2 Answers

The three operating regions of BJT are cutoff region, active region, saturation region.
Like 0 like Dislike 0 dislike

Active , Saturation , Cut-off region of operations

in BJT.
Like 0 like Dislike 0 dislike

Related questions

Description : Operating frequency of power MOSFET is higher than that of power BJT. Justify the statement.

Answer : Power MOSFET have high turning on and turning off capability high switching speed of MOSFET is due to the high rate of change of drain voltage. The switching losses of power MOSFET ... lower frequency. Hence, operating frequency of power MOSFET is higher than that of power BJT.

Answer : In cut-off region of BJT both the emitter-base junction and collector-base junction are reverse biased.

Answer : Transformer coupled amplifiers Direct coupled amplifiers Multistage amplifiers Darlington amplifiers Emmiter follower

Answer : Bjt transistor is a type of transistor which  uses both electrons and hole charge carrier.bjts are used as switches and amplifiers.They amplify currents.

Description : What is a BJT?

Answer : Bipolar Junction Transistor (BJT): BJT is a Bipolar device. (Uses both electrons and holes charge carrier for current conduction) Two Junctions (Emitter junction & collector ... mode (Current amplification) Cutoff mode (Open switch) Saturation mode (Close switch)

Answer : The proper flow of zero signal collector current and the maintenance of the proper collector emmiter voltage during passage of single called as transistor biasing

Answer : Beta is the current gain which is the ratio of collector current to base current.

Answer : Bipolar junction transistor

Description : The command line interpreter that enables the users to interact with operating system is called the A) Window B) Shell C) Process D) Kernel 

Answer : The command line interpreter that enables the users to interact with operating system is called the Shell 

Description : An FET is a better chopper than a BJT because it has (A) lower offset voltage (B) higher series ON resistance (C) lower input current (D) higher input impedance

Answer : An FET is a better chopper than a BJT because it has lower offset voltage

Answer : Yes IGBT is costlier than BJT and MOSFET.

Answer : Yes BJT have internal capacitances.

Answer : BJT act as switch in saturation and  cutoff region ( ON state in saturation region and OFF state in cut-off region )

Answer : Active region of BJT act as amplifier.

Answer : Yes BJT have second breakdown problem.

Answer : BJT is current controlled device.

Answer : BJT have three terminals Base, emitter and collector.

Answer : In  BJT  there  is  movement  of   electrons  and  holes   accros  the  junctions  which  is  basicaly  current  flow.

Answer : When Q-point is at cut off region means it is just above the horizontal axis VCE

Answer : BJT control the flow of electron so it is a active device.

Answer : No, BJT is a current controlled device .

Description : A minimum clearance of 6.3 m to ground is required for overhead lines when operating voltages are :  (A) less than 66 kV (B) lie between 66 kV and 110 kV (C) more than 165 kV (D) lie between 110 kV and 165 kV

Answer : A minimum clearance of 6.3 m to ground is required for overhead lines when operating voltages are : lie between 66 kV and 110 kV

Answer : Operating torques in analogue instruments are deflecting, control and damping.

Description : What is the power factor when a single phase watt meter operating on 200 V and 5 A for 5 hours makes 2016 revolutions and the meter constant in revolution is 420? A) 0.04 B) 1.04 C) 0.96 D) None of these

Answer : What is the power factor when a single phase watt meter operating on 200 V and 5 A for 5 hours makes 2016 revolutions and the meter constant in revolution is 420? A) 0.04 B) 1.04 C) 0.96 D) None of these

Description : What is the difference between BJT and FET?

Answer : BJT  is  a  current  opperated   transistor  while  FET   is  a  field   opperated  transistor.

Description : What is a BJT amplifier?

Description : What is the difference between beta and forced beta for BJT?

Description : What is the value of Beta in power BJT?

Answer : The beta value in power BJT is 5 to 10.

Description :  operating principle of PUT.

Answer : Constructional diagram & Operating principle of PUT:  The PUT is a PNPN device similar to SCR, but its operation is similar to the UJT. The PUT behave like a UJT whose trigger voltage VP can be set ... low resistance and VAK ≈ 1V). The PUT is also referred to as a complementary SCR (CSCR). 

Description : Transistor operating configurations

Answer : Transistor operating configurations

Description : Draw construction of Megger and write operating principle of it.

Answer : Megger:  Working: Two coils the current coil and pressure coil are mounted at an angle on the same spindle and form the part of the moving system. These coils are connected to a small hand driven ... . When the instrument is not working the pointer may rest at any position on the dial.

Description : Explain the operating principle of LASER and list applications of LASER diode.

Answer : A basic construction of Laser diode is as shown . A PN junction is formed by two layers of doped gallium arsenide. There is highly reflective surface at one end of PN junction and ... 6. laser scanning and light beam illumination. 7. Military applications 8. Medical surgery 9.Diamond cutting

Description : The operating point of a protective current transformer is near the

Answer : The operating point of a protective current transformer is near the Ankle point

Description : The operating time of instantaneous relay is

Answer : The operating time of instantaneous relay is 0.1 sec

Description : In a single-phase induction motor, the operating direction is determined by the ________ A) Rotor B) Stator C) Starting circuit D) None of these

Answer : In a single-phase induction motor, the operating direction is determined by the Starting circuit

Description : The no-load speed of a single-phase SCR bridge converter fed separately excited dc motor operating at a firing delay angle, α and flux, Φ (A) directly proportional to α and Φ (B) ... proportional to α and inversely proportional to Φ (D) directly proportional to Φ and inversely proportional to α

Answer : The no-load speed of a single-phase SCR bridge converter fed separately excited dc motor operating at a firing delay angle, α and flux, Φ directly proportional to α and inversely proportional to Φ

Description : In a 230 V, 50 Hz single-phase SCR bridge converter operating at a firing delay angle, α and with large R-L load, the input source current is (A) sinusoidal current (B) constant dc current (C) continuous rectangular pulses (D) alternating rectangular pulses

Answer : In a 230 V, 50 Hz single-phase SCR bridge converter operating at a firing delay angle, α and with large R-L load, the input source current is alternating rectangular pulses

Description : Two synchronous generators operating in parallel supply a common load of 2.5 MW. The frequency-power characteristics have a common slope of 1 MW/Hz and the no-load frequencies of the generators are 51.5 Hz and 51.0 Hz, ... system frequency is (A) 50 Hz (B) 51 Hz (C) 51.25 Hz (D) 51.5 Hz

Answer : Two synchronous generators operating in parallel supply a common load of 2.5 MW. The frequency-power characteristics have a common slope of 1 MW/Hz and the no-load frequencies of the generators are 51.5 Hz and 51.0 Hz, respectively. Then the system frequency is 50 Hz

Description : A 230 V/460 V single-phase transformer operating at 20 A and unity power factor has primary referred resistance of 0.2 Ω and reactance of 0.5 Ω. The approximate primary induced emf is (A) 216 V (B) 226 V (C) 234 V (D) 236 V

Answer : A 230 V/460 V single-phase transformer operating at 20 A and unity power factor has primary referred resistance of 0.2 Ω and reactance of 0.5 Ω. The approximate primary induced emf is 226 V

Answer : The operating voltage of a meggar is about 100 V.

Answer : To limit the operating temperature an electrical machine should have proper current rating.

Answer : The operating speed of a synchronous motor can be changed to new fixed value by changing frequency.

Answer : Annual operating expenditure of a power plant consists of fixed charges, semi-fixed charges, running charges.

Answer : The relay operating speed depends upon the spring tension, the rate of flux built up, armature core air gap.

Description : The secondary of a current transformer is always short-circuited under operating conditions because it?

Answer : The secondary of a current transformer is always short-circuited under operating conditions because it avoids core saturation and high voltage induction.

Description : For a transformer, operating at constant load current, maximum efficiency will occur at?

Answer : For a transformer, operating at constant load current, maximum efficiency will occur at unity power factor.

Description : State 2 advantages of JFET over BJT.

Answer : Advantages of JFET over BJT: 1) High input impedance 2) Better thermal stability 3) Produce less noise 4) Smaller than BJT 5) Rugged in construction and simpler to fabricate 6) High degree of isolation between Input and Output. 

Description : List specification of BJT.

Answer : * The bipolar junction transistor (BJT) has small signal current gain, α (hfb). * Maximum collector current Ic (max). * Maximum collector to emitter voltage, VCE (max). * Collector to emitter ... . * Collector to emitter cut off voltage, VCEO. * Base emitter saturation voltage, VBE (sat).

Description : State reason BJT is called as bipolar junction transistor.

Answer : BJT is called bipolar junction transistor because in BJT current conduction takes place due to majority as well as minority charge carriers.

Description : List configurations of BJT. 

Answer : Configurations of BJT : 1) Common Base (CB) configuration 2) Common Emitter (CE) configuration 3) Common Collector (CC) configuration

← Prev Question Next Question →
Ask a Question