An open-circuit test on a transformer is conducted primarily to measure?

2 Answers

An open-circuit test on a transformer is conducted primarily to measure core loss.

thumb_up_alt 0 like thumb_down_alt 0 dislike
The open-circuit test in a transformer is used to measure
thumb_up_alt 0 like thumb_down_alt 0 dislike

Related questions

Description : Sumpner's test is conducted on transformer to determine?

Answer : Sumpner's test is conducted on transformer to determine temprature.

Answer : Short circuit test on transformers is conducted to determine copper losses.

Answer : Hopkinson's test on D.C. machines is conducted at full-load.

Description : During open circuit test of a transformer?

Answer : During open circuit test of a transformer primary is supplied rated voltage.

Description : A no-load test is performed on a transformer to determine?

Answer : A no-load test is performed on a transformer to determine magnetizing current and loss.

Description : Explain the open delta (delta-delta) test on transformer.

Description : Explain the procedure to perform Short Circuit test on single phase transformer with circuit diagram.

Answer : In short circuit test of transformer the low voltage side is short circuited . On high voltage side the voltmeter is connected in parallel and ammeter in series and also a wattmeter is ... circuit test is done for determining impedance and losses. In this test iron losses is neglected.

Description : Polarity Test of Transformer

Answer : .embed-container { position: relative; padding-bottom: 56.25%; height: 0; overflow: hidden; max-width: 100%; } .embed-container iframe, .embed-container object, .embed-container embed { position: absolute; top: 0; left: 0; width: 100%; height: 100%; }

Description : If a 5-bus test system contains 6 transmission lines and one transformer, how many non-zero elements are there in the system Y-bus ? (A) 25 (B) 12 (C) 11 (D) 19

Answer : If a 5-bus test system contains 6 transmission lines and one transformer, 19 non-zero elements are there in the system Y-bus.

Description : Why phasing out and polarity test is carried out on three phase transformer?

Answer : The phasing out test is carried out to identify the windings (primary and secondary) of corresponding phase of the three phase transformer. The polarity test is carried out to identify the ... identical polarity of the primary and secondary windings of each phase of the three phase transformer.

Answer : It is required to measure the true open circuit e.m.f. of a battery. The best device is D.C. potentiometer.

Description : An unshielded moving iron voltmeter is used to measure the voltage in an AC circuit. The stray DC magnetic field having a component along the axis will be  (1) unaffected (2) decreased (3) increased (4) either decreased or increased depending on the direction of the DC field

Answer : An unshielded moving iron voltmeter is used to measure the voltage in an AC circuit. The stray DC magnetic field having a component along the axis will be either decreased or increased depending on the direction of the DC field

Description : With the help of neat diagram, describe the procedure to carry out phasing out test on a 3 phase transformer. Also state the purpose of conducting this test on 3 phase transformer.

Answer : i) This test is carried out on 3-ph transformer to identify primary & secondary winding belonging to the same phase. ii) As shown in fig above all primary & secondary phases ... of this test is to check the respective phases of primary & secondary windings in 3-ph transformer

Answer : The duration of sudden short-circuit test on a synchronous motor is usually about one second.

Description : When secondary of a current transformer is open-circuited its iron core will be?

Answer : When secondary of a current transformer is open-circuited its iron core will be hot because of heavy iron losses taking place in it due to high flux density.

Description : A single-phase transformer has no-load loss of 64 W, as obtained from an open circuit test. When a short-circuit test is performed on it with 90% of the rated currents flowing in its both LV and HV windings, ... .0% of the rated current (C) 80.0% of the rated current (D) 88.8% of the rated current

Answer : A single-phase transformer has no-load loss of 64 W, as obtained from an open circuit test. When a short-circuit test is performed on it with 90% of the rated currents flowing in its both ... measured loss is 81 W. The transformer has maximum efficiency when operated at 80.0% of the rated current

Answer : Noise level test in a transformer is a type test.

Description : During short circuit test iron losses are negligible because?

Answer : During short circuit test iron losses are negligible because the voltage applied on primary side is low.

Description : A Pyrheliometer is an instrument to measure :  (A) temperature of solar photovoltaic cell  (B) intensity of direct solar radiation at normal incidence  (C) intensity of indirect solar radiation  (D) efficiency of a solar photovoltaic cell

Answer : A Pyrheliometer is an instrument to measure : intensity of direct solar radiation at normal incidence 

Description : List any four measure knobs on front panel on CRO.

Answer : Knobs on front panel of CRO: 1. Power ON- OFF 2. Intensity control 3. Focus control 4. Astigmatism control 5. Volt/Div control 6. Vertical position control 7. Invert 8. Horizontal position control 9. Synchronization. 10. Channel selection.

Description : Equivalent circuit of transformer

Answer : Equivalent Circuit Diagram of Transformer Referred to Primary: V1 -Primary Input voltage I1 - Input Current I0- Exciting current/ No load current Im- Magnetizing component ... equivalent of secondary terminal voltage ZL- Load impedance ZL ′- Primary equivalent of load impedance

Description : What does an electric meter measure?

Description : Explain the need and steps to conduct the reduced voltage running up test on the three phase induction motor.

Description : Slip test is performed to determine :  (A) Slip in an induction motor  (B) Xd and Xq in a salient pole alternator  (C) Synchronous impedance in an alternator  (D) Positive and negative sequence impedances of an alternator

Answer : Slip test is performed to determine :  Xd and Xq in a salient pole alternator 

Description : If a transformer is switched on to a voltage more than the rated voltage?

Answer : If a transformer is switched on to a voltage more than the rated voltage its power factor will deteriorate.

Answer : The purpose of providing an iron core in a transformer is to decrease the reluctance of the magnetic path.

Answer : In an actual transformer the iron loss remains practically constant from no load to full load because core flux remains practically constant.

Description : Brake test on DC series motor

Answer : .embed-container { position: relative; padding-bottom: 56.25%; height: 0; overflow: hidden; max-width: 100%; } .embed-container iframe, .embed-container object, .embed-container embed { position: absolute; top: 0; left: 0; width: 100%; height: 100%; }

Description : How do you test an SCR?

Description : What is an insulation resistance test?

Description : Explain the effect of Harmonics on the Transformer.

Answer : Effect of Harmonics on the Transformer:  1. Core loss: Harmonic voltage increases the hysteresis and eddy current losses in the lamination. The amount of the core loss depends on ... small core vibrations.  5. Saturation problem: Sometimes additional harmonic voltage causes core saturation.

Description : Write about transformer on DC.

Answer : Transformer on DC : Transformer cannot work on DC. Transformer works on electromagnetic induction principle. Electromagnetic induction principle means when flux linking with coil changes and EMF induced in it ... winding insulation will burn. https://youtu.be/TVp_0fIfxqY

Answer : In a transformer, the tappings are generally provided on low voltage side.

Description : The size of a transformer core will depend on?

Answer : The size of a transformer core will depend on frequency and area of the core.

Description : Draw venture meter and write steps to measure flow rate.

Answer : Venturi meter consists of three sections that is converging section, throat section and diverging section. The flow is introduced to the meter through the inlet with diameter D' . The inclined angle ... to 15o . Flow rate is proportional to the square root of the differential pressure.

Description : Explain the term reactive power. Why it is sometimes essential to measure reactive power?

Answer : Reactive power: The reactive power (Q) is defined as the product of voltage(V), current (I) and sine of angle between voltage(V) and current( I) Therefore Reactive power Q = V I ... power so that corrective measures can be taken accordingly to maintain systems power factor near to the unity.

Description : ‘PMMC instrument is not suitable to measure AC quantity’. State the reason.

Answer : The direction of force exerted on moving coil depends on the direction of current flowing through moving coil. If the direction of magnetic field is kept constant, it produces unidirectional torque if the current is ... on the coil in one cycle to zero. Hence the meter cannot read A.C. quantities.

Description : Name the method used to measure following resistances:- (i) Low resistance (ii) Medium resistance (iii) Insulation resistance (iv) Earth resistance.

Answer : Following are the methods used to measure resistances:-  (i) Low resistance: 1.Voltmeter-Ammeter Method 2. Kelvin's Double bridge Method  (ii) Medium resistance: 1.Voltmeter-Ammeter Method 2. ... of Charge Method  (iv) Earth resistance : 1. Fall of Potential Method 2. Earth tester

Description : A _________ is used to measure the stator % winding temperature of the generator.  (A) Thermocouple (B) Pyrometer (C) Resistance thermometer (D) Thermometer

Answer : A Resistance thermometer is used to measure the stator % winding temperature of the generator. 

Description : Piezoelectric Transducer is used to measure  (1) displacement (2) resistance (3) current (4) temperature

Answer : Piezoelectric Transducer is used to measure displacement 

Description : Which of the following can be used to measure the capacitance of a capacitor? A) Rheostat B) Schering bridge C) Wheatstone bridge D) None of these

Answer : Which of the following can be used to measure the capacitance of a capacitor? A) Rheostat B) Schering bridge C) Wheatstone bridge D) None of these

Answer : To measure a resistance with the help of a potentiometer it is not necessary to standardise the potentiometer.

Description : What type of meter is used to measure current?

Answer : Ammeter

Description : What equipment is used to measure voltage?

Answer : Voltmeter is used to measure voltage.

Description : State why a transformer always have an efficiency of more than 90%.

Answer : As transformer is static device with no moving parts, the losses due to friction & windage are completely absent. Hence transformer has efficiency of more than 90%.