What is an insulation resistance test?

Related questions

Description : What is the lowest acceptable insulation resistance for a cable?

Answer : Meggar is an instrument which measures the insulation resistance of an electric circuit relative to earth and one another.

Description : Write measures to be taken to maintain the insulation resistance of electrical machines to healthy levels.

Description : Name the method used to measure following resistances:- (i) Low resistance (ii) Medium resistance (iii) Insulation resistance (iv) Earth resistance.

Answer : Following are the methods used to measure resistances:-  (i) Low resistance: 1.Voltmeter-Ammeter Method 2. Kelvin's Double bridge Method  (ii) Medium resistance: 1.Voltmeter-Ammeter Method 2. ... of Charge Method  (iv) Earth resistance : 1. Fall of Potential Method 2. Earth tester

Description : If the insulation resistance of a cable of length 10 km is 1 mega ohm, its insulation resistance for 50 km length will be

Answer : If the insulation resistance of a cable of length 10 km is 1 mega ohm, its insulation resistance for 50 km length will be 0.2 mega ohm

Description : When measuring insulation resistance of cables using d.c. source, the galvanometer used should be initially short circuited because  (A) Cables have a low value of capacitance which draws a high ... high value of charging current (D) Cables have a low value of capacitance and initial resistance

Answer : When measuring insulation resistance of cables using d.c. source, the galvanometer used should be initially short circuited because Cables have a high value of capacitance which draws a high value of charging current

Answer : Insulation resistance of high voltage circuit breakers is more than 100 mega ohms.

Description : What do you mean by insulation coordination?

Description : What is double or reinforced insulation?

Description : What is basic insulation level?

Description : What is a high voltage test?

Description : Why high voltage test is done?

Description : The thickness of insulation provided on the conductor depends on?

Answer : The thickness of insulation provided on the conductor depends on the magnitude of voltage on the conductor.

Description : The insulation on a current carrying conductor is provided?

Answer : The insulation on a current carrying conductor is provided to prevent leakage of current, to prevent shock.

Description : Slip test is performed to determine :  (A) Slip in an induction motor  (B) Xd and Xq in a salient pole alternator  (C) Synchronous impedance in an alternator  (D) Positive and negative sequence impedances of an alternator

Answer : Slip test is performed to determine :  Xd and Xq in a salient pole alternator 

Description : An open-circuit test on a transformer is conducted primarily to measure?

Answer : The open-circuit test in a transformer is used to measure

Description : How do you test an SCR?

Description : What is test bench? Write its applications

Answer : Test Bench: A test bench is used to verify the functionality of the design. We need to stimulate our designs in order to test their functionality. Stimulus in a real system is from an ... the entity under test and to collect output responses. 6. To compare output responses with expected values.

Answer : In short circuit test of transformer the low voltage side is short circuited . On high voltage side the voltmeter is connected in parallel and ammeter in series and also a wattmeter is ... circuit test is done for determining impedance and losses. In this test iron losses is neglected.

Description : Polarity Test of Transformer

Answer : .embed-container { position: relative; padding-bottom: 56.25%; height: 0; overflow: hidden; max-width: 100%; } .embed-container iframe, .embed-container object, .embed-container embed { position: absolute; top: 0; left: 0; width: 100%; height: 100%; }

Description : Explain the procedure to perform Short Circuit test on single phase transformer with circuit diagram.

Description : With the help of neat diagram, describe the procedure to carry out phasing out test on a 3 phase transformer. Also state the purpose of conducting this test on 3 phase transformer.

Answer : i) This test is carried out on 3-ph transformer to identify primary & secondary winding belonging to the same phase. ii) As shown in fig above all primary & secondary phases ... of this test is to check the respective phases of primary & secondary windings in 3-ph transformer

Description : Explain the open delta (delta-delta) test on transformer.

Description : DC motor brake test numerical

Answer : .embed-container { position: relative; padding-bottom: 56.25%; height: 0; overflow: hidden; max-width: 100%; } .embed-container iframe, .embed-container object, .embed-container embed { position: absolute; top: 0; left: 0; width: 100%; height: 100%; }

Description : Brake test on DC series motor

Answer : .embed-container { position: relative; padding-bottom: 56.25%; height: 0; overflow: hidden; max-width: 100%; } .embed-container iframe, .embed-container object, .embed-container embed { position: absolute; top: 0; left: 0; width: 100%; height: 100%; }

Description : Explain the need and steps to conduct the reduced voltage running up test on the three phase induction motor.

Description : Why phasing out and polarity test is carried out on three phase transformer?

Answer : The phasing out test is carried out to identify the windings (primary and secondary) of corresponding phase of the three phase transformer. The polarity test is carried out to identify the ... identical polarity of the primary and secondary windings of each phase of the three phase transformer.

Description : If a 5-bus test system contains 6 transmission lines and one transformer, how many non-zero elements are there in the system Y-bus ? (A) 25 (B) 12 (C) 11 (D) 19

Answer : If a 5-bus test system contains 6 transmission lines and one transformer, 19 non-zero elements are there in the system Y-bus.

Answer : Murray loop test can be used for location of both the ground fault and the short-circuit fault.

Answer : Hopkinson's test on D.C. machines is conducted at full-load.

Answer : The duration of sudden short-circuit test on a synchronous motor is usually about one second.

Description : During open circuit test of a transformer?

Answer : During open circuit test of a transformer primary is supplied rated voltage.

Answer : Short circuit test on transformers is conducted to determine copper losses.

Description : A no-load test is performed on a transformer to determine?

Answer : A no-load test is performed on a transformer to determine magnetizing current and loss.

Description : Sumpner's test is conducted on transformer to determine?

Answer : Sumpner's test is conducted on transformer to determine temprature.

Description : How do you test a capacitor with a multimeter?

Description : How do we test a diode?

Description : How do you test a triac?

Description : How does the resistance of a conductor compare to that of an insulator?

Answer : The resistance of a conductor can be significantly lower than the resistance of an insulator, depending on each material's atomic properties.

Description : We connected a 35V dc supply to a resistance of 600 Ohm in series with an unknown resistance R.A. voltmeter having a resistance of 1.2 kOhm is connected across 600 Ohm resistance and read 5v. The value of resistance R will be

Answer : We connected a 35V dc supply to a resistance of 600 Ohm in series with an unknown resistance R.A. voltmeter having a resistance of 1.2 kOhm is connected across 600 Ohm resistance and read 5v. The value of resistance R will be 2.4 kOhm

Description : A PMMC instrument has FSD of 100 μA and a coil resistance of 1 kΩ. To convert the instrument into an ammeter with full scale deflection of 100 mA, the required shunt resistance is (A) 1 Ω (B) 1.001 Ω (C) 0.5 Ω (D) 10 Ω

Answer : A PMMC instrument has FSD of 100 μA and a coil resistance of 1 kΩ. To convert the instrument into an ammeter with full scale deflection of 100 mA, the required shunt resistance is 1.001 Ω

Description : When an alternating current passes through an ohmic resistance the electrical power converted into heat is?

Answer : When an alternating current passes through an ohmic resistance the electrical power converted into heat is true power.

Description : An A.C. voltage is impressed across a pure resistance of 3.5 ohms in parallel with a pure inductance of impedance of 3.5 ohms?

Answer : An A.C. voltage is impressed across a pure resistance of 3.5 ohms in parallel with a pure inductance of impedance of 3.5 ohms, both resistance and inductance carry equal currents.

Description : The effective resistance of an iron-cored choke working on ordinary supply frequency is more than its true resistance because of?

Answer : The effective resistance of an iron-cored choke working on ordinary supply frequency is more than its true resistance because of iron loss in core.

Description : What do you mean by exciting resistance and exciting reactance?

Description : what is equivalent resistance when four 4 Ohm resistors are connected in i) series ii) parallel

Answer : equivalent resistance

← Prev Question Next Question →
editAsk a Question
...