A no-load test is performed on a transformer to determine?

1 Answer

A no-load test is performed on a transformer to determine magnetizing current and loss.
thumb_up_alt 0 like thumb_down_alt 0 dislike

Related questions

Description : Slip test is performed to determine :  (A) Slip in an induction motor  (B) Xd and Xq in a salient pole alternator  (C) Synchronous impedance in an alternator  (D) Positive and negative sequence impedances of an alternator

Answer : Slip test is performed to determine :  Xd and Xq in a salient pole alternator 

Answer : Short circuit test on transformers is conducted to determine copper losses.

Description : Sumpner's test is conducted on transformer to determine?

Answer : Sumpner's test is conducted on transformer to determine temprature.

Description : Even at no-load, a transformer draws current from the mains. Why?

Description : An open-circuit test on a transformer is conducted primarily to measure?

Answer : The open-circuit test in a transformer is used to measure

Description : During open circuit test of a transformer?

Answer : During open circuit test of a transformer primary is supplied rated voltage.

Description : Explain the procedure to perform Short Circuit test on single phase transformer with circuit diagram.

Description : Explain the open delta (delta-delta) test on transformer.

Description : Polarity Test of Transformer

Answer : .embed-container { position: relative; padding-bottom: 56.25%; height: 0; overflow: hidden; max-width: 100%; } .embed-container iframe, .embed-container object, .embed-container embed { position: absolute; top: 0; left: 0; width: 100%; height: 100%; }

Description : If a 5-bus test system contains 6 transmission lines and one transformer, how many non-zero elements are there in the system Y-bus ? (A) 25 (B) 12 (C) 11 (D) 19

Answer : If a 5-bus test system contains 6 transmission lines and one transformer, 19 non-zero elements are there in the system Y-bus.

Answer : In short circuit test of transformer the low voltage side is short circuited . On high voltage side the voltmeter is connected in parallel and ammeter in series and also a wattmeter is ... circuit test is done for determining impedance and losses. In this test iron losses is neglected.

Description : Why phasing out and polarity test is carried out on three phase transformer?

Answer : The phasing out test is carried out to identify the windings (primary and secondary) of corresponding phase of the three phase transformer. The polarity test is carried out to identify the ... identical polarity of the primary and secondary windings of each phase of the three phase transformer.

Answer : Series motor should not be started on no-load.

Answer : In an actual transformer the iron loss remains practically constant from no load to full load because core flux remains practically constant.

Description : In a battery, the difference between the no-load voltage and the measured voltage output is called ________ A) Internal voltage B) Internal resistance C) External resistance D) All the above

Answer : In a battery, the difference between the no-load voltage and the measured voltage output is called Internal resistance

Description : The no-load speed of a single-phase SCR bridge converter fed separately excited dc motor operating at a firing delay angle, α and flux, Φ (A) directly proportional to α and Φ (B) ... proportional to α and inversely proportional to Φ (D) directly proportional to Φ and inversely proportional to α

Answer : The no-load speed of a single-phase SCR bridge converter fed separately excited dc motor operating at a firing delay angle, α and flux, Φ directly proportional to α and inversely proportional to Φ

Answer : No-load current in a transformer lags behind the voltage by about 75°.

Answer : The no load current in a transformer lags behind the applied voltage by an angle of about 75°.

Answer : No-load current of a transformer has small magnitude and low power factor.

Description : With the help of neat diagram, describe the procedure to carry out phasing out test on a 3 phase transformer. Also state the purpose of conducting this test on 3 phase transformer.

Answer : i) This test is carried out on 3-ph transformer to identify primary & secondary winding belonging to the same phase. ii) As shown in fig above all primary & secondary phases ... of this test is to check the respective phases of primary & secondary windings in 3-ph transformer

Description : A parallel RLC circuit has the node equation Determine v(t) using the phasor method.

Answer : A parallel RLC circuit has the node equation Determine v(t) using the phasor method.

Description : Using phasors, determine in the following equations

Answer : Using phasors, determine in the following equations

Answer : Noise level test in a transformer is a type test.

Description : The inrush current of a transformer at no load is maximum if the supply voltage is switched on  (1) at peak voltage value (2) at zero voltage value (3) at half voltage value (4) at 0.866 time voltage value

Answer : At 0.866 time voltage value

Answer : The full-load copper loss of a trans¬former is 1600 W. At half-load, the copper loss will be 400 W.

Answer : An ideal transformer will have maximum efficiency at a load such that copper loss equal to iron loss.

Description : In a given transformer for a given applied voltage, losses which remain constant irrespective of load changes are?

Answer : In a given transformer for a given applied voltage, losses which remain constant irrespective of load changes are hysteresis and eddy current losses.

Description : For a transformer, operating at constant load current, maximum efficiency will occur at?

Answer : For a transformer, operating at constant load current, maximum efficiency will occur at unity power factor.

Description : The maximum load that a power transformer can carry is limited by its?

Answer : The maximum load that a power transformer can carry is limited by its voltage ratio.

Description : In a step-down transformer, there is a change of 15 A in the load current. This results in change of supply current of?

Answer : In a step-down transformer, there is a change of 15 A in the load current. This results in change of supply current of less than 15A.

Description : A single-phase transformer has no-load loss of 64 W, as obtained from an open circuit test. When a short-circuit test is performed on it with 90% of the rated currents flowing in its both LV and HV windings, ... .0% of the rated current (C) 80.0% of the rated current (D) 88.8% of the rated current

Answer : A single-phase transformer has no-load loss of 64 W, as obtained from an open circuit test. When a short-circuit test is performed on it with 90% of the rated currents flowing in its both ... measured loss is 81 W. The transformer has maximum efficiency when operated at 80.0% of the rated current

Description : Explain the need and steps to conduct the reduced voltage running up test on the three phase induction motor.

Description : If a transformer is switched on to a voltage more than the rated voltage?

Answer : If a transformer is switched on to a voltage more than the rated voltage its power factor will deteriorate.

Description : Brake test on DC series motor

Answer : .embed-container { position: relative; padding-bottom: 56.25%; height: 0; overflow: hidden; max-width: 100%; } .embed-container iframe, .embed-container object, .embed-container embed { position: absolute; top: 0; left: 0; width: 100%; height: 100%; }

Answer : Hopkinson's test on D.C. machines is conducted at full-load.

Answer : The duration of sudden short-circuit test on a synchronous motor is usually about one second.

Description : Explain the effect of Harmonics on the Transformer.

Answer : Effect of Harmonics on the Transformer:  1. Core loss: Harmonic voltage increases the hysteresis and eddy current losses in the lamination. The amount of the core loss depends on ... small core vibrations.  5. Saturation problem: Sometimes additional harmonic voltage causes core saturation.

Description : Write about transformer on DC.

Answer : Transformer on DC : Transformer cannot work on DC. Transformer works on electromagnetic induction principle. Electromagnetic induction principle means when flux linking with coil changes and EMF induced in it ... winding insulation will burn. https://youtu.be/TVp_0fIfxqY

Answer : In a transformer, the tappings are generally provided on low voltage side.

Description : The size of a transformer core will depend on?

Answer : The size of a transformer core will depend on frequency and area of the core.

Description : During short circuit test iron losses are negligible because?

Answer : During short circuit test iron losses are negligible because the voltage applied on primary side is low.

Answer : The purpose of providing an iron core in a transformer is to decrease the reluctance of the magnetic path.

Answer : Gas is usually not liberated due to dissociation of transformer oil unless the oil temperature exceeds 150°C.

Answer : If the supply frequency to the transformer is increased, the iron loss will increase.

Answer : A transformer can have regulation closer to zero on leading power factor.

Description : The hum in a transformer is mainly attributed to?

Answer : The hum in a transformer is mainly attributed to magnetostriction.