits to prevent saturation.

Description : Classify the transformers based on the construction, frequency and power.

Answer : Classification of Transformer Based On: i) Construction: Shell type, Core type, Berry type ii) Change in voltage level: Step-Up, Step-Down, iii) Number of phases: Single phase, Three phase iv) ... Control vi) Cooling: Self-cooled, Air-cooled, Forced-air cooled, Oil-cooled, Forced-oil cooled. 

Description : Which of the following connection of transformers will give highest value of secondary voltage ? (A) Delta primary delta secondary (B) Delta primary star secondary (C) Star primary star secondary (D) Star primary delta secondary

Answer : Which of the following connection of transformers will give highest value of secondary voltage ? (A) Delta primary delta secondary (B) Delta primary star secondary (C) Star primary star secondary (D) Star primary delta secondary

Description : Two transformers A and B having equal outputs and voltage ratios but unequal percentage impedances of 4 and 2 are operating in parallel. The transformer A will be overloaded by 

Answer : Two transformers A and B having equal outputs and voltage ratios but unequal percentage impedances of 4 and 2 are operating in parallel. The transformer A will be overloaded by 33%

Description : Core type transformers are popular in___________.  (A) High voltage applications (B) Low voltage applications (C) All of the above (D) None of the above

Answer : Core type transformers are popular in High voltage applications

Description : The friction losses in Real Transformers are :  (A) 0% (B) 5% (C) 25% (D) 50%

Answer : A

Description : Two 3-phase transformers cannot be operated in parallel, if their :  (A) kVAs are different (B) phase sequences are different (C) % impedances are different (D) voltage ratios are different

Answer : Two 3-phase transformers cannot be operated in parallel, if their : phase sequences are different

Description : Which of the following is the advantage of using CRGO steel in transformers? A) High magnetic flux density B) Low permeability C) Both A and B D) None of these

Answer : It definitely High Magnetic Flux Density since a crgo steel has always a more around 3% of silicon proportion among the remaining ferrite which make cold rolled grain oriented steel having high flux magnetic ... for more about the crgo core you can learn here https://nicoreindia.com/crgo-core/

Answer : Instrument transformers are potential transformers, current transformers.

Description : What is the back EMF in Transformers?

Answer : Current transformers (CT) : Current transformer (CT) actually step down the high current to low current for the operation of relays. Current transformer is use for measurement of ... use for relay. This is about potential transformer.

Description : Why do transformers make noise?

Answer : Transformers make noise based on it out put if an transformer outputs is 400v maximum than a 398v be apply to that transformer it also make a noise because of that 

Description : Compare reciprocating and rotary air compressor

Answer : Reciprocating compressor Rotary compressor  1. Compression of air takes place with help of piston and cylinder arrangement with reciprocating motion of piston. 1. Compression of air takes place ... High 12. More Starting torque required 12. Less Starting torque required

Description : Graph indicating changes in pollutants level w.r.t air fuel ratio

Answer : Graph indicating changes in pollutants level w.r.t air fuel ratio

Description :  applications of compressed air

Answer : 1) To drive air motors in coal mines. 2) To inject fuel in air injection diesel engines. 3) To operate pneumatic drills, hammers, hoists, sand blasters. 4) For cleaning purposes. 5) To cool large ... and farm maintenance. 7) In vehicle to operate air brake. 8) For spray painting in paint industry.

Description : Explain fuel system and air intake system in diesel electric power plant.

Answer : Fuel system and air intake system in diesel electric power plant :  Fuel system: It consists of storage tank, strainers, fuel transfer pump and all day fuel tank. The fuel oil is supplied ... Filters are provided to remove dust particles from air which may act as abrasive in the engine cylinder.

Description : State the functions of following elements: i) Diesel engine system ii) Air intake system iii) Engine exhaust system iv) Engine starting system.

Answer : i) Diesel engine system:-  Four strokes Two strokes ii) Air intake system:- Air intake system is provided to supply air to engine cylinder for fuel combustion.  iii) Engine exhaust system ... provided to rotate the engine initially until the firing starts and engine run under its own power. 

Description : Describe with neat diagram air friction damping. 

Answer : Air Friction Damping: Here air trapped in the chamber works as damping medium for the piston movement connected to the spindle. The piston moves in the air chamber. The clearance between piston and ... will be the damping torque, bringing the pointer to the equilibrium position quickly. 

← Prev Question Next Question →