99 views

Please log in or register to answer this question.

1 Answer

Answer :

Iron loss, copper loss and mechanical losses these are the losses in DC machine.
Like 0 like

Related Questions

105 views

Description : What is the percentage of stray losses in DC machine?

Last Answer : Percentage of stray losses in DC machine is about 1 % .

1 answer
133 views

Last Answer : Iron losses in a D.C. machine are independent of variations in load.

1 answer
163 views

Last Answer : Copper losses,iron losses,variable losses , constant losees

1 answer
121 views

Description : In DC motor iron losses are occurred in?

Last Answer : In DC motor iron losses are occurred in the armature.

1 answer
72 views

Description : Why poles of dc machine are laminated?

Last Answer : Poles of DC machines are laminated to reduce the eddy current losses in the poles.

1 answer
115 views

Description : The magnetic neutral plane shifts in a dc machine (A) in the direction of motion of motor (B) in the direction of motion of generator (C) due to increase in the field flux (D) cause reduction of flash over between commutator segments

Last Answer : The magnetic neutral plane shifts in a dc machine in the direction of motion of generator

1 answer
160 views

Description : Explain concept of back emf in DC machine. State how it governs armature current. 

Last Answer : Back emf: When the armature of DC machine rotates under the influence of driving torque, the armature conductors move in the magnetic field and cut it and hence emf is induced in them. The ... flow of armature current i.e. it automatically changes the armature current to meet load requirements.

1 answer
88 views

Description : A 200 V DC machine supplies 20 A at 200 V as a generator. The armature resistance is 0.2 Ohm. If the machine is now operated as a motor at same terminal voltage and current but with the flux increased by 10%, the ratio of motor speed to generator speed is

Last Answer : A 200 V DC machine supplies 20 A at 200 V as a generator. The armature resistance is 0.2 Ohm. If the machine is now operated as a motor at same terminal voltage and current but with the flux increased by 10%, the ratio of motor speed to generator speed is 0.87

1 answer
425 views

Description : A 36 slot, 4 -pole, dc machine has a simplex lap winding with two conductors per slot. The back pitch and front pitch adopted could be respectively

Last Answer : A 36 slot, 4 -pole, dc machine has a simplex lap winding with two conductors per slot. The back pitch and front pitch adopted could be respectively 19,17

1 answer
249 views

Description : The induced emf in the armature of a lap -wound four -pole dc machine having 100 armature conductors rotating at 600 rpm and with 1 Wb flux per pole is  (1) 1000V (2) 100V (3) 600V (4) 10,000V

Last Answer : The induced emf in the armature of a lap -wound four -pole dc machine having 100 armature conductors rotating at 600 rpm and with 1 Wb flux per pole is 1000V

1 answer
566 views

Description : Aluminium is not used as winding wire for the armature of a dc machine because  (1) aluminium has low resistivity (2) a large winding space is taken by aluminium conductors and creates ... ) the thermal conductivity of aluminium is low (4) aluminium has low conductivity as compared to copper

Last Answer : Aluminium is not used as winding wire for the armature of a dc machine because  (2) a large winding space is taken by aluminium conductors and creates jointing problems (3) the thermal conductivity of aluminium is low (4) aluminium has low conductivity as compared to copper