How do you measure power factor?
thumb_up_alt 0 like thumb_down_alt 0 dislike
79 views

1 Answer

    P= 1.83*V*I*[email protected] where P is power           V is voltage            I is current           COS @ is P.F [email protected]= P/(1.83*V*I)  in other way cos @ = true power/apparent power
thumb_up_alt 0 like thumb_down_alt 0 dislike
← Prev Question Next Question →

Related questions

Description :

Why do we need to correct power factor?

thumb_up_alt 0 like thumb_down_alt 0 dislike
57 views 0 answers
Description :

Can you have a power factor greater than 1?

Answer :

We cannot have power factor greater than 1. As it is a measure of cosine of angle between voltage and current. 

thumb_up_alt 0 like thumb_down_alt 0 dislike
110 views 1 answer
Description :

What is the use of power factor correction?

thumb_up_alt 0 like thumb_down_alt 0 dislike
81 views 0 answers
Description :

What is the best power factor?

Answer :

It is unity power factor but difficult to achieve in dynamic loads

thumb_up_alt 0 like thumb_down_alt 0 dislike
78 views 1 answer
Description :

What is power factor angle?

thumb_up_alt 0 like thumb_down_alt 0 dislike
62 views 0 answers
Description :

What is the advantage of high power factor?

Answer :

Reduced copper losses Smaller conductor size Improve voltage regulation Increase system capability Less energy bill

thumb_up_alt 0 like thumb_down_alt 0 dislike
81 views 2 answers
Description :

Explain the term reactive power. Why it is sometimes essential to measure reactive power?

Answer :

Reactive power: The reactive power (Q) is defined as the product of voltage(V), current (I) and sine of angle between voltage(V) and current( I) Therefore Reactive power Q = V I ... power so that corrective measures can be taken accordingly to maintain systems power factor near to the unity.

thumb_up_alt 0 like thumb_down_alt 0 dislike
58 views 1 answer
Description :

How do you measure the speed of a motor?

thumb_up_alt 0 like thumb_down_alt 0 dislike
40 views 0 answers
Description :

Briefly explain how the power factor of an inductive circuit can be improved.

Answer :

As we know that power factor should be corrected to ensure that the current supplied is cost friendly. Meaning the power factor should be around one but not greater than one(0.8-0.9) in a ... an inductive circuit due to the inductive reactance which oppose the change of current in the ac circuit. 

thumb_up_alt 0 like thumb_down_alt 0 dislike
110 views 1 answer
Description :

Discuss how power factor tariff results into energy conservation.

Answer :

Power factor tariff results into energy conservation: i) Applying incentives and penalties according to power factor is an effective way, which enables consumer to improve power factor so that he can ... finally leads to reduction in the current drawn by the load and helps for energy conservation.

thumb_up_alt 0 like thumb_down_alt 0 dislike
2.6k views 1 answer
Description :

How can we improve power factor using synchronous motor?

thumb_up_alt 0 like thumb_down_alt 0 dislike
66 views 0 answers
Description :

How does a capacitor improve power factor?

Answer :

Every circuit are usually more inductive than capacitive.it means that the current lags by voltage at small angle.hence we have to compensate this situation so we use Capacitor then this lag is compensate ... angle becomes low and the value of cos(phase angle) is increase and hence power also max.

thumb_up_alt 4 like thumb_down_alt 0 dislike
143 views 1 answer
Description :

State the effects of low power factor on efficiency and voltage regulation of short transmission lines. 

Answer :

i) Effect of Low power factor on efficiency:- When power factor of load reduces current drawn by transmission line increases so copper losses in transmission line increases, hence transmission ... increases, so voltage drop in transmission line increases so regulation increases. (Become Poor) 

thumb_up_alt 0 like thumb_down_alt 0 dislike
109 views 1 answer
Description :

What is the value of capacitance required to improve power factor from 0.7 to 0.9. Given that: Real power = 50 W Vrms of the source = 120 Frequency = 50 Hz   #powerfactor

thumb_up_alt 0 like thumb_down_alt 0 dislike
188 views 0 answers
Description :

Why capacitors are used to improve power factor?

Answer :

 Capacitors generate reactive power instead of that drawn from source which is required by inductive loads.so it reduce the reactive current which is drawn from source to be drawn from capacitor.This control in Electric bills cost.

thumb_up_alt 1 like thumb_down_alt 0 dislike
134 views 3 answers
Description :

Draw and explain bulk correction method for power factor & control.

Answer :

Bulk correction method for power factor & control: i) Here individual starter controls the capacitors located at distribution panel. ii) Centralized compensation is employed in large industrial plants where many ... capacitor units in steps to maintain P.F. more than preset limit (0.95). 

thumb_up_alt 0 like thumb_down_alt 0 dislike
98 views 1 answer
Description :

State the incentives and penalties related with power factor tariff.

Answer :

Incentives and penalties related with power factor tariff: In addition to basic tariff (Maximum Demand Tariff / KVA Maximum Demand Tariff / Load factor tariff) the tariff in which P.F. of ... industrial consumer/H.T/ commercial consumers with contract demand above 80 kw/ 100Kva/107 hp consumer.

thumb_up_alt 0 like thumb_down_alt 0 dislike
61 views 1 answer
Description :

With a neat sketch explain working of 1 phase dynamometer type power factor meter.

Answer :

Working of 1 phase dynamometer type power factor meter : The current coil is connected in series with load. Two pressure coils marked as A and B are connected across the supply terminals ... becomes stationary and the pointer shows steady deflection corresponding to the power factor of the load. 

thumb_up_alt 0 like thumb_down_alt 0 dislike
103 views 1 answer
Description :

State the significance of power factor.

Answer :

Significance of power factor:-  1. Cosine of angle between voltage & current in a circuit is called power factor. 2. It is a measure of the real power in a circuit. 3. Inductive & ... KVA rating equipment 5. Greater conductor size 6. CosØ = R/Z  CosØ= Active Power/ Apparent Power 

thumb_up_alt 0 like thumb_down_alt 0 dislike
40 views 1 answer
Description :

A transformer has negative voltage regulation when its load power factor is   (1) Zero (2) Unity (3) Leading (4) Lagging

Answer :

Leading

thumb_up_alt 0 like thumb_down_alt 0 dislike
1.9k views 2 answers
Description :

The power factor of dielectric :  (A) is a function of temperature of the dielectric only (B) depends only on voltage stress to which the dielectric is stressed (C) always constant (D) both (A) and (B)

Answer :

The power factor of dielectric :  (A) is a function of temperature of the dielectric only (B) depends only on voltage stress to which the dielectric is stressed (C) always constant (D) both (A) and (B)

thumb_up_alt 0 like thumb_down_alt 0 dislike
66 views 1 answer
Description :

Power station having Load factor = 70%, capacity factor = 50%, used factor = 60%, maximum demand = 20MW then annual energy production is  (1) 122.8 GWh (2) 198.55 GWh (3) 128.2 GWh (4) 188.82 GWh

Answer :

Power station having Load factor = 70%, capacity factor = 50%, used factor = 60%, maximum demand = 20MW then annual energy production is 122.8 GWh

thumb_up_alt 0 like thumb_down_alt 0 dislike
91 views 1 answer
Description :

In a synchronous generator delivering lagging power factor load  (1) the excitation emf leads terminal voltage by the power angle (2) the excitation emf lags terminal voltage by the power angle (3) excitation emf leads the terminal voltage by the power factor angle (4) excitation emf lags the terminal voltage by the power factor angle

Answer :

In a synchronous generator delivering lagging power factor load the excitation emf leads terminal voltage by the power angle

thumb_up_alt 0 like thumb_down_alt 0 dislike
228 views 1 answer
Description :

What is the power factor when a single phase watt meter operating on 200 V and 5 A for 5 hours makes 2016 revolutions and the meter constant in revolution is 420? A) 0.04 B) 1.04 C) 0.96 D) None of these

Answer :

What is the power factor when a single phase watt meter operating on 200 V and 5 A for 5 hours makes 2016 revolutions and the meter constant in revolution is 420? A) 0.04 B) 1.04 C) 0.96 D) None of these

thumb_up_alt 0 like thumb_down_alt 0 dislike
147 views 1 answer
Description :

The benefit of power factor correction in a power system is (A) lower power consumption (B) increased demand charge (C) reduced load carrying capabilities in existing lines (D) reduced voltage profile

Answer :

The benefit of power factor correction in a power system is lower power consumption

thumb_up_alt 0 like thumb_down_alt 0 dislike
74 views 1 answer
Description :

The power factor angle and torque angle of a salient pole synchronous generator drawing a current of 1.0 pu from a lagging load are 45o and 15o, respectively. The direct axis and quadrature axis currents, respectively, are (A) 0.5 pu, 0.866 pu (B) 0.866 pu, 0.5 pu (C) 0.707 pu, 0.707 pu (D) 0.5 pu, 0.5 pu

Answer :

The power factor angle and torque angle of a salient pole synchronous generator drawing a current of 1.0 pu from a lagging load are 45o and 15o, respectively. The direct axis and quadrature axis currents, respectively, are 0.866 pu, 0.5 pu

thumb_up_alt 0 like thumb_down_alt 0 dislike
62 views 1 answer
Description :

The power factor of a D.C. circuit is always?

Answer :

The power factor of a D.C. circuit is always unity.

thumb_up_alt 0 like thumb_down_alt 0 dislike
176 views 1 answer
Description :

The ratio of active power to apparent power is known as____ factor.

Answer :

The ratio of active power to apparent power is known as power factor.

thumb_up_alt 0 like thumb_down_alt 0 dislike
332 views 1 answer
Description :

The input of an A.C. circuit having power factor of 0.8 lagging is 40 kVA The power drawn by the circuit is?

Answer :

The input of an A.C. circuit having power factor of 0.8 lagging is 40 kVA The power drawn by the circuit is 32 kW.

thumb_up_alt 0 like thumb_down_alt 0 dislike
341 views 1 answer
Description :

Power factor of electric bulb is?

Answer :

Power factor of electric bulb is unity.

thumb_up_alt 0 like thumb_down_alt 0 dislike
76 views 1 answer
Description :

The power factor at resonance in R-L- C parallel circuit is?

Answer :

since a rlc circuit at resonance behaves like a pure resistive circuit, i.e there is no phase difference between current and voltage, hence the power factor is unity.

thumb_up_alt 0 like thumb_down_alt 0 dislike
317 views 2 answers
Description :

Power factor of the system is kept high?

Answer :

Power factor of the system is kept high to reduce line losses, to maximise the utilization of the capacities of generators, lines and transformers, to reduce voltage regulation of the line.

thumb_up_alt 0 like thumb_down_alt 0 dislike
97 views 1 answer
Description :

Power factor of an inductive circuit is usually improved by connecting capacitor to it in?

Answer :

Power factor of an inductive circuit is usually improved by connecting capacitor to it in parallel.

thumb_up_alt 0 like thumb_down_alt 0 dislike
182 views 1 answer
Description :

Capacitors for power factor correction are rated in?

Answer :

Capacitors for power factor correction are rated in kVAR.

thumb_up_alt 0 like thumb_down_alt 0 dislike
63 views 1 answer
Description :

Poor power factor?

Answer :

Poor power factor reduces load handling capability of electrical system, results in more power losses in the electrical system, overloads alternators, transformers and distribution lines, results in more voltage drop in the line.

thumb_up_alt 0 like thumb_down_alt 0 dislike
48 views 1 answer
Description :

Power factor of an electrical circuit is equal to?

Answer :

Power factor of an electrical circuit is equal to R/Z, cosine of phase angle difference between current and voltage, kW/kVA.

thumb_up_alt 0 like thumb_down_alt 0 dislike
224 views 1 answer
Description :

Answer :

The power factor of a single phase load can be calculated if the instruments available are three ammeters or three voltmeters.

thumb_up_alt 0 like thumb_down_alt 0 dislike
164 views 2 answers
Description :

Answer :

In a dynamometer 3-phase power factor meter, the planes of the two moving coils are at 120°.

thumb_up_alt 0 like thumb_down_alt 0 dislike
89 views 1 answer
Description :

Answer :

In a single phase power factor meter the phase difference between the currents in the two pressure coils is exactly 90°.

thumb_up_alt 0 like thumb_down_alt 0 dislike
196 views 1 answer
Description :

Answer :

The two pressure coils of a single phase power factor meter have the same dimensions and the same number of turns.

thumb_up_alt 0 like thumb_down_alt 0 dislike
87 views 1 answer
Description :

Answer :

A power factor meter has one current circuit and two pressure circuits.

thumb_up_alt 0 like thumb_down_alt 0 dislike
54 views 1 answer
Description :

Answer :

In a low power factor wattmeter the compensating coil is connected in series with pressure coil.

thumb_up_alt 0 like thumb_down_alt 0 dislike
343 views 1 answer
Description :

Answer :

In a low power factor wattmeter the pressure coil is connected to the load side of the current coil.

thumb_up_alt 0 like thumb_down_alt 0 dislike
179 views 1 answer
Description :

Answer :

When a D.C. series motor is connected to A.C. supply, the power factor will be low because of high inductance of field and armature circuits.

thumb_up_alt 0 like thumb_down_alt 0 dislike
105 views 1 answer
Description :

Answer :

The power factor of a single-phase induction motor is usually lagging.

thumb_up_alt 0 like thumb_down_alt 0 dislike
121 views 1 answer
Description :

A synchronous motor has better power factor as compared to that of an equivalent induction motor. This is mainly because?

Answer :

A synchronous motor has better power factor as compared to that of an equivalent induction motor. This is mainly because stator supply is not required to produce magnetic field.

thumb_up_alt 0 like thumb_down_alt 0 dislike
93 views 1 answer
Description :

Answer :

The standard full-load power factor ratings for synchronous motors are unity or 0.8 leading.

thumb_up_alt 0 like thumb_down_alt 0 dislike
71 views 1 answer
Description :

Answer :

For power factor correction, synchronous motors operate at no-load and greatly over-excited fields.

thumb_up_alt 0 like thumb_down_alt 0 dislike
86 views 1 answer
Description :

Answer :

An induction motor has relatively high power factor at near full load.

thumb_up_alt 0 like thumb_down_alt 0 dislike
67 views 1 answer
Description :

Answer :

In a distribution system, in order to improve power factor, the synchronous capacitors are installed at the receiving end.

thumb_up_alt 0 like thumb_down_alt 0 dislike
120 views 1 answer
editAsk a Question
...