search
person
In a given transformer for a given applied voltage, losses which remain constant irrespective of load changes are?

1 Answer

In a given transformer for a given applied voltage, losses which remain constant irrespective of load changes are hysteresis and eddy current losses.

thumb_up_alt 0 like thumb_down_alt 0 dislike

Related questions

Description : For a transformer, operating at constant load current, maximum efficiency will occur at?

Answer : For a transformer, operating at constant load current, maximum efficiency will occur at unity power factor.

Answer : In an actual transformer the iron loss remains practically constant from no load to full load because core flux remains practically constant.

Description : The maximum constant load torque under which a synchronous motor will pull into synchronism at rated rotor supply voltage and frequency is known as?

Answer : The maximum constant load torque under which a synchronous motor will pull into synchronism at rated rotor supply voltage and frequency is known as pull-in torque.

Description : A transformer has negative voltage regulation when its load power factor is   (1) Zero (2) Unity (3) Leading (4) Lagging

Answer : Leading

Description : Reduction in core losses and increase in permeability are obtained with transformer employing?

Answer : Reduction in core losses and increase in permeability are obtained with transformer employing core built-up of laminations of cold rolled grain oriented steel.

Description : In a synchronous motor which losses varies with load?

Answer : In a synchronous motor, copper losses varies with load.

Description : In synchronous motor, does the winding losses vary with load?

Answer : No, in the synchronous motor the winding losses do not vary with load.

Description : Explain the electrical losses of magnetic materials used for the cores of inductors and transformer.

Description : A 3 -phase, fully controlled, converter is feeding power into a DC load at a constant current of 150 A, the rms value of the current flowing through each thyristor of the converter is

Answer : A 3 -phase, fully controlled, converter is feeding power into a DC load at a constant current of 150 A, the rms value of the current flowing through each thyristor of the converter is 150/√3

Description : In a step-down transformer, there is a change of 15 A in the load current. This results in change of supply current of?

Answer : In a step-down transformer, there is a change of 15 A in the load current. This results in change of supply current of less than 15A.

Answer : An ideal transformer will have maximum efficiency at a load such that copper loss equal to iron loss.

Description : The maximum load that a power transformer can carry is limited by its?

Answer : The maximum load that a power transformer can carry is limited by its voltage ratio.

Description : Negative voltage regulation is indicative that the load is?

Answer : Negative voltage regulation is indicative that the load is capacitive.

Description : Minimum voltage regulation occurs when the power factor of the load is?

Answer : Minimum voltage regulation occurs when the power factor of the load is leading.

Description : A dc chopper is fed from a constant voltage mains the duty ratio of chopper is progressively increased while the chopper feeds an RL load. The per unit current ripple would  (1) increase progressively  (2 ... 0.5 and then increase  (4) increase to a maximum value at α = 0.5 and then decrease

Answer : A dc chopper is fed from a constant voltage mains the duty ratio of chopper is progressively increased while the chopper feeds an RL load. The per unit current ripple would increase to a maximum value at α = 0.5 and then decrease

Description : A good voltage regulation of a transformer means?

Answer : A good voltage regulation of a transformer means output voltage fluctuation from no load to full load is least.

Description : The voltage transformation ratio of a transformer is equal to the ratio of?

Answer : The voltage transformation ratio of a transformer is equal to the ratio of secondary induced e.m.f. to primary induced e.m.f.

Description : If a transformer is switched on to a voltage more than the rated voltage?

Answer : If a transformer is switched on to a voltage more than the rated voltage its power factor will deteriorate.

Answer : The no load current in a transformer lags behind the applied voltage by an angle of about 75°.

Description : Auto-transformer makes effective saving on copper and copper losses, when its transformation ratio is?

Answer : Auto-transformer makes effective saving on copper and copper losses, when its transformation ratio is approximately equal to 1.

Description : A 40 kVA transformer has a core loss of 400 W and a full load copper loss of 800 W. The proportion of full load at maximum efficiency is

Answer : A 40 kVA transformer has a core loss of 400 W and a full load copper loss of 800 W. The proportion of full load at maximum efficiency is 0.707

Description : A transformer operates 24 hours day at full -load. It's full -load efficiency is :  (A) equal all day efficiency (B) more than all -day efficiency (C) less than all -day efficiency (D) equal to maximum efficiency

Answer : A transformer operates 24 hours day at full -load. It's full -load efficiency is : equal all day efficiency 

Description : A 3-phase voltage source inverter operates in 180° conduction mode with a star connected resistive load. If input dc voltage is 100 V, then the peak to peak output line voltage is :

Answer : A 3-phase voltage source inverter operates in 180° conduction mode with a star connected resistive load. If input dc voltage is 100 V, then the peak to peak output line voltage is : 200 V

Answer : In a level compounded D.C. generator, full load terminal voltage is equal to no-load terminal voltage.

Answer : In over compounded generator, full load terminal voltage is more than no load terminal voltage.

Description : An SSB transmitter produces a peak-to-peak voltage of 200 V across a 100 Ω antenna load. What is the Peak Envelope Power? A) 49.98 W B) 79.98 W C) 99.96 W D) 199.93 W

Answer : An SSB transmitter produces a peak-to-peak voltage of 200 V across a 100 Ω antenna load. What is the Peak Envelope Power? A) 49.98 W B) 79.98 W C) 99.96 W D) 199.93 W

Description : A zener voltage regulator has load requirements of 12 V and 2 A. The zener diode minimum current requirement is 0.2 A. The minimum voltage at input is 24 V. What is the required value of series resistance with source? A) 5.45 Ω B) 6 Ω C) 7.2 Ω D) 6.38 Ω  

Answer : A zener voltage regulator has load requirements of 12 V and 2 A. The zener diode minimum current requirement is 0.2 A. The minimum voltage at input is 24 V. What is the required value of series resistance with source? A) 5.45 Ω B) 6 Ω C) 7.2 Ω D) 6.38 Ω  

Description : For given applied voltage, with the increase in frequency of the applied voltage?

Answer : For given applied voltage, with the increase in frequency of the applied voltage eddy current loss will remain unchanged.

Description : Losses which occur in rotating electric machines and do not occur in transformers are?

Answer : Friction losses windage losses 

Answer : Induction cup relay is operated due to changes in current, voltage, impedance.

Description : Step-down transformer converts high voltage and low current into:  (A) How voltage and high current (B) High voltage and low current (C) Low voltage and high current (D) None of the above

Answer : Step-down transformer converts high voltage and low current into: Low voltage and high current

Description : The kVA rating of Three-phase transformer with Voltage = 200V and Current = 100A will be :  (A) 34.64 kVA (B) 75 kVA (C) 20 kVA (D) None of the above

Answer : The kVA rating of Three-phase transformer with Voltage = 200V and Current = 100A will be : 34.64 kVA

Description : What is a capacitor voltage transformer? A) It is a transformer used in power systems to step up low voltage signals and provide extra high voltage B) It is a transformer used in power systems ... in power systems to step down extra high voltage signals and provide low voltage D) None of these

Answer : What is a capacitor voltage transformer? A) It is a transformer used in power systems to step up low voltage signals and provide extra high voltage B) It is a transformer used in power systems ... power systems to step down extra high voltage signals and provide low voltage D) None of these

Description : What is impulse voltage of transformer?

Answer : yes High Voltage side of Transformer winding have more number of turns. and low voltage side of Transformer winding have less number of turns.

Answer : When a given transformer is run at its rated voltage but reduced frequency, its core flux density is increased.

Description : The time constant of the capacitance circuit is defined as the time during which voltage?

Answer : The time constant of the capacitance circuit is defined as the time during which voltage rises to 63.2% of its final steady value.

Answer : The power transformer is a constant main flux device.

Description : The time constant of a series R-C circuit is given by?

Answer : The time constant of a series R-C circuit is given by RC.

Description : Time constant of a circuit is the time in seconds taken after the application of voltage to each?

Answer : Time constant of a circuit is the time in seconds taken after the application of voltage to each 63% of maximum value.

Description : State and justify which of the following two transformers is better:  Transformer A = 4% voltage regulation  Transformer B = 6% voltage regulation

Answer : Transformer A with 4% voltage regulation is better.  Justification: Voltage regulation refers to the percentage change in secondary voltage when load is changed from no-load to full-load with primary voltage ... 4% voltage regulation, which is less as compared to 6% of transformer B, it is better.

Answer : No-load current in a transformer lags behind the voltage by about 75°.

Description : Even at no-load, a transformer draws current from the mains. Why?

Answer : No-load current of a transformer has small magnitude and low power factor.

Answer : The full-load copper loss of a trans¬former is 1600 W. At half-load, the copper loss will be 400 W.

Description : A no-load test is performed on a transformer to determine?

Answer : A no-load test is performed on a transformer to determine magnetizing current and loss.

Description : A transformer at 25 Hz develops 20 W hysteresis loss and 50 W eddy current loss. If the applied voltage and frequency are doubled, the new core losses are (A) 140 W (B) 180 W (C) 240 W (D) 480 W

Answer : A transformer at 25 Hz develops 20 W hysteresis loss and 50 W eddy current loss. If the applied voltage and frequency are doubled, the new core losses are 240 W

Description : The friction losses in Real Transformers are :  (A) 0% (B) 5% (C) 25% (D) 50%

Answer : A

Description : In DC motor iron losses are occurred in?

Answer : In DC motor iron losses are occurred in the armature.

Answer : Iron losses in a D.C. machine are independent of variations in load.

← Prev Question Next Question →
editChoose topic
...