Explain the operation of full bridge converters with their different operating modes. State its advantages and disadvantages.

Please log in or register to answer this question.

1 Answer

Answer :

 
✔️✔️Best answer

Full bridge converter:

Full bridge converter provides isolation between input and output. Full bridge converter is used for step up or step down the input voltage. Full bridge converter consists of four power semiconductor switches, uncontrolled rectifier, a transformer with mid tap secondary, two diodes, and LC filter.

image

Advantages:

  • Smaller size
  • Lighter weight
  • Less sensitive to input voltage variation


Disadvantages:

  • Regulation is not very well.
  • Higher output ripple.
  • Require filter on both input and output.


Like 0 like

Related Questions

340 views

Description : Give the operation of single phase full wave bridge controlled converter with RL load with a neat diagram. Also draw its waveform.

Last Answer : Single phase fully control bridge converter with RL load: 1. During positive half cycle of input voltage, T1 and T2 are forward biased and during negative half cycle, T3 and T4 are forward biased. Therefore, T1-T2 ... cycle till the firing of next pair of SCRs as shown in the waveform.

1 answer
136 views

Description : A 230 V, 50 Hz phase controlled single-phase full-controlled SCR bridge converter draws 15 A constant dc current. If the source inductance is 3 mH, the drop in dc output voltage is (A) 4.5 V (B) 6.75 V (C) 9 V (D) 13.5 V

Last Answer : A 230 V, 50 Hz phase controlled single-phase full-controlled SCR bridge converter draws 15 A constant dc current. If the source inductance is 3 mH, the drop in dc output voltage is 9 V

1 answer
54 views

Description : Draw circuit diagram of symmetrical configuration of bridge converter.

Last Answer : circuit diagram of symmetrical configuration of bridge converter

1 answer
139 views

Description : In a 230 V, 50 Hz single-phase SCR bridge converter operating at a firing delay angle, α and with large R-L load, the input source current is (A) sinusoidal current (B) constant dc current (C) continuous rectangular pulses (D) alternating rectangular pulses

Last Answer : In a 230 V, 50 Hz single-phase SCR bridge converter operating at a firing delay angle, α and with large R-L load, the input source current is alternating rectangular pulses