How can power loss be reduced?
Why high voltage can reduce power loss?
when voltage has increased due to reduced current flow, thus power loss given by ( I^2R) will be low due to reduced current(I^2) provided that resistance (R) is constant.
In a circuit containing R, L and C, power loss can take place in?
In a circuit containing R, L and C, power loss can take place in R only.
The power loss is an important factor for the design of transmission line.
Calculate the value of equivalent capacitance of the combination.
Calculate the value of equivalent capacitance of the combination
Calculate these complex numbers and express your results in rectangular form
How do you power an Arduino?
How do you measure power factor?
P= 1.83*V*I*[email protected] where P is power V is voltage I is current COS @ is P.F [email protected]= P/(1.83*V*I) in other way cos @ = true power/apparent power
How do you find power in a circuit?
Power can be find in a circuit by the means of meters .if an individual want to check for a power in a circuit he/she Calabria the meters on a high voltage range and put the meters Lee in parallel with the circuit he /she will know the amount of power within that circuit .
Corona is nothing but the ionization of surrounding air around the conductor which produces hissing noise,
State the factors affecting hysteresis loss.
i) Flux density ii) Frequency iii) Volume of the magnetic material iv) Nature of magnetic material
A 40 kVA transformer has a core loss of 400 W and a full load copper loss of 800 W. The proportion of full load at maximum efficiency is
A 40 kVA transformer has a core loss of 400 W and a full load copper loss of 800 W. The proportion of full load at maximum efficiency is 0.707
The eddy current loss in a dc generator is 400 W at 40 Hz frequency of reversal and constant flux density. When frequency is increased to 50 Hz., eddy current loss is : (A) 256 W (B) 320 W (C) 500 W (D) 625 W
The eddy current loss in a dc generator is 400 W at 40 Hz frequency of reversal and constant flux density. When frequency is increased to 50 Hz., eddy current loss is : 625 W
At full -load of a transformer, the iron loss and copper loss are 3000 W and 4000 W respectively. Then total loss at maximum efficiency is : (A) 7000 W (B) 6000 W (C) 8000 W (D) 4000 W
At full -load of a transformer, the iron loss and copper loss are 3000 W and 4000 W respectively. Then total loss at maximum efficiency is : 6000 W
Corona loss in transmission lines can be reduced by (A) using small diameter conductors (B) using bundled conductors (C) using less spacing between conductors (D) increasing the transmission line voltage
Corona loss in transmission lines can be reduced by using bundled conductors
Dielectric loss in a capacitor is best measured by (A) Wien Bridge (B) Schering Bridge (C) Anderson Bridge (D) Heaviside-Campbell Equal Ratio Bridge
Dielectric loss in a capacitor is best measured by Schering Bridge
A ferrite core has less eddy current loss than an iron core because?
A ferrite core has less eddy current loss than an iron core because ferrites have high hysteresis.
In a magnetic material hysteresis loss takes place primarily due to?
In a magnetic material hysteresis loss takes place primarily due to it high retentivity.
In a loss-free R-L-C circuit the transient current is?
In a loss-free R-L-C circuit the transient current is sinusoidal.
If the current in a capacitor leads the voltage by 80°, the loss angle of the capacitor is 10°.
In a D.C. machine stray loss is the sum of iron loss and mechanical loss.
If the synchronous motor, properly synchronised to the supply is running on no load and is having negligible loss then the stator current will be zero.
In an actual transformer the iron loss remains practically constant from no load to full load because core flux remains practically constant.
If the supply frequency to the transformer is increased, the iron loss will increase.
Iron loss of a transformer can be measured by low power factor wattmeter.
What is the difference between eddy current and hysteresis loss?
Loss occurred by magnetising and demagnetising process is called histerisis loss and the current flowed due to the magnetic field produced by the electric field applied is called eddy current losses
Explain hysteresis loss, eddy current loss and skin effect limitations with reference to magnetic material.
Hysteresis loss: Hysteresis loss is a loss which occurs due to the friction of magnetic domain due to the change in magnetic field in ferromagnetic material like iron. Hysteresis loss causes power loss ... loss in transformer is given by, We=Kef2Kf2Bm2watts Skin effect limitations:
What can you do to prevent a power surge?
How often do power surges occur?
A Unified Power Flow Controller (FACTS controller) is a voltage source converter based (A) Inter-phase power controller (B) Static Compensator (C) Combination of series and shunt compensators (D) Solid-state series compensator
A Unified Power Flow Controller (FACTS controller) is a voltage source converter based Combination of series and shunt compensators
In voltage source converter based HVDC transmission system the active power is controlled by changing (A) phase angle of the converter ac input voltage (B) supply frequency of the converter ac input voltage (C) magnitude of the converter ac input voltage (D) DC voltage at the inverter terminals
In voltage source converter based HVDC transmission system the active power is controlled by changing phase angle of the converter ac input voltage
Is more power dissipated in series or parallel?
What is a safe distance from power lines?
Why high voltage is used in power transmission?
The primary reason that power is transmitted at high voltages is to increase efficiency. ... The lower current that accompanies high voltage transmissionreduces resistance in the conductors aselectricity flows ... This means that thin, light-weight wires can beused in long-distance transmission.
How do you fix voltage drop?
To protect the power transformer (Y-Y with neutral grounded) against fault, what type of connection do the CTs have ?
To protect the power transformer (Y-Y with neutral grounded) against fault, what type of connection do the CTs have ? Δ-Δ connection
Why do we need to correct power factor?
Calculate the power loss, if power generated by two plants are P1=50 MW and P2 =40 MW and the loss coefficients are B11=0.001, B22=0.0025 and B12=-0.0005. (A) 4.5 MW (B) 5.5 MW (C) 6.5 MW (D) 8.5 MW
A
Can you have a power factor greater than 1?
We cannot have power factor greater than 1. As it is a measure of cosine of angle between voltage and current.
Briefly explain how the power factor of an inductive circuit can be improved.
As we know that power factor should be corrected to ensure that the current supplied is cost friendly. Meaning the power factor should be around one but not greater than one(0.8-0.9) in a ... an inductive circuit due to the inductive reactance which oppose the change of current in the ac circuit.
Discuss how power factor tariff results into energy conservation.
Power factor tariff results into energy conservation: i) Applying incentives and penalties according to power factor is an effective way, which enables consumer to improve power factor so that he can ... finally leads to reduction in the current drawn by the load and helps for energy conservation.
How many volts does it take to power an Arduino?
5volts is enough to supply the Arduino.
How can we improve power factor using synchronous motor?
How many watts does a power plant produce?
How much electricity is produced by a power plant?
How much power does an Arduino use?
How many volts are in the power lines?
How does electricity get from the power plant to your home?
Electricity gets into my home due to potential diffrence created between the live wire and neutral wire.
How to make power bank from laptop battery cells?
You can make the power bank from laptop battery cells. Things you need to make power bank from laptop battery cells: Laptop battery cells (about 6 in parallel) Universal Dual USB 5V 1A 2.1A New Hot ... If you have any doubt ask it. Thanks...