If a transformer is switched on to a voltage more than the rated voltage?

1 Answer

If a transformer is switched on to a voltage more than the rated voltage its power factor will deteriorate.

thumb_up_alt 0 like thumb_down_alt 0 dislike

Related questions

Description : In a lamp load when more than one lamp are switched on the total resistance of the load?

Answer : In a lamp load when more than one lamp are switched on the total resistance of the load decreases.

Description : The voltage transformation ratio of a transformer is equal to the ratio of?

Answer : The voltage transformation ratio of a transformer is equal to the ratio of secondary induced e.m.f. to primary induced e.m.f.

Description : In a given transformer for a given applied voltage, losses which remain constant irrespective of load changes are?

Answer : In a given transformer for a given applied voltage, losses which remain constant irrespective of load changes are hysteresis and eddy current losses.

Description : A good voltage regulation of a transformer means?

Answer : A good voltage regulation of a transformer means output voltage fluctuation from no load to full load is least.

Answer : Power plant having maximum demand more than the installed rated capacity will have utilisation factor more than unity.

Answer : yes High Voltage side of Transformer winding have more number of turns. and low voltage side of Transformer winding have less number of turns.

Description : The inrush current of a transformer at no load is maximum if the supply voltage is switched on  (1) at peak voltage value (2) at zero voltage value (3) at half voltage value (4) at 0.866 time voltage value

Answer : At 0.866 time voltage value

Description : A capacitor-start single phase induction motor is switched on to supply with its capacitor replaced by an inductor of equivalent reactance value. It will?

Answer : A capacitor-start single phase induction motor is switched on to supply with its capacitor replaced by an inductor of equivalent reactance value. It will not start at all.

Answer : Generating capacity connected to the bus bars and ready to take load when switched on is known as spinning reserve.

Answer : When a given transformer is run at its rated voltage but reduced frequency, its core flux density is increased.

Description : The maximum constant load torque under which a synchronous motor will pull into synchronism at rated rotor supply voltage and frequency is known as?

Answer : The maximum constant load torque under which a synchronous motor will pull into synchronism at rated rotor supply voltage and frequency is known as pull-in torque.

Description : The maximum torque which a synchronous motor will develop at rest for any angular position of the rotor, at rated stator supply voltage and frequency, is known as?

Description : Step-down transformer converts high voltage and low current into:  (A) How voltage and high current (B) High voltage and low current (C) Low voltage and high current (D) None of the above

Answer : Step-down transformer converts high voltage and low current into: Low voltage and high current

Description : The kVA rating of Three-phase transformer with Voltage = 200V and Current = 100A will be :  (A) 34.64 kVA (B) 75 kVA (C) 20 kVA (D) None of the above

Answer : The kVA rating of Three-phase transformer with Voltage = 200V and Current = 100A will be : 34.64 kVA

Description : A transformer has negative voltage regulation when its load power factor is   (1) Zero (2) Unity (3) Leading (4) Lagging

Answer : Leading

Description : What is a capacitor voltage transformer? A) It is a transformer used in power systems to step up low voltage signals and provide extra high voltage B) It is a transformer used in power systems ... in power systems to step down extra high voltage signals and provide low voltage D) None of these

Answer : What is a capacitor voltage transformer? A) It is a transformer used in power systems to step up low voltage signals and provide extra high voltage B) It is a transformer used in power systems ... power systems to step down extra high voltage signals and provide low voltage D) None of these

Description : What is impulse voltage of transformer?

Description : Sparking occurs when a load is switched off because the circuit has high?

Answer : Sparking occurs when a load is switched off because the circuit has high inductance.

Description : Thyristor Switched Capacitor (TSC)

Answer : Thyristor Switched Capacitor (TSC)  TSC is a static compensator. TSC is use for compensating reactive power. Compensation is required for voltage regulation, increasing stability, ... compensating device like TCS phase angle between voltage and current can be maintain.

Description : State why a transformer always have an efficiency of more than 90%.

Answer : As transformer is static device with no moving parts, the losses due to friction & windage are completely absent. Hence transformer has efficiency of more than 90%.

Answer : A heater is rated as 230 V, 10 kW, A.C. The value 230 V refers to r.m.s. voltage.

Description : A 240 V, dc shunt motor draws 15 A while supplying the rated load at a speed of 80 rad/s. The armature resistance is 0.5 W and the field winding resistance is 80 W. The net Voltage across armature resistance at the time of plugging will be

Answer : A 240 V, dc shunt motor draws 15 A while supplying the rated load at a speed of 80 rad/s. The armature resistance is 0.5 W and the field winding resistance is 80 W. The net Voltage across armature resistance at the time of plugging will be 474 V

Description : A 50 Hz, 4 pole turboalternator rated at 20 MVA. 13.2 KV has an inertia constant H = 4 KW sec/KVA. The K.E. stored in the rotor at synchronous speed is

Answer : A 50 Hz, 4 pole turboalternator rated at 20 MVA. 13.2 KV has an inertia constant H = 4 KW sec/KVA. The K.E. stored in the rotor at synchronous speed is 80 MJ

Description : Capacitors for power factor correction are rated in?

Answer : Capacitors for power factor correction are rated in kVAR.

Answer : In the transformer low voltage winding has got more cross-sectional area.

Answer : High voltage winding in a transformer has more number of turns.

Description : State and justify which of the following two transformers is better:  Transformer A = 4% voltage regulation  Transformer B = 6% voltage regulation

Answer : Transformer A with 4% voltage regulation is better.  Justification: Voltage regulation refers to the percentage change in secondary voltage when load is changed from no-load to full-load with primary voltage ... 4% voltage regulation, which is less as compared to 6% of transformer B, it is better.

Answer : A transformer cannot raise or lower the voltage of a D.C. supply because Faraday's laws of electromagnetic induction are not valid since the rate of change of flux is zero.

Answer : The no load current in a transformer lags behind the applied voltage by an angle of about 75°.

Answer : If the supply frequency to the transformer is increased, the iron loss will increase.

Description : If a transformer is continuously operated the maximum temperature rise will occur in?

Answer : If a transformer is continuously operated the maximum temperature rise will occur in windings.

Description : An open-circuit test on a transformer is conducted primarily to measure?

Answer : The open-circuit test in a transformer is used to measure

Description : A no-load test is performed on a transformer to determine?

Answer : A no-load test is performed on a transformer to determine magnetizing current and loss.

Description : Sumpner's test is conducted on transformer to determine?

Answer : Sumpner's test is conducted on transformer to determine temprature.

Description : Explain the effect of Harmonics on the Transformer.

Answer : Effect of Harmonics on the Transformer:  1. Core loss: Harmonic voltage increases the hysteresis and eddy current losses in the lamination. The amount of the core loss depends on ... small core vibrations.  5. Saturation problem: Sometimes additional harmonic voltage causes core saturation.

Description : Write about transformer on DC.

Answer : Transformer on DC : Transformer cannot work on DC. Transformer works on electromagnetic induction principle. Electromagnetic induction principle means when flux linking with coil changes and EMF induced in it ... winding insulation will burn. https://youtu.be/TVp_0fIfxqY

Answer : In a transformer, the tappings are generally provided on low voltage side.

Description : The size of a transformer core will depend on?

Answer : The size of a transformer core will depend on frequency and area of the core.

Description : A transformer at 25 Hz develops 20 W hysteresis loss and 50 W eddy current loss. If the applied voltage and frequency are doubled, the new core losses are (A) 140 W (B) 180 W (C) 240 W (D) 480 W

Answer : A transformer at 25 Hz develops 20 W hysteresis loss and 50 W eddy current loss. If the applied voltage and frequency are doubled, the new core losses are 240 W

Description : The voltage applied to the H.V. side of a transformer during S.C. test is 2% of the rated voltage. The core loss as the fraction of its rated core loss is (a) 4% (b) 0.4% (c) 0.25% (d) 0.04%

Answer : The purpose of providing an iron core in a transformer is to decrease the reluctance of the magnetic path.

Answer : Gas is usually not liberated due to dissociation of transformer oil unless the oil temperature exceeds 150°C.

Answer : In an actual transformer the iron loss remains practically constant from no load to full load because core flux remains practically constant.

Answer : A transformer can have regulation closer to zero on leading power factor.

Description : The hum in a transformer is mainly attributed to?

Answer : The hum in a transformer is mainly attributed to magnetostriction.

Description : Part of the transformer which is most subject to damage from overheating is?

Answer : Part of the transformer which is most subject to damage from overheating is winding insulation.

Description : The dielectric strength of transformer oil is expected to be?

Answer : The dielectric strength of transformer oil is expected to be 33 kV.

Description : List two special feature of welding transformer.

Answer : Special features of welding transformer: i) It is a step down transformer that reduces the source voltage to a voltage desired according to the demands of the welding process. ii) Having large primary turns and less ... V ii) Secondary voltage - 40 to 60 V iii) Secondary current - 200 to 600 A

Description : State two applications of isolation transformer

Answer : Applications of isolation transformer: i) Isolates the load equipment from supply ground: ii) Reduction of voltage spikes iii) It acts as a decoupling device. iv) Protects loads from harmonic distortion.

Description : Equivalent circuit of transformer

Answer : Equivalent Circuit Diagram of Transformer Referred to Primary: V1 -Primary Input voltage I1 - Input Current I0- Exciting current/ No load current Im- Magnetizing component ... equivalent of secondary terminal voltage ZL- Load impedance ZL ′- Primary equivalent of load impedance

← Prev Question Next Question →
editChoose topic
...