In which fault the maximum short circuit current occurs?

1 Answer

In three phase bolted fault the maximum short circuit occurs.

thumb_up_alt 0 like thumb_down_alt 0 dislike

Related questions

Description : If the % reactance upto the fault point is 20%, then the short circuit current will be

Answer : If the % reactance upto the fault point is 20%, then the short circuit current will be 5 times the full load current

Answer : Reactance relay is preferred for phase fault on short transmission line.

Description : The armature current on symmetrical 3 phase short circuit of a synchronous machine (salient pole)  (A) has q -axis current only (B) has d -axis current only (C) has both d and q axis currents (D) cannot be divided between q and d axis currents

Answer : The armature current on symmetrical 3 phase short circuit of a synchronous machine (salient pole) has d -axis current only

Description : If the fault current is 6000 A, the relay plug setting is 150% and the CT ratio is 400/5, the plug setting multiplier will be

Answer : If the fault current is 6000 A, the relay plug setting is 150% and the CT ratio is 400/5, the plug setting multiplier will be 10

Answer : The inverse definite mean time relays are used for over current and earth fault protection of transformer against internal short-circuits.

Answer : The short circuit in any winding of the transformer is the result of impulse voltage.

Description : If the fault current is 2000 A, the relay setting is 50% and CT ratio is 400:5, the plug setting multiplier will be

Answer : If the fault current is 2000 A, the relay setting is 50% and CT ratio is 400:5, the plug setting multiplier will be 10 A

Description : Which of the following are known as the short circuit parameters of a 2- port network? (A) Z- parameters. (B) H- parameters. (C) Y- parameters. (D) A,B,C,D, parameters.

Answer : Which of the following are known as the short circuit parameters of a 2- port network? (A) Z- parameters. (B) H- parameters. (C) Y- parameters. (D) A,B,C,D, parameters.

Answer : In short circuit test of transformer the low voltage side is short circuited . On high voltage side the voltmeter is connected in parallel and ammeter in series and also a wattmeter is ... circuit test is done for determining impedance and losses. In this test iron losses is neglected.

Description : Explain the procedure to perform Short Circuit test on single phase transformer with circuit diagram.

Description : Describe the difference between an open circuit and a short circuit.

Answer : Open circuit means the wire is cut meaning power will not flow and close circuit means wire is not cut and hence power will flow.Short circuit is the same as close circuit

Answer : Short circuit test on transformers is conducted to determine copper losses.

Description : What can cause a short circuit?

Answer : In a D.C. shunt motor, under the conditions of maximum power, the current in the armature will be more than full-load current.

Description : In the induction type directional over current relay, when a short-circuit occurs in the circuit (A) power flows in reverse direction (B) power flows in normal direction (C) directional power element does not operate (D) over current element is not energized

Answer : In the induction type directional over current relay, when a short-circuit occurs in the circuit power flows in reverse direction

Description : For a transformer, operating at constant load current, maximum efficiency will occur at?

Answer : For a transformer, operating at constant load current, maximum efficiency will occur at unity power factor.

Description : What is the maximum number of circuit breakers in a panel?

Answer : It depends on that which type of panel is this.

Description : State maximum power transfer theorem for DC circuit.

Answer : Maximum power transfer theorem for DC circuit: The maximum power transfer theorem states that the source or a network transfers maximum power to load only when the load resistance is equal ... removed (disconnected) ii) All internal independent sources are replaced by their internal resistances.

Description : Which is the most common type of fault?

Answer : Single phase to ground fault is the most common type of fault.

Description : If an unsymmetrical line to ground fault occurs at the secondary terminals of a delta/star, ungrounded transformer, then  (A) zero sequence currents are present on both sides of the transformer  (B) ... side  (D) zero sequence currents are present on the primary side but not on the secondary side

Answer : If an unsymmetrical line to ground fault occurs at the secondary terminals of a delta/star, ungrounded transformer, then zero sequence currents are absent on both sides of the transformer 

Description : With fault clearing time, the transient stability of a power system

Answer : With fault clearing time, the transient stability of a power system decreases

Description : To protect the power transformer (Y-Y with neutral grounded) against fault, what type of connection do the CTs have ?

Answer : To protect the power transformer (Y-Y with neutral grounded) against fault, what type of connection do the CTs have ? Δ-Δ connection

Answer : Fault diverters are basically fast switches.

Description : Explain why potential difference is necessary to produce current in a circuit.

Description : In a series R-C circuit, with the increase in frequency, current (A) Reduces (B) Increases (C) Does not change (D) Becomes zero

Answer : In a series R-C circuit, with the increase in frequency, current Increases

Description : In parallel RLC resonance circuit at resonance the current will be  (1) Minimum (2) Maximum (3) Zero (4) Infinite

Answer : In parallel RLC resonance circuit at resonance the current will be Minimum 

Description : In a series RLC high Q circuit, the current peaks at a frequency  (1) equal to the resonant frequency (2) greater than the resonant frequency (3) less than the resonant frequency (4) equal to half the resonant frequency

Answer : In a series RLC high Q circuit, the current peaks at a frequency equal to the resonant frequency

Description : Magnitude of current at resonance in R-L-C circuit?

Answer : The current will be maximum if it is a series rlc circuit.

Description : In a loss-free R-L-C circuit the transient current is?

Answer : In a loss-free R-L-C circuit the transient current is sinusoidal.

Description : What is the direction of flow of electric current in an electric circuit?

Answer : It  flows  from  anode  to  cathode  (direction  of   holes  flow)

Description : When one leg of parallel circuit is opened out the total current will?

Answer : When one leg of parallel circuit is opened out the total current will decrease.

Description : Electric current passing through the circuit produces?

Answer : Electric current passing through the circuit produces thermal effect.

Description : Refer to the circuit below. The total absorbed (consumed) power is:

Description : Give the causes and impact and reasons of grid system fault. 

Answer : Following are the causes/reasons grid system fault: 1. Major imbalance between generation and consumption i.e. demand is more than generation. 2. Low frequency, due to some faults the frequency ... of supply and causes inconvenience to people. 6. Disturb the routine work of common all people.

Description : A shunt fault is characterized by (A) Increase in current, frequency and pf (B) Increase in current, reduction in frequency and pf (C) Increase in current and frequency, reduction in pf (D) Decrease in current and frequency

Answer : B

Description : The inrush current of a transformer at no load is maximum if the supply voltage is switched on  (1) at peak voltage value (2) at zero voltage value (3) at half voltage value (4) at 0.866 time voltage value

Answer : At 0.866 time voltage value

Description : The current zero interruption, in oil and air blast circuit breakers, is achieved by?

Answer : The current zero interruption, in oil and air blast circuit breakers, is achieved by lengthening of the gap, cooling and blast effect.

Description : State advantages of short pitch winding over full pitch winding in alternators. 

Answer : Advantages of Short Pitch Winding over Full Pitch Winding in Alternators: 1) Short pitching reduces the amount of copper needed for end connection when compared with full pitched coil. 2) They ... reduced, thereby increasing the efficiency. 4) The power quality of generated emf is improved. 

Description : State the effects of low power factor on efficiency and voltage regulation of short transmission lines. 

Answer : i) Effect of Low power factor on efficiency:- When power factor of load reduces current drawn by transmission line increases so copper losses in transmission line increases, hence transmission ... increases, so voltage drop in transmission line increases so regulation increases. (Become Poor) 

Description : 3X3 inverse of matrix short trick

Answer : 3X3 inverse of matrix short trick

Description : For a short transmission line with r/x ratio of is 1.0, the regulation will be zero when the load power factor is

Answer : For a short transmission line with r/x ratio of is 1.0, the regulation will be zero when the load power factor is 0.707 lead

Answer : Armature coil is short circuited by brushes when it lies along neutral axis.

Description : what is mean by short transmission line ?

Answer : The transmission lines which have length less than 80 km is known as short transmission lines.

Answer : Series motor has got maximum self relieving property.

Description : The maximum constant load torque under which a synchronous motor will pull into synchronism at rated rotor supply voltage and frequency is known as?

Answer : The maximum constant load torque under which a synchronous motor will pull into synchronism at rated rotor supply voltage and frequency is known as pull-in torque.

Description : The maximum torque which a synchronous motor will develop at rest for any angular position of the rotor, at rated stator supply voltage and frequency, is known as?

Description :  An independent voltage source in series with an impedance ZS=R+jXS delivers a maximum average power to a load impedance ZL when A) ZL = R B) ZL = jXS C) ZL = R-jXS D) ZL = R+jXS 

Answer :  An independent voltage source in series with an impedance ZS=R+jXS delivers a maximum average power to a load impedance ZL when ZL = R-jXS

← Prev Question Next Question →
editChoose topic
...