If the load of the normally excited synchronous motor is increased the power factor will?
thumb_up_alt 0 like thumb_down_alt 0 dislike
116 views

1 Answer

If the load of the normally excited synchronous motor is increased the power factor will become lagging.

thumb_up_alt 0 like thumb_down_alt 0 dislike
← Prev Question Next Question →

Related questions

Description :

If the field of synchronous motor is under excited, power factor will be?

Answer :

If the field of synchronous motor is under excited, power factor will be lagging.

thumb_up_alt 0 like thumb_down_alt 0 dislike
241 views 1 answer
Description :

The synchronous motor which works on leading power factor and does not drive any mechanical load is called?

Answer :

The synchronous motor which works on leading power factor and does not drive any mechanical load is called synchronous condenser.

thumb_up_alt 0 like thumb_down_alt 0 dislike
84 views 1 answer
Description :

The synchronous motor will develop maximum power when the load angle is?

Answer :

The synchronous motor will develop maximum power when the load angle is 900.

thumb_up_alt 0 like thumb_down_alt 0 dislike
96 views 1 answer
Description :

A synchronous motor has better power factor as compared to that of an equivalent induction motor. This is mainly because?

Answer :

A synchronous motor has better power factor as compared to that of an equivalent induction motor. This is mainly because stator supply is not required to produce magnetic field.

thumb_up_alt 0 like thumb_down_alt 0 dislike
94 views 1 answer
Description :

In a synchronous generator delivering lagging power factor load  (1) the excitation emf leads terminal voltage by the power angle (2) the excitation emf lags terminal voltage by the power angle (3) excitation emf leads the terminal voltage by the power factor angle (4) excitation emf lags the terminal voltage by the power factor angle

Answer :

In a synchronous generator delivering lagging power factor load the excitation emf leads terminal voltage by the power angle

thumb_up_alt 0 like thumb_down_alt 0 dislike
232 views 1 answer
Description :

How can we improve power factor using synchronous motor?

thumb_up_alt 0 like thumb_down_alt 0 dislike
67 views 0 answers
Description :

Answer :

Yes, we can make the power factor of synchronous motor leading by adjusting its excitation.

thumb_up_alt 0 like thumb_down_alt 0 dislike
88 views 1 answer
Description :

If we change the excitation of synchronous machine will it affect on power factor?

Answer :

Yes, If we change the excitation of synchronous machine it will affect on power factor. If the synchronous motor is overexcited then it will have leading power factor and if the motor is underexcited then it will have lagging power factor.

thumb_up_alt 0 like thumb_down_alt 0 dislike
88 views 1 answer
Description :

Answer :

As the load is increased the speed of D.C. shunt motor will reduce slightly.

thumb_up_alt 0 like thumb_down_alt 0 dislike
117 views 1 answer
Description :

Answer :

The standard full-load power factor ratings for synchronous motors are unity or 0.8 leading.

thumb_up_alt 0 like thumb_down_alt 0 dislike
74 views 1 answer
Description :

Answer :

An over excited synchronous motor on noload is known as synchronous condenser.

thumb_up_alt 0 like thumb_down_alt 0 dislike
63 views 1 answer
Description :

The maximum constant load torque under which a synchronous motor will pull into synchronism at rated rotor supply voltage and frequency is known as?

Answer :

The maximum constant load torque under which a synchronous motor will pull into synchronism at rated rotor supply voltage and frequency is known as pull-in torque.

thumb_up_alt 0 like thumb_down_alt 0 dislike
242 views 1 answer
Description :

Answer :

If the synchronous motor, properly synchronised to the supply is running on no load and is having negligible loss then the stator current will be zero.

thumb_up_alt 0 like thumb_down_alt 0 dislike
99 views 1 answer
Description :

Answer :

A synchronous motor running with normal excitation adjusts to load increases essentially by increase in armature current.

thumb_up_alt 0 like thumb_down_alt 0 dislike
114 views 1 answer
Description :

Answer :

The coupling angle or load angle of synchronous motor is defined as the angle between the rotor and the stator poles of opposite polarity.

thumb_up_alt 0 like thumb_down_alt 0 dislike
148 views 1 answer
Description :

In a synchronous motor which losses varies with load?

Answer :

In a synchronous motor, copper losses varies with load.

thumb_up_alt 0 like thumb_down_alt 0 dislike
75 views 1 answer
Description :

Answer :

For power factor correction, synchronous motors operate at no-load and greatly over-excited fields.

thumb_up_alt 0 like thumb_down_alt 0 dislike
89 views 1 answer
Description :

Why synchronous machine is called doubly excited machine?

Answer :

Armature windings of synchronous machines either deliver 3 phase AC or absorb 3 phase AC source,  whereas field windings are energized from DC source. Thus due to presence of AC on armature and DC on field windings, synchronous machines are often referred as doubly excited machines.

thumb_up_alt 0 like thumb_down_alt 0 dislike
3.2k views 2 answers
Description :

Answer :

The power factor of a single phase load can be calculated if the instruments available are three ammeters or three voltmeters.

thumb_up_alt 0 like thumb_down_alt 0 dislike
165 views 2 answers
Description :

The effect of increasing load on a synchronous motor running with normal excitation is (A) Increase both its Ia and power factor. (B) Decrease Ia, but increase power factor. (C) Increase Ia, but decrease power factor (D) Decrease both Ia and power factor.

Answer :

The effect of increasing load on a synchronous motor running with normal excitation is Increase Ia, but decrease power factor

thumb_up_alt 0 like thumb_down_alt 0 dislike
430 views 1 answer
Description :

In synchronous motor, does the winding losses vary with load?

Answer :

No, in the synchronous motor the winding losses do not vary with load.

thumb_up_alt 0 like thumb_down_alt 0 dislike
499 views 1 answer
Description :

The power factor angle and torque angle of a salient pole synchronous generator drawing a current of 1.0 pu from a lagging load are 45o and 15o, respectively. The direct axis and quadrature axis currents, respectively, are (A) 0.5 pu, 0.866 pu (B) 0.866 pu, 0.5 pu (C) 0.707 pu, 0.707 pu (D) 0.5 pu, 0.5 pu

Answer :

The power factor angle and torque angle of a salient pole synchronous generator drawing a current of 1.0 pu from a lagging load are 45o and 15o, respectively. The direct axis and quadrature axis currents, respectively, are 0.866 pu, 0.5 pu

thumb_up_alt 0 like thumb_down_alt 0 dislike
65 views 1 answer
Description :

Answer :

In a distribution system, in order to improve power factor, the synchronous capacitors are installed at the receiving end.

thumb_up_alt 0 like thumb_down_alt 0 dislike
121 views 1 answer
Description :

Can a synchronous condenser improve power factor?

Answer :

Yes, synchronous condenser can improve power factor.

thumb_up_alt 0 like thumb_down_alt 0 dislike
73 views 1 answer
Description :

A transformer has negative voltage regulation when its load power factor is   (1) Zero (2) Unity (3) Leading (4) Lagging

Answer :

Leading

thumb_up_alt 0 like thumb_down_alt 0 dislike
2.0k views 2 answers
Description :

Power station having Load factor = 70%, capacity factor = 50%, used factor = 60%, maximum demand = 20MW then annual energy production is  (1) 122.8 GWh (2) 198.55 GWh (3) 128.2 GWh (4) 188.82 GWh

Answer :

Power station having Load factor = 70%, capacity factor = 50%, used factor = 60%, maximum demand = 20MW then annual energy production is 122.8 GWh

thumb_up_alt 0 like thumb_down_alt 0 dislike
95 views 1 answer
Description :

Answer :

Load factor of a power station is generally less than unity.

thumb_up_alt 0 like thumb_down_alt 0 dislike
58 views 1 answer
Description :

Answer :

Load factor of a power station is defined as average load/maximum demand.

thumb_up_alt 0 like thumb_down_alt 0 dislike
134 views 1 answer
Description :

Minimum voltage regulation occurs when the power factor of the load is?

Answer :

Minimum voltage regulation occurs when the power factor of the load is leading.

thumb_up_alt 0 like thumb_down_alt 0 dislike
146 views 1 answer
Description :

Answer :

When a D.C. series motor is connected to A.C. supply, the power factor will be low because of high inductance of field and armature circuits.

thumb_up_alt 0 like thumb_down_alt 0 dislike
107 views 1 answer
Description :

Answer :

In case of a reluctance motor, when the load is increased so that it cannot maintain synchronous speed the motor will run as induction motor.

thumb_up_alt 0 like thumb_down_alt 0 dislike
97 views 1 answer
Description :

The no-load speed of a single-phase SCR bridge converter fed separately excited dc motor operating at a firing delay angle, α and flux, Φ (A) directly proportional to α and Φ (B) inversely proportional to α and Φ (C) directly proportional to α and inversely proportional to Φ (D) directly proportional to Φ and inversely proportional to α

Answer :

The no-load speed of a single-phase SCR bridge converter fed separately excited dc motor operating at a firing delay angle, α and flux, Φ directly proportional to α and inversely proportional to Φ

thumb_up_alt 0 like thumb_down_alt 0 dislike
129 views 1 answer
Description :

In a synchronous generator if the excitation increased from a low value to normal value, with a fixed load  (A) The armature current increases and the power factor decreases  (B) The armature current decreases and the power factor also decreases  (C) The armature current decreases and the power factor increases but is lagging  (D) The armature current decreases and the power factor increases and is leading

Answer :

In a synchronous generator if the excitation increased from a low value to normal value, with a fixed load The armature current decreases and the power factor increases and is leading

thumb_up_alt 0 like thumb_down_alt 0 dislike
97 views 1 answer
Description :

Answer :

If the field winding of an unloaded salient pole synchronous motor is open circuited, the motor will stop.

thumb_up_alt 0 like thumb_down_alt 0 dislike
133 views 1 answer
Description :

If we change the excitation of synchronous machine will it affect on motor speed?

Answer :

No, If we change the excitation of synchronous machine it will not affect on motor speed.

thumb_up_alt 0 like thumb_down_alt 0 dislike
80 views 1 answer
Description :

A three-phase synchronous motor connected to ac mains is running at full load and unity power factor. lf its shaft load is reduced by half and field current is held constant then its new power factor will be

Answer :

Leading

thumb_up_alt 0 like thumb_down_alt 0 dislike
511 views 2 answers
Description :

Answer :

The increased load during summer months is due to increased use of fans and air conditioners.

thumb_up_alt 0 like thumb_down_alt 0 dislike
42 views 1 answer
Description :

The maximum reluctance power of a salient-pole synchronous motor having direct-axis reactance, 1.0 pu and quadrature-axis reactance, 0.5 pu, and input voltage, 1.0 pu is (A) 0.25 pu (B) 0.5 pu (C) 1.0 pu (D) 1.5 pu

Answer :

The maximum reluctance power of a salient-pole synchronous motor having direct-axis reactance, 1.0 pu and quadrature-axis reactance, 0.5 pu, and input voltage, 1.0 pu is 0.5 pu

thumb_up_alt 0 like thumb_down_alt 0 dislike
83 views 1 answer
Description :

Answer :

The power factor of a single-phase induction motor is usually lagging.

thumb_up_alt 0 like thumb_down_alt 0 dislike
128 views 1 answer
Description :

Answer :

An induction motor has relatively high power factor at near full load.

thumb_up_alt 0 like thumb_down_alt 0 dislike
68 views 1 answer
Description :

At which time power factor of the induction motor is low?

Answer :

The power factor of the inducction motor is low at the time of starting as compare to while the induction motor is running.

thumb_up_alt 0 like thumb_down_alt 0 dislike
141 views 1 answer
Description :

Answer :

The efficiency of a properly designed synchronous motor will usually fall in range 85 to 95%.

thumb_up_alt 0 like thumb_down_alt 0 dislike
64 views 1 answer
Description :

Answer :

In case one phase of a three-phase synchronous motor is short-circuited the motor will not start.

thumb_up_alt 0 like thumb_down_alt 0 dislike
214 views 1 answer
Description :

The maximum torque which a synchronous motor will develop at rest for any angular position of the rotor, at rated stator supply voltage and frequency, is known as?

thumb_up_alt 0 like thumb_down_alt 0 dislike
93 views 0 answers
Description :

what will happen when excitation of an unloaded salient pole synchronous motor suddenly gets disconnected?

Answer :

When excitation of an unloaded salient pole synchronous motor suddenly gets disconnected the motor will stop.

thumb_up_alt 0 like thumb_down_alt 0 dislike
304 views 1 answer
Description :

Three phase synchronous motor will have how many sliprings?

Answer :

Three phase synchronous motor will have two sliprings.

thumb_up_alt 0 like thumb_down_alt 0 dislike
78 views 1 answer
Description :

A separately excited dc motor operating in first quadrant is fed from 3-phase semi -converter free -wheeling diode is open circuited, then the motor :  (A) can be operated in first quadrant (B) can be operated in first & second quadrants (C) can be operated in first & fourth quadrants (D) cannot be operated

Answer :

A separately excited dc motor operating in first quadrant is fed from 3-phase semi -converter free -wheeling diode is open circuited, then the motor : can be operated in first & fourth quadrants

thumb_up_alt 0 like thumb_down_alt 0 dislike
198 views 1 answer
Description :

Separately Excited DC motor

Answer :

Separately Excited DC motor

thumb_up_alt 0 like thumb_down_alt 0 dislike
310 views 2 answers
Description :

Answer :

The steady state stability of the power system can be increased by connecting lines in parallel.

thumb_up_alt 0 like thumb_down_alt 0 dislike
102 views 1 answer
Description :

Answer :

Slip-rings in a synchronous motor carry direct current.

thumb_up_alt 0 like thumb_down_alt 0 dislike
87 views 1 answer
editAsk a Question
...