If we change the excitation of synchronous machine will it affect on power factor?

1 Answer

Yes, If we change the excitation of synchronous machine it will affect on power factor. If the synchronous motor is overexcited then it will have leading power factor and if the motor is underexcited then it will have lagging power factor.

thumb_up_alt 0 like thumb_down_alt 0 dislike

Related questions

Description : If we change the excitation of synchronous machine will it affect on motor speed?

Answer : No, If we change the excitation of synchronous machine it will not affect on motor speed.

Answer : Yes, we can make the power factor of synchronous motor leading by adjusting its excitation.

Description : If the load of the normally excited synchronous motor is increased the power factor will?

Answer : If the load of the normally excited synchronous motor is increased the power factor will become lagging.

Description : If the field of synchronous motor is under excited, power factor will be?

Answer : If the field of synchronous motor is under excited, power factor will be lagging.

Answer : Synchronsizing power of a synchronous machine is inversely proportional to the synchronous reactance.

Description : The synchronous motor which works on leading power factor and does not drive any mechanical load is called?

Answer : The synchronous motor which works on leading power factor and does not drive any mechanical load is called synchronous condenser.

Description : what will happen when excitation of an unloaded salient pole synchronous motor suddenly gets disconnected?

Answer : When excitation of an unloaded salient pole synchronous motor suddenly gets disconnected the motor will stop.

Description : A synchronous motor has better power factor as compared to that of an equivalent induction motor. This is mainly because?

Answer : A synchronous motor has better power factor as compared to that of an equivalent induction motor. This is mainly because stator supply is not required to produce magnetic field.

Answer : The standard full-load power factor ratings for synchronous motors are unity or 0.8 leading.

Answer : For power factor correction, synchronous motors operate at no-load and greatly over-excited fields.

Description : How can we improve power factor using synchronous motor?

Answer : A synchronous motor running with normal excitation adjusts to load increases essentially by increase in armature current.

Answer : In two part tariff, variation in load factor will affect operating or running charges.

Description : In a synchronous generator if the excitation increased from a low value to normal value, with a fixed load  (A) The armature current increases and the power factor decreases  (B) The armature ... but is lagging  (D) The armature current decreases and the power factor increases and is leading

Answer : In a synchronous generator if the excitation increased from a low value to normal value, with a fixed load The armature current decreases and the power factor increases and is leading

Description : In a synchronous generator delivering lagging power factor load  (1) the excitation emf leads terminal voltage by the power angle (2) the excitation emf lags terminal voltage by the power angle (3) ... by the power factor angle (4) excitation emf lags the terminal voltage by the power factor angle

Answer : In a synchronous generator delivering lagging power factor load the excitation emf leads terminal voltage by the power angle

Description : The power factor angle and torque angle of a salient pole synchronous generator drawing a current of 1.0 pu from a lagging load are 45o and 15o, respectively. The direct axis and quadrature axis currents, respectively, are (A) 0.5 pu ... pu, 0.5 pu (C) 0.707 pu, 0.707 pu (D) 0.5 pu, 0.5 pu

Answer : The power factor angle and torque angle of a salient pole synchronous generator drawing a current of 1.0 pu from a lagging load are 45o and 15o, respectively. The direct axis and quadrature axis currents, respectively, are 0.866 pu, 0.5 pu

Answer : In a distribution system, in order to improve power factor, the synchronous capacitors are installed at the receiving end.

Description : Can a synchronous condenser improve power factor?

Answer : Yes, synchronous condenser can improve power factor.

Description : The effect of increasing load on a synchronous motor running with normal excitation is (A) Increase both its Ia and power factor. (B) Decrease Ia, but increase power factor. (C) Increase Ia, but decrease power factor (D) Decrease both Ia and power factor.

Answer : The effect of increasing load on a synchronous motor running with normal excitation is Increase Ia, but decrease power factor

Answer : A synchronous machine with low value of short-circuit ratio has lower stability limit.

Description : V - curve of synchronous machine shows the relation between?

Answer : V - curve of synchronous machine shows the relation between AC armature current and DC field current.

Description : Why synchronous machine is called doubly excited machine?

Answer : Armature windings of synchronous machines either deliver 3 phase AC or absorb 3 phase AC source,  whereas field windings are energized from DC source. Thus due to presence of AC on armature and DC on field windings, synchronous machines are often referred as doubly excited machines.

Description : Which machine is the exciter of synchronous machine?

Answer : DC shunt machine is the exciter of synchronous machine.

Description : For a 500 Hz frequency excitation, a 50 km long power line will be modeled as

Answer : For a 500 Hz frequency excitation, a 50 km long power line will be modeled as long line

Description : In a synchronous machine, if the field flux axis ahead of the armature field axis in the direction of rotation, the machine is operating as  (1) synchronous motor (2) synchronous generator (3) asynchronous motor (4) asynchronous generator

Answer : In a synchronous machine, if the field flux axis ahead of the armature field axis in the direction of rotation, the machine is operating as synchronous generator 

Description : The synchronous motor will develop maximum power when the load angle is?

Answer : The synchronous motor will develop maximum power when the load angle is 900.

Description : The armature current on symmetrical 3 phase short circuit of a synchronous machine (salient pole)  (A) has q -axis current only (B) has d -axis current only (C) has both d and q axis currents (D) cannot be divided between q and d axis currents

Answer : The armature current on symmetrical 3 phase short circuit of a synchronous machine (salient pole) has d -axis current only

Description : During a disturbance on a synchronous machine, the rotor swings form A to B before finally setting down to steady state at point C on the power angle curve. The speed of the machine during oscillation is synchronous at point(s)

Answer : During a disturbance on a synchronous machine, the rotor swings form A to B before finally setting down to steady state at point C on the power angle curve. The speed of the machine during oscillation is synchronous at point(s) only at C

Description : The 'Equal area criterion' for the determination of transient stability of a synchronous machine connected to an infinite bus  (1) ignores line as well as synchronous machine resistance ... consideration the possibility of machine losing synchronism after it has survived during the first swing.

Answer : 1

Description : Torque angle for the synchronous machine is the angle between (A) stator magnetic field and rotor magnetic field (B) stator magnetic field and net magnetic field in the air gap (C) rotor magnetic field and net magnetic field in the air gap (D) excitation voltage and impedance voltage drop

Answer : Torque angle for the synchronous machine is the angle between rotor magnetic field and net magnetic field in the air gap

Description : Why do we need to correct power factor?

Answer : When a D.C. series motor is connected to A.C. supply, the power factor will be low because of high inductance of field and armature circuits.

Answer : For high value of diversity factor, a power station of given installed capacity will be in a position to supply more number of consumers.

Answer : Power plant having maximum demand more than the installed rated capacity will have utilisation factor more than unity.

Answer : The power factor of a single phase load can be calculated if the instruments available are three ammeters or three voltmeters.

Description : Power factor of an inductive circuit is usually improved by connecting capacitor to it in?

Answer : Power factor of an inductive circuit is usually improved by connecting capacitor to it in parallel.

Description : State the effects of low power factor on efficiency and voltage regulation of short transmission lines. 

Answer : i) Effect of Low power factor on efficiency:- When power factor of load reduces current drawn by transmission line increases so copper losses in transmission line increases, hence transmission ... increases, so voltage drop in transmission line increases so regulation increases. (Become Poor) 

Description : What is the power factor when a single phase watt meter operating on 200 V and 5 A for 5 hours makes 2016 revolutions and the meter constant in revolution is 420? A) 0.04 B) 1.04 C) 0.96 D) None of these

Answer : What is the power factor when a single phase watt meter operating on 200 V and 5 A for 5 hours makes 2016 revolutions and the meter constant in revolution is 420? A) 0.04 B) 1.04 C) 0.96 D) None of these

Description : The power factor of an alternator depends on?

Answer : The power factor of an alternator depends on load.

Answer : If the field winding of an unloaded salient pole synchronous motor is open circuited, the motor will stop.

Description : The maximum reluctance power of a salient-pole synchronous motor having direct-axis reactance, 1.0 pu and quadrature-axis reactance, 0.5 pu, and input voltage, 1.0 pu is (A) 0.25 pu (B) 0.5 pu (C) 1.0 pu (D) 1.5 pu

Answer : The maximum reluctance power of a salient-pole synchronous motor having direct-axis reactance, 1.0 pu and quadrature-axis reactance, 0.5 pu, and input voltage, 1.0 pu is 0.5 pu

Description : How can we reverse the direction of rotation of synchronous motor?

Answer : By reversing supply phase sequence we can reverse the direction of rotation of synchronous motor.

Description : Can we use the synchronous motor as the synchronous capacitor?

Answer : Yes, we can use the synchronous motor as the synchronous capacitor when the synchrnous motor is overexcited.

Answer : If the synchronous motor, properly synchronised to the supply is running on no load and is having negligible loss then the stator current will be zero.

Answer : Capacitor use in fan is made up of dielectic material which is in semi solid material having high capacity.but generation of heat in capacitor the semi solid material converted into dry solid because of ... capacity becomes lower and lower so for good result of our fan we have to change it.

Description : While keeping the excitation constant, if the steam supply of an alternator running in parallel with another identical alternator is increased, then (A) It would over-run the other alternator (B) Its rotor ... (C) Its portion of share in load will increase (D) Its power factor would be decreased.

Answer : While keeping the excitation constant, if the steam supply of an alternator running in parallel with another identical alternator is increased, then Its portion of share in load will increase

Answer : For a D.C. shunt motor if the excitation is changed torque will change but power will remain constant.

Description : Briefly explain how the power factor of an inductive circuit can be improved.

Answer : As we know that power factor should be corrected to ensure that the current supplied is cost friendly. Meaning the power factor should be around one but not greater than one(0.8-0.9) in a ... an inductive circuit due to the inductive reactance which oppose the change of current in the ac circuit. 

Description : What is the value of capacitance required to improve power factor from 0.7 to 0.9. Given that: Real power = 50 W Vrms of the source = 120 Frequency = 50 Hz   #powerfactor

Description : Why capacitors are used to improve power factor?

Answer :  Capacitors generate reactive power instead of that drawn from source which is required by inductive loads.so it reduce the reactive current which is drawn from source to be drawn from capacitor.This control in Electric bills cost.