In synchronous motor, does the winding losses vary with load?

1 Answer

No, in the synchronous motor the winding losses do not vary with load.

thumb_up_alt 0 like thumb_down_alt 0 dislike

Related questions

Description : In a synchronous motor which losses varies with load?

Answer : In a synchronous motor, copper losses varies with load.

Description : Damper winding in a synchronous motor

Answer : Damper winding in a synchronous motor Serves to start the motor.

Answer : Centrifugal switch disconnects the auxiliary winding of the motor at about 70 to 80 percent of synchronous speed.

Description : The effect of increasing load on a synchronous motor running with normal excitation is (A) Increase both its Ia and power factor. (B) Decrease Ia, but increase power factor. (C) Increase Ia, but decrease power factor (D) Decrease both Ia and power factor.

Answer : The effect of increasing load on a synchronous motor running with normal excitation is Increase Ia, but decrease power factor

Description : The damping winding in synchronous motor is generally used to?

Answer : The damping winding in synchronous motor is generally used to provide starting torque and prevent hunting.

Answer : If the field winding of an unloaded salient pole synchronous motor is open circuited, the motor will stop.

Description : The synchronous motor which works on leading power factor and does not drive any mechanical load is called?

Answer : The synchronous motor which works on leading power factor and does not drive any mechanical load is called synchronous condenser.

Answer : A synchronous motor running with normal excitation adjusts to load increases essentially by increase in armature current.

Description : The maximum constant load torque under which a synchronous motor will pull into synchronism at rated rotor supply voltage and frequency is known as?

Answer : The maximum constant load torque under which a synchronous motor will pull into synchronism at rated rotor supply voltage and frequency is known as pull-in torque.

Answer : The coupling angle or load angle of synchronous motor is defined as the angle between the rotor and the stator poles of opposite polarity.

Answer : If the synchronous motor, properly synchronised to the supply is running on no load and is having negligible loss then the stator current will be zero.

Description : If the load of the normally excited synchronous motor is increased the power factor will?

Answer : If the load of the normally excited synchronous motor is increased the power factor will become lagging.

Description : The synchronous motor will develop maximum power when the load angle is?

Answer : The synchronous motor will develop maximum power when the load angle is 900.

Description : Damper winding is provided in 3 phase synchronous motors to :

Answer : Damper winding is provided in 3 phase synchronous motors to : provide starting torque and prevent hunting

Description : In a synchronous generator if the excitation increased from a low value to normal value, with a fixed load  (A) The armature current increases and the power factor decreases  (B) The armature ... but is lagging  (D) The armature current decreases and the power factor increases and is leading

Answer : In a synchronous generator if the excitation increased from a low value to normal value, with a fixed load The armature current decreases and the power factor increases and is leading

Answer : In case of a reluctance motor, when the load is increased so that it cannot maintain synchronous speed the motor will run as induction motor.

Description : A three-phase synchronous motor connected to ac mains is running at full load and unity power factor. lf its shaft load is reduced by half and field current is held constant then its new power factor will be

Answer : Leading

Description : In a given transformer for a given applied voltage, losses which remain constant irrespective of load changes are?

Answer : In a given transformer for a given applied voltage, losses which remain constant irrespective of load changes are hysteresis and eddy current losses.

Description : In a synchronous generator delivering lagging power factor load  (1) the excitation emf leads terminal voltage by the power angle (2) the excitation emf lags terminal voltage by the power angle (3) ... by the power factor angle (4) excitation emf lags the terminal voltage by the power factor angle

Answer : In a synchronous generator delivering lagging power factor load the excitation emf leads terminal voltage by the power angle

Answer : If the centrifugal switch does not open at 70 to 80 percent of synchronous speed of motor, it would result in damage to the starting winding.

Answer : The starting winding of a single-phase motor is placed in stator.

Answer : If starting winding of a single-phase induction motor is left in the circuit, it will draw excessive current and overheat.

Answer : The purpose of stator winding in the compensated repulsion motor is to improve power factor and provide better speed regulation.

Answer : In split phase motor main winding is of thick wire placed at the bottom of the slots.

Description : A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is

Answer : A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is 36 Ohm

Answer : Starting winding of a single phase motor of a refrigerator is disconnected from the circuit by means of a magnetic relay.

Description : In DC motor iron losses are occurred in?

Answer : In DC motor iron losses are occurred in the armature.

Description : The maximum reluctance power of a salient-pole synchronous motor having direct-axis reactance, 1.0 pu and quadrature-axis reactance, 0.5 pu, and input voltage, 1.0 pu is (A) 0.25 pu (B) 0.5 pu (C) 1.0 pu (D) 1.5 pu

Answer : The maximum reluctance power of a salient-pole synchronous motor having direct-axis reactance, 1.0 pu and quadrature-axis reactance, 0.5 pu, and input voltage, 1.0 pu is 0.5 pu

Description : Why synchronous motor Cannot start itself?

Description : How can we improve power factor using synchronous motor?

Description : What is the principle of synchronous motor?

Description : What is the use of synchronous motor?

Description : Why the speed of synchronous motor is constant?

Answer : Yes, we can make the power factor of synchronous motor leading by adjusting its excitation.

Description : what is the difference between synchronous and asynchronous motor?

Answer : Asynchronous motors and syncrouns motor are called as dc machines.  and also syncrouns motor called as induction motor. Asynonymous motor as are rotates with constant speed we not able to operate . ... It is able to operate. These are a small difference between syncrouns and asynchronous motors. 

Description : The running winding of a single phase motor on testing with meggar is found to be ground. Most probable location of the ground will be?

Answer : The running winding of a single phase motor on testing with meggar is found to be ground. Most probable location of the ground will be at the slot edge where coil enters or comes out of the slot.

Description : A 240 V, dc shunt motor draws 15 A while supplying the rated load at a speed of 80 rad/s. The armature resistance is 0.5 W and the field winding resistance is 80 W. The net Voltage across armature resistance at the time of plugging will be

Answer : A 240 V, dc shunt motor draws 15 A while supplying the rated load at a speed of 80 rad/s. The armature resistance is 0.5 W and the field winding resistance is 80 W. The net Voltage across armature resistance at the time of plugging will be 474 V

Answer : As the load is increased the speed of D.C. shunt motor will reduce slightly.

Answer : For the same H.P. rating and full load speed, following motor has poor starting torque differentially compounded.

Answer : The speed/load characteristics of a universal motor is same as that of D.C. series motor.

Answer : In A.C. series motor compensating winding is employed to reduce sparking at the brushes.

Answer : In split-phase motor auxiliary winding is of thin wire placed at the top of the slots.

Answer : In a capacitor start motor, the phase displacement between starting and running winding can be nearly 90°.

Answer : In a split phase motor, the running winding should have low resistance and high inductance.

Answer : A centrifugal switch is used to disconnect starting winding when motor has picked up about 50 to 70 per cent of rated speed.

Description : Why does the speed of a DC shunt motor decrease as the load increases?

Answer : Because if the load is increasing then the torque must also be increase. If not then the speed of motor will decrease.

Answer :  The size of a synchronous motor decreases with the increase in flux density.

Description : Explain with neat circuit diagrams the procedures to perform no load and blocked rotor tests on three phase induction motor.

Description : List different torques in synchronous motor. 

Answer : Different Torques in Synchronous Motor: 1) Starting torque 2) Running torque 3) Pull-in torque 4) Pull-out torque

Description : In a self-controlled synchronous motor fed from a variable frequency inverter  (1) the rotor poles invariably have damper windings  (2) there are stability problems  (3) the speed of the rotor decides stator frequency  (4) the frequency of the stator decides the rotor speed

Answer : In a self-controlled synchronous motor fed from a variable frequency inverter the frequency of the stator decides the rotor speed

← Prev Question Next Question →
editChoose topic
...